Krzysztof Siwiec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Krzysztof Siwiec has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Witold A. Pleskacz
16 shared publicationsTomasz Borejko
7 shared publicationsJakub Kopanski
Institute of Microelectronics & Optoelectronics, Warsaw University of Technology, ul. Koszykowa 75, 00-662, POLAND
6 shared publicationsAdam Jarosz
Department of Integrated Circuits and Systems Design, Instytut Technologii Elektronowej, POLAND, Warsaw
3 shared publicationsEwa Kurjata-Pfitzner
Department of Integrated Circuits and Systems Design, Instytut Technologii Elektronowej, POLAND, Warsaw
3 shared publicationsPawel Narczyk
Institute of Microelectronics & Optoelectronics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warszawa, Poland
3 shared publications
Latest Publications
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-4
Design of a True Random Number Generator Based on Low Power Oscillator with Increased Jitter
This paper presents the design of an oscillator-based true random number generator. The operation of the presented TRNG architecture is based on sampling a high-frequency oscillator output with a clock generated by a low-frequency noisy oscillator. The recycling folded cascode architecture was used for low power noise amplifier. A new method to achieve higher jitter in the low frequency oscillator is presented. The bit rate of the designed TRNG is 1.02 Mb/s. The circuit power consumption is 67 μW. The results of the simulations and statistical tests of the designed random number generator are also presented in this paper.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 1-4
Design of a True Random Number Generator Based on Low Power Oscillator with Increased Jitter
This paper presents the design of an oscillator-based true random number generator. The operation of the presented TRNG architecture is based on sampling a high-frequency oscillator output with a clock generated by a low-frequency noisy oscillator. The recycling folded cascode architecture was used for low power noise amplifier. A new method to achieve higher jitter in the low frequency oscillator is presented. The bit rate of the designed TRNG is 1.02 Mb/s. The circuit power consumption is 67 μW. The results of the simulations and statistical tests of the designed random number generator are also presented in this paper.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 113-116
2.4 GHz LC-VCO with Improved Robustness against PVT Using FD-SOI Body Biasing Technique
This paper presents the application of FD-SOI body-biasing technique to improve robustness against PVT of an LC-tank voltage controlled oscillator (VCO). Designed VCO operates at 2.4 GHz ISM band and achieves phase noise level below -109.6 dBc/Hz. Power consumption equals 2.805 mW in the worst case. 28 nm FD-SOI process has been used.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 113-116
2.4 GHz LC-VCO with Improved Robustness against PVT Using FD-SOI Body Biasing Technique
This paper presents the application of FD-SOI body-biasing technique to improve robustness against PVT of an LC-tank voltage controlled oscillator (VCO). Designed VCO operates at 2.4 GHz ISM band and achieves phase noise level below -109.6 dBc/Hz. Power consumption equals 2.805 mW in the worst case. 28 nm FD-SOI process has been used.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 328-332
Temperature calibration technique based on on-chip resistor
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 328-332
Temperature calibration technique based on on-chip resistor
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 398-403
Importance of on-chip inductor modeling in radio frequency integrated circuits
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 398-403
Importance of on-chip inductor modeling in radio frequency integrated circuits
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 67-72
Analog front-end for precise human body temperature measurement
Analog front-end for precise temperature measurement of a human body has been presented. The discussed analog front-end (AFE) contains a new temperature calibration technique based on on-chip resistor. The described calibration method allows to obtain very high accuracy, even 0.1 °C, in very wide range of an operating temperature of an integrated circuit. The AFE consists of a bandgap current reference, a precision current source, a programmable gain amplifier, a voltage source proportional to absolute temperature and on-chip temperature calibration resistor. The presented analog front-end consumes no more than 180 uW and was designed and manufactured in UMC CMOS 130 nm technology. All data presented in the article were obtained from measurements. Measurements were taken using manual wafer prober with climate control microchamber, at temperature range from -40 °C to 125 °C.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 67-72
Analog front-end for precise human body temperature measurement
Analog front-end for precise temperature measurement of a human body has been presented. The discussed analog front-end (AFE) contains a new temperature calibration technique based on on-chip resistor. The described calibration method allows to obtain very high accuracy, even 0.1 °C, in very wide range of an operating temperature of an integrated circuit. The AFE consists of a bandgap current reference, a precision current source, a programmable gain amplifier, a voltage source proportional to absolute temperature and on-chip temperature calibration resistor. The presented analog front-end consumes no more than 180 uW and was designed and manufactured in UMC CMOS 130 nm technology. All data presented in the article were obtained from measurements. Measurements were taken using manual wafer prober with climate control microchamber, at temperature range from -40 °C to 125 °C.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 448-451
Design and measurements of the specialized VLSI circuit for blood oxygen saturation monitoring
In this paper the specialized chip for pulse oximetry measurements is presented. It has been developed as a part of the system for human vital signs monitoring. It allows a non-invasive measurement of blood oxygen saturation basing on the difference in light absorption coefficient for oxygenated and deoxygenated blood (oximetry). The chip has been fabricated in UMC 130nm technology. Measurement results proved proper operation of the designed structure.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 448-451
Design and measurements of the specialized VLSI circuit for blood oxygen saturation monitoring
In this paper the specialized chip for pulse oximetry measurements is presented. It has been developed as a part of the system for human vital signs monitoring. It allows a non-invasive measurement of blood oxygen saturation basing on the difference in light absorption coefficient for oxygenated and deoxygenated blood (oximetry). The chip has been fabricated in UMC 130nm technology. Measurement results proved proper operation of the designed structure.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 130-135
A low sampling frequency switched capacitor low-pass filter for wireless receivers
This paper presents a low-pass filter with variable gain for use in direct conversion wireless receivers. The filter is implemented using the switched-capacitor technique. Its sampling clock frequency is, however, only moderately higher than signal frequencies of interest. To cope with the problems that this creates, a new set of design equations are derived, from analytically calculated filter transfer function in Z domain. Circuit implementation is shown and its electrical simulation results, both schematic and post-layout are presented.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 130-135
A low sampling frequency switched capacitor low-pass filter for wireless receivers
This paper presents a low-pass filter with variable gain for use in direct conversion wireless receivers. The filter is implemented using the switched-capacitor technique. Its sampling clock frequency is, however, only moderately higher than signal frequencies of interest. To cope with the problems that this creates, a new set of design equations are derived, from analytically calculated filter transfer function in Z domain. Circuit implementation is shown and its electrical simulation results, both schematic and post-layout are presented.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Precision human body temperature measurement based on thermistor sensor
An analog front-end, with a new temperature calibration method, for an accurate temperature measurement of a human body has been presented. The discussed AFE consists of a current reference, a precision current source, a programmable gain amplifier, a voltage source proportional to absolute temperature and on-chip temperature calibration resistor. Human body temperature can be measured in the range from +25 °C to +45 °C at the operating temperature of an IC in the range from -40 °C to +125 °C with 0.1 °C precision. The presented analog front-end consumes no more than 180 uW and was designed in UMC CMOS 130 nm technology.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Precision human body temperature measurement based on thermistor sensor
An analog front-end, with a new temperature calibration method, for an accurate temperature measurement of a human body has been presented. The discussed AFE consists of a current reference, a precision current source, a programmable gain amplifier, a voltage source proportional to absolute temperature and on-chip temperature calibration resistor. Human body temperature can be measured in the range from +25 °C to +45 °C at the operating temperature of an IC in the range from -40 °C to +125 °C with 0.1 °C precision. The presented analog front-end consumes no more than 180 uW and was designed in UMC CMOS 130 nm technology.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 54, 1-6
BioSoC: Highly integrated System-on-Chip for health monitoring
The BioSoC is a highly integrated SoC that consists of analog front-ends, analog to digital converters and a 32-bit microcontroller - Adelite. The designed IC allows for dynamic acquisition and processing of the most important human physiological parameters. The provided analog interfaces to external electrodes and sensors allow measurement of electrocardiograms (ECG), electromyograms (EMG), skin temperature and resistance, and respiration rate (RR). After analog processing signals are sampled and digitized in analog-to-digital converters they can be further processed in a 32-bit microcontroller Adelite. The clock frequency of the microprocessor core is configurable from 32 kHz up to 16 MHz. The microcontroller is equipped with many digital interfaces and peripherals, such as 2×UART and 2×SPI with DMA channels, 16 GPIOs and 5 timers along with RTC. The BioSoC makes it possible to build highly integrated devices with rich functionalities in the area of telemedicine that respond to the growing demand for portable health monitoring. The BioSoC was designed and fabricated in UMC CMOS 130 nm technology process and occupies the area of 25mm 2 .
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 54, 1-6
BioSoC: Highly integrated System-on-Chip for health monitoring
The BioSoC is a highly integrated SoC that consists of analog front-ends, analog to digital converters and a 32-bit microcontroller - Adelite. The designed IC allows for dynamic acquisition and processing of the most important human physiological parameters. The provided analog interfaces to external electrodes and sensors allow measurement of electrocardiograms (ECG), electromyograms (EMG), skin temperature and resistance, and respiration rate (RR). After analog processing signals are sampled and digitized in analog-to-digital converters they can be further processed in a 32-bit microcontroller Adelite. The clock frequency of the microprocessor core is configurable from 32 kHz up to 16 MHz. The microcontroller is equipped with many digital interfaces and peripherals, such as 2×UART and 2×SPI with DMA channels, 16 GPIOs and 5 timers along with RTC. The BioSoC makes it possible to build highly integrated devices with rich functionalities in the area of telemedicine that respond to the growing demand for portable health monitoring. The BioSoC was designed and fabricated in UMC CMOS 130 nm technology process and occupies the area of 25mm 2 .