Bahram M. Shahrooz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bahram M. Shahrooz has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Kent A. Harries
Univ. of Pittsburgh
10 shared publications - Gian Andrea Rassati
University of Cincinnati
6 shared publications Henry G. Russell
Engineering Consultant, Henry G. Russell, Glenview, IL
3 shared publications- Patrick J. Fortney
Professor, Univ. of Michigan, Ann Arbor, MI 48109
3 shared publications - Richard A. Miller
Professor, Univ. of Cincinnati, Cincinnati, OH 45221. ORCID:
3 shared publications Amir Soltani
Ph.D. Candidate, Dept. of Civil and Environmental Engineering, Univ. of Pittsburgh, Pittsburgh, PA 15261
2 shared publications
Latest Publications
- 1 December 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 28 (12)
Performance Evaluation of Prestressed Girders with 17.8-mm (0.7-in.) Strands
- 1 December 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 28 (12)
Performance Evaluation of Prestressed Girders with 17.8-mm (0.7-in.) Strands
- 28 April 2023
- Published by The National Academies Press
Guidelines for Adjacent Precast Concrete Box Beam Bridge Systems
Download a PDF of "Guidelines for Adjacent Precast Concrete Box Beam Bridge Systems" by the National Academies of Sciences, Engineering, and Medicine for free.
- 28 April 2023
- Published by The National Academies Press
Guidelines for Adjacent Precast Concrete Box Beam Bridge Systems
Download a PDF of "Guidelines for Adjacent Precast Concrete Box Beam Bridge Systems" by the National Academies of Sciences, Engineering, and Medicine for free.
- 1 November 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 26 (11) , 07021002
Closure to “Evaluation of Pretensioned Girders with Partial-Strand Debonding” by Mathew W. Bolduc, Avdhesh Gaur, Bahram M. Shahrooz, Kent A. Harries, Richard A. Miller, and Henry G. Russell
Sponsored by the Structural Engineering Institute
- 1 November 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 26 (11) , 07021002
Closure to “Evaluation of Pretensioned Girders with Partial-Strand Debonding” by Mathew W. Bolduc, Avdhesh Gaur, Bahram M. Shahrooz, Kent A. Harries, Richard A. Miller, and Henry G. Russell
Sponsored by the Structural Engineering Institute
- 1 August 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 25 (8) , 04020059
Evaluation of Pretensioned Girders with Partial-Strand Debonding
Pretensioned concrete girders—especially those having large prestress forces—are susceptible to flexural cracking at their top flanges near the girder end as a result of prestress transfer. One effective method to reduce such extreme-fiber stresses is to partially debond some of the strands. The 2017 edition of AASHTO LRFD Bridge Design Specifications provides limits on the number of strands that can be debonded at a given location and in each row of strands. The limits are attributed to an experimental study in which the test specimens were designed under the previous AASHTO Standard Specifications. Some states have allowed the AASHTO limits to be exceeded, while others have adhered to the limits. National Cooperative Highway Research Program Project 12-91 Strand Debonding for Pretensioned Girders was initiated to develop a unified approach to the design of partially debonded strand details in prestressed concrete bridge girders. Detailed design case studies and synthesis of experimental data suggest that the debonding ratio is not a sufficient metric by itself to gauge the performance and capacity of prestressed concrete girders. Despite having a greater extent of debonding than the 2017 AASHTO limits, girders meeting the requirements for shear and longitudinal reinforcement in end regions are expected to perform adequately in terms of strength, deformability, stiffness, crack widths, and modes of failure.
- 1 August 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 25 (8) , 04020059
Evaluation of Pretensioned Girders with Partial-Strand Debonding
Pretensioned concrete girders—especially those having large prestress forces—are susceptible to flexural cracking at their top flanges near the girder end as a result of prestress transfer. One effective method to reduce such extreme-fiber stresses is to partially debond some of the strands. The 2017 edition of AASHTO LRFD Bridge Design Specifications provides limits on the number of strands that can be debonded at a given location and in each row of strands. The limits are attributed to an experimental study in which the test specimens were designed under the previous AASHTO Standard Specifications. Some states have allowed the AASHTO limits to be exceeded, while others have adhered to the limits. National Cooperative Highway Research Program Project 12-91 Strand Debonding for Pretensioned Girders was initiated to develop a unified approach to the design of partially debonded strand details in prestressed concrete bridge girders. Detailed design case studies and synthesis of experimental data suggest that the debonding ratio is not a sufficient metric by itself to gauge the performance and capacity of prestressed concrete girders. Despite having a greater extent of debonding than the 2017 AASHTO limits, girders meeting the requirements for shear and longitudinal reinforcement in end regions are expected to perform adequately in terms of strength, deformability, stiffness, crack widths, and modes of failure.
- 1 April 2018
- Published by Elsevier in Engineering Structures
- Vol. 160, 111-120
Seismic performance of reinforce concrete buildings designed according to codes in Bangladesh, India and U.S.
- 1 April 2018
- Published by Elsevier in Engineering Structures
- Vol. 160, 111-120
Seismic performance of reinforce concrete buildings designed according to codes in Bangladesh, India and U.S.
- 1 February 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (2)
Steel Coupling Beams with a Replaceable Fuse
Steel coupling beams have emerged as a viable alternative to conventionally and diagonally reinforced concrete coupling beams because of their superior energy-dissipation characteristics, smaller member depth, and ease of construction, to name but a few advantages. Conventional steel coupling beams are designed to yield under design-level ground motions; hence, postevent repair requires replacement of the entire beam that is embedded into wall piers and interfaced with a significant amount of wall pier reinforcement. Such a repair will be costly, intrusive, and very likely impractical. A new system involving a replaceable midspan fuse located in the coupling beam was developed. In this system, the fuse acts as the primary energy-dissipating component, while the remainder of the beam span and its embedments into the wall piers remain elastic when the building is subjected to design-level ground motions. Hence, it is only necessary to replace the accessible damaged fuses since the rest of the beam and wall piers remain undamaged. This paper presents a design methodology for using steel coupling beams that have a replaceable fuse. Laboratory test data were found to validate the methodology. A 20-story prototype building was designed according to the proposed methodology and results from nonlinear static and dynamic analyses indicate that the building performed according to the objectives of the presented design methodology. That is, (1) the midspan fuses are the primary energy-dissipating components; (2) the fuses develop their capacity before the embedded beams reach their expected shear or elastic flexural capacities; (3) the wall piers experience little or no damage under design ground motions; (4) the wall piers maintain their integrity for maximum credible ground motions; and (5) residual deformations are small, permitting new fuses to be installed following design-level ground motions.
- 1 February 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (2)
Steel Coupling Beams with a Replaceable Fuse
Steel coupling beams have emerged as a viable alternative to conventionally and diagonally reinforced concrete coupling beams because of their superior energy-dissipation characteristics, smaller member depth, and ease of construction, to name but a few advantages. Conventional steel coupling beams are designed to yield under design-level ground motions; hence, postevent repair requires replacement of the entire beam that is embedded into wall piers and interfaced with a significant amount of wall pier reinforcement. Such a repair will be costly, intrusive, and very likely impractical. A new system involving a replaceable midspan fuse located in the coupling beam was developed. In this system, the fuse acts as the primary energy-dissipating component, while the remainder of the beam span and its embedments into the wall piers remain elastic when the building is subjected to design-level ground motions. Hence, it is only necessary to replace the accessible damaged fuses since the rest of the beam and wall piers remain undamaged. This paper presents a design methodology for using steel coupling beams that have a replaceable fuse. Laboratory test data were found to validate the methodology. A 20-story prototype building was designed according to the proposed methodology and results from nonlinear static and dynamic analyses indicate that the building performed according to the objectives of the presented design methodology. That is, (1) the midspan fuses are the primary energy-dissipating components; (2) the fuses develop their capacity before the embedded beams reach their expected shear or elastic flexural capacities; (3) the wall piers experience little or no damage under design ground motions; (4) the wall piers maintain their integrity for maximum credible ground motions; and (5) residual deformations are small, permitting new fuses to be installed following design-level ground motions.
- 18 February 2016
- Published by American Society of Civil Engineers (ASCE)
- p. 494-507
The Development of a Steel Fuse Coupling Beam for Coupled Core Wall Systems
Coupled core wall systems are being used in seismically active areas worldwide as an effective type of structural system for resisting earthquake demands. At the University of Cincinnati, the design evolution of an innovative type of steel coupling beam was investigated that provides a significant advantage for structures utilizing linked concrete walls. The concept of post-event reparability can be realized through the use of a steel coupling beam in which a weak-link, or ‘fuse’ section is induced at the center of the clear span of the beam. During extreme seismic events on a fused coupled core wall system, all inelastic response is focused onto the weak link while the elastic integrity of the surrounding embedded beams and walls is ensured by careful detailing. A code-compliant design procedure has been established that preserves the intended performance. Results and conclusions from the analytical modeling of a 20-story structure indicate that steel fuse coupling beams perform favorably in a seismic event. Data from experimental tests demonstrate the adequacy of the design procedure and show the performance under cyclic load demands.
- 18 February 2016
- Published by American Society of Civil Engineers (ASCE)
- p. 494-507
The Development of a Steel Fuse Coupling Beam for Coupled Core Wall Systems
Coupled core wall systems are being used in seismically active areas worldwide as an effective type of structural system for resisting earthquake demands. At the University of Cincinnati, the design evolution of an innovative type of steel coupling beam was investigated that provides a significant advantage for structures utilizing linked concrete walls. The concept of post-event reparability can be realized through the use of a steel coupling beam in which a weak-link, or ‘fuse’ section is induced at the center of the clear span of the beam. During extreme seismic events on a fused coupled core wall system, all inelastic response is focused onto the weak link while the elastic integrity of the surrounding embedded beams and walls is ensured by careful detailing. A code-compliant design procedure has been established that preserves the intended performance. Results and conclusions from the analytical modeling of a 20-story structure indicate that steel fuse coupling beams perform favorably in a seismic event. Data from experimental tests demonstrate the adequacy of the design procedure and show the performance under cyclic load demands.
- 1 September 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 17 (5) , 804-812
Flexural Crack Widths in Concrete Girders with High-Strength Reinforcement
The introduction of steel reinforcing bars having yield strengths exceeding 517 MPa (75 ksi) and often approaching 827 MPa (120 ksi) may allow for significant economies to be realized, particularly when used in conjunction with high-strength concrete. One implication of the adoption of higher-strength reinforcing steel is that reinforcing bar stresses (and therefore strains and consequently crack widths) at service load levels are expected to be greater than when conventional bars [having a yield of 414 MPa (60 ksi)] are used. A study of flexural crack widths of beams reinforced with high-strength ASTM A1035 reinforcing steel is presented. Discussion focuses on the behavior at loads corresponding to longitudinal reinforcing bar stresses of 248, 414, and 496 MPa (36, 60, and 72 ksi), representing service load levels (i.e., 0.6fy) for steel having fy = 414,690, and 827 MPa (60, 100, and 120 ksi), respectively. Average measured crack widths obtained from a series of flexural beams having reinforcing ...
- 1 September 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 17 (5) , 804-812
Flexural Crack Widths in Concrete Girders with High-Strength Reinforcement
The introduction of steel reinforcing bars having yield strengths exceeding 517 MPa (75 ksi) and often approaching 827 MPa (120 ksi) may allow for significant economies to be realized, particularly when used in conjunction with high-strength concrete. One implication of the adoption of higher-strength reinforcing steel is that reinforcing bar stresses (and therefore strains and consequently crack widths) at service load levels are expected to be greater than when conventional bars [having a yield of 414 MPa (60 ksi)] are used. A study of flexural crack widths of beams reinforced with high-strength ASTM A1035 reinforcing steel is presented. Discussion focuses on the behavior at loads corresponding to longitudinal reinforcing bar stresses of 248, 414, and 496 MPa (36, 60, and 72 ksi), representing service load levels (i.e., 0.6fy) for steel having fy = 414,690, and 827 MPa (60, 100, and 120 ksi), respectively. Average measured crack widths obtained from a series of flexural beams having reinforcing ...
- 1 May 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 17 (3) , 454-461
Fatigue Performance of High-Strength Reinforcing Steel
An evaluation of concrete reinforcing bar fatigue provisions of AASHTO LRFD Bridge Design Specifications as they pertain to the use of high-strength reinforcing steel is presented. Two large-scale proof tests and a review of available published data demonstrate that presently accepted values for the fatigue or endurance limit for reinforcing steel are applicable, and likely conservative, when applied to higher-strength bars. A minor revision to the AASHTO specification is proposed to eliminate the fatigue penalty resulting from the use of higher-strength reinforcing steel. Finally, it is shown that fatigue considerations will rarely affect the design of typical reinforced-concrete members having a specified yield strength, .- 1 May 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 17 (3) , 454-461
Fatigue Performance of High-Strength Reinforcing Steel
An evaluation of concrete reinforcing bar fatigue provisions of AASHTO LRFD Bridge Design Specifications as they pertain to the use of high-strength reinforcing steel is presented. Two large-scale proof tests and a review of available published data demonstrate that presently accepted values for the fatigue or endurance limit for reinforcing steel are applicable, and likely conservative, when applied to higher-strength bars. A minor revision to the AASHTO specification is proposed to eliminate the fatigue penalty resulting from the use of higher-strength reinforcing steel. Finally, it is shown that fatigue considerations will rarely affect the design of typical reinforced-concrete members having a specified yield strength, .- 25 February 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 479-492
Performance Evaluation of Innovative Hybrid Coupled Core Wall Systems
The paper presents an ongoing investigation of the cyclic performance of steel coupling beams in hybrid coupled core wall systems. Coupled core wall systems offer remarkable lateral strength and stiffness, and taking advantage of the favorable cyclic behavior of steel coupling beams makes the best use of all materials employed. Moreover, the inherent characteristics of the systems considered are ideal for an application of performance-based design approaches. Preliminary results are discussed from the standpoint of seismic performance, demonstrating the advantages of steel coupling beams and innovative details of coupling beams, conceived with reparability in mind, are presented. The design of a prototype structure is discussed, and a two-phase experimental campaign is described. It is anticipated that a hybrid, pseudo-dynamic analysis of the coupled core wall systems considered will show that the use of steel coupling beams in a performance-based design framework can deliver economical and safe structures with remarkable strength, stiffness, and ductility.
- 25 February 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 479-492
Performance Evaluation of Innovative Hybrid Coupled Core Wall Systems
The paper presents an ongoing investigation of the cyclic performance of steel coupling beams in hybrid coupled core wall systems. Coupled core wall systems offer remarkable lateral strength and stiffness, and taking advantage of the favorable cyclic behavior of steel coupling beams makes the best use of all materials employed. Moreover, the inherent characteristics of the systems considered are ideal for an application of performance-based design approaches. Preliminary results are discussed from the standpoint of seismic performance, demonstrating the advantages of steel coupling beams and innovative details of coupling beams, conceived with reparability in mind, are presented. The design of a prototype structure is discussed, and a two-phase experimental campaign is described. It is anticipated that a hybrid, pseudo-dynamic analysis of the coupled core wall systems considered will show that the use of steel coupling beams in a performance-based design framework can deliver economical and safe structures with remarkable strength, stiffness, and ductility.