Latest Publications

  • Open Access

    Caval vein obstruction resulting in right to left shunt and desaturation post–endocardial pacing implantation in a 3-year old: a case report

    by Emma Poffley, Kristian Mortensen, Luke Starling, Jasveer Mangat, Jan Marek

    Background: Superior caval vein obstruction is a rare complication of endocardial pacing lead implantation that can result in a right to left shunt. Case summary: A 3-year-old child with type 2 Brugada syndrome presented with mild cyanosis post–endocardial pacing implantation due to evolutionary right superior caval vein obstruction. This obstruction resulted in a right to left shunt across a previously unrecognized patent levo-atrial cardinal vein associated with partial anomalous pulmonary venous drainage. The patient underwent endocardial pacing explantation, balloon dilation and stenting of the right superior caval vein, banding of the levo-atrial cardinal vein to left upper pulmonary vein venous channel, and implantation of an epicardial pacing system. Discussion: Levo-atrial cardinal vein and partial anomalous pulmonary venous drainage with dual drainage can go undetected on cardiac imaging and may not ever cause symptoms (high left-to-right shunt or cyanosis). The levo-atrial cardinal vein and associated partial anomalous venous drainage with dual drainage was missed on multiple occasions and with multiple imaging modalities in our patient. Blood flow may not be detected in a small calibre or collapsed levo-atrial cardinal vein with pulmonary venous connection when the pulmonary vein remains widely patent and connected to the left atrium. Detailed comprehensive echocardiography of any child referred for cardiac intervention should include pulsed wave Doppler and colour flow mapping interrogation of the innominate vein from the suprasternal approach.

  • Open Access

    App-Based Versus Standard Six-Minute Walk Test in Pulmonary Hypertension: Mixed Methods Study

    by Dario Salvi, Emma Poffley, Lionel Tarassenko, Elizabeth Orchard

    Background: Pulmonary arterial hypertension (PAH) is a chronic disease of the pulmonary vasculature that can lead to heart failure and premature death. Assessment of patients with PAH includes performing a 6-minute walk test (6MWT) in clinics. We developed a smartphone app to compute the walked distance (6MWD) indoors, by counting U-turns, and outdoors, by using satellite positioning. Objective: The goal of the research was to assess (1) accuracy of the indoor 6MWTs in clinical settings, (2) validity and test-retest reliability of outdoor 6MWTs in the community, (3) compliance, usability, and acceptance of the app, and (4) feasibility of pulse oximetry during 6MWTs. Methods: We tested the app on 30 PAH patients over 6 months. Patients were asked to perform 3 conventional 6MWTs in clinic while using the app in the indoor mode and one or more app-based 6MWTs in outdoor mode in the community per month. Results: Bland-Altman analysis of 70 pairs of conventional versus app-based indoor 6MWDs suggests that the app is sometimes inaccurate (14.6 m mean difference, lower and upper limit of agreement: –133.35 m to 162.55 m). The comparison of 69 pairs of conventional 6MWDs and community-based outdoor 6MWDs within 7 days shows that community tests are strongly related to those performed in clinic (correlation 0.89), but the interpretation of the distance should consider that differences above the clinically significant threshold are not uncommon. Analysis of 89 pairs of outdoor tests performed by the same patient within 7 days shows that community-based tests are repeatable (intraclass correlation 0.91, standard error of measurement 36.97 m, mean coefficient of variation 12.45%). Questionnaires and semistructured interviews indicate that the app is usable and well accepted, but motivation to use it could be affected if the data are not used for clinical decision, which may explain low compliance in 52% of our cohort. Analysis of pulse oximetry data indicates that conventional pulse oximeters are unreliable if used during a walk. Conclusions: App-based outdoor 6MWTs in community settings are valid, repeatable, and well accepted by patients. More studies would be needed to assess the benefits of using the app in clinical practice. Trial Registration: ClinicalTrials.gov NCT04633538; https://clinicaltrials.gov/ct2/show/NCT04633538


  • Open Access

    App-Based Versus Standard Six-Minute Walk Test in Pulmonary Hypertension: Mixed Methods Study (Preprint)

    by Dario Salvi, Emma Poffley, Lionel Tarassenko, Elizabeth Orchard

    BACKGROUND Pulmonary arterial hypertension (PAH) is a chronic disease of the pulmonary vasculature that can lead to heart failure and premature death. Assessment of patients with PAH includes performing a 6-minute walk test (6MWT) in clinics. We developed a smartphone app to compute the walked distance (6MWD) indoors, by counting U-turns, and outdoors, by using satellite positioning. OBJECTIVE The goal of the research was to assess (1) accuracy of the indoor 6MWTs in clinical settings, (2) validity and test-retest reliability of outdoor 6MWTs in the community, (3) compliance, usability, and acceptance of the app, and (4) feasibility of pulse oximetry during 6MWTs. METHODS We tested the app on 30 PAH patients over 6 months. Patients were asked to perform 3 conventional 6MWTs in clinic while using the app in the indoor mode and one or more app-based 6MWTs in outdoor mode in the community per month. RESULTS Bland-Altman analysis of 70 pairs of conventional versus app-based indoor 6MWDs suggests that the app is sometimes inaccurate (14.6 m mean difference, lower and upper limit of agreement: –133.35 m to 162.55 m). The comparison of 69 pairs of conventional 6MWDs and community-based outdoor 6MWDs within 7 days shows that community tests are strongly related to those performed in clinic (correlation 0.89), but the interpretation of the distance should consider that differences above the clinically significant threshold are not uncommon. Analysis of 89 pairs of outdoor tests performed by the same patient within 7 days shows that community-based tests are repeatable (intraclass correlation 0.91, standard error of measurement 36.97 m, mean coefficient of variation 12.45%). Questionnaires and semistructured interviews indicate that the app is usable and well accepted, but motivation to use it could be affected if the data are not used for clinical decision, which may explain low compliance in 52% of our cohort. Analysis of pulse oximetry data indicates that conventional pulse oximeters are unreliable if used during a walk. CONCLUSIONS App-based outdoor 6MWTs in community settings are valid, repeatable, and well accepted by patients. More studies would be needed to assess the benefits of using the app in clinical practice. CLINICALTRIAL ClinicalTrials.gov NCT04633538; https://clinicaltrials.gov/ct2/show/NCT04633538

  • Open Access

    The Mobile-Based 6-Minute Walk Test: Usability Study and Algorithm Development and Validation

    by Dario Salvi, Emma Poffley, Elizabeth Orchard, Lionel Tarassenko

    Background: The 6-min walk test (6MWT) is a convenient method for assessing functional capacity in patients with cardiopulmonary conditions. It is usually performed in the context of a hospital clinic and thus requires the involvement of hospital staff and facilities, with their associated costs. Objective: This study aimed to develop a mobile phone–based system that allows patients to perform the 6MWT in the community. Methods: We developed 2 algorithms to compute the distance walked during a 6MWT using sensors embedded in a mobile phone. One algorithm makes use of the global positioning system to track the location of the phone when outdoors and hence computes the distance travelled. The other algorithm is meant to be used indoors and exploits the inertial sensors built into the phone to detect U-turns when patients walk back and forth along a corridor of fixed length. We included these algorithms in a mobile phone app, integrated with wireless pulse oximeters and a back-end server. We performed Bland-Altman analysis of the difference between the distances estimated by the phone and by a reference trundle wheel on 49 indoor tests and 30 outdoor tests, with 11 different mobile phones (both Apple iOS and Google Android operating systems). We also assessed usability aspects related to the app in a discussion group with patients and clinicians using a technology acceptance model to guide discussion. Results: The mean difference between the mobile phone-estimated distances and the reference values was −2.013 m (SD 7.84 m) for the indoor algorithm and −0.80 m (SD 18.56 m) for the outdoor algorithm. The absolute maximum difference was, in both cases, below the clinically significant threshold. A total of 2 pulmonary hypertension patients, 1 cardiologist, 2 physiologists, and 1 nurse took part in the discussion group, where issues arising from the use of the 6MWT in hospital were identified. The app was demonstrated to be usable, and the 2 patients were keen to use it in the long term. Conclusions: The system described in this paper allows patients to perform the 6MWT at a place of their convenience. In addition, the use of pulse oximetry allows more information to be generated about the patient’s health status and, possibly, be more relevant to the real-life impact of their condition. Preliminary assessment has shown that the developed 6MWT app is highly accurate and well accepted by its users. Further tests are needed to assess its clinical value.


  • Open Access

    The Mobile-Based 6-Minute Walk Test: Usability Study and Algorithm Development and Validation (Preprint)

    by Dario Salvi, Emma Poffley, Elizabeth Orchard, Lionel Tarassenko

    BACKGROUND The 6-min walk test (6MWT) is a convenient method for assessing functional capacity in patients with cardiopulmonary conditions. It is usually performed in the context of a hospital clinic and thus requires the involvement of hospital staff and facilities, with their associated costs. OBJECTIVE This study aimed to develop a mobile phone–based system that allows patients to perform the 6MWT in the community. METHODS We developed 2 algorithms to compute the distance walked during a 6MWT using sensors embedded in a mobile phone. One algorithm makes use of the global positioning system to track the location of the phone when outdoors and hence computes the distance travelled. The other algorithm is meant to be used indoors and exploits the inertial sensors built into the phone to detect U-turns when patients walk back and forth along a corridor of fixed length. We included these algorithms in a mobile phone app, integrated with wireless pulse oximeters and a back-end server. We performed Bland-Altman analysis of the difference between the distances estimated by the phone and by a reference trundle wheel on 49 indoor tests and 30 outdoor tests, with 11 different mobile phones (both Apple iOS and Google Android operating systems). We also assessed usability aspects related to the app in a discussion group with patients and clinicians using a technology acceptance model to guide discussion. RESULTS The mean difference between the mobile phone-estimated distances and the reference values was −2.013 m (SD 7.84 m) for the indoor algorithm and −0.80 m (SD 18.56 m) for the outdoor algorithm. The absolute maximum difference was, in both cases, below the clinically significant threshold. A total of 2 pulmonary hypertension patients, 1 cardiologist, 2 physiologists, and 1 nurse took part in the discussion group, where issues arising from the use of the 6MWT in hospital were identified. The app was demonstrated to be usable, and the 2 patients were keen to use it in the long term. CONCLUSIONS The system described in this paper allows patients to perform the 6MWT at a place of their convenience. In addition, the use of pulse oximetry allows more information to be generated about the patient’s health status and, possibly, be more relevant to the real-life impact of their condition. Preliminary assessment has shown that the developed 6MWT app is highly accurate and well accepted by its users. Further tests are needed to assess its clinical value.