Chengke Zhoua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengke Zhoua has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Defu Cai
State Grid Hubei Electric Power Research Institute, Wuhan 430064, China
1 shared publication - Fan Yang
Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan, 430077, China
1 shared publication - Kan Cao
Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan, 430077, China
1 shared publication - Kunpeng Zhoua
Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan, 430077, China
1 shared publication - Yu Shen
Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan, 430077, China
1 shared publication - Zeyang Tang
State Grid Hubei Electric Power Research Institute, Wuhan 430077, China
1 shared publication
Latest Publications
- Open Access
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 79408-79418
A Dimension Reduction Method Used in Detecting Errors of Distribution Transformer Connectivity
Many power utilities may have problems with the quality of data in records about which feeder a distribution transformer is connected to. This affects the operation and maintenance of smart grid infrastructure, outage management, line loss management, and workforce safety. The traditional manual way of verifying and updating the distribution transformer connectivity (DTC) is time-consuming and labor-intensive. Researchers have proposed the method which makes use of secondary side single-phase voltage of distribution transformers to verify DTC. However, when the windings of distribution transformers are yyn0 connected, the performance of the single-phase voltage method (SPVM) is unsatisfactory due to the unbalanced three-phase voltages. This paper proposed a dimension reduction method (DRM) that can convert the unbalanced three-phase voltage to a balanced voltage. The data which include 29 days’ secondary side voltages of 3866 distribution transformers have been collected. The performances of the DRM and the SPVM have been compared. Results show that the DRM always has higher accuracy compared with SPVM. The influences of the maximum voltage difference and the reference distribution transformer have also been discussed. The DRM’s results are more stable compared with SPVM.
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 79408-79418
Open AccessA Dimension Reduction Method Used in Detecting Errors of Distribution Transformer Connectivity
Many power utilities may have problems with the quality of data in records about which feeder a distribution transformer is connected to. This affects the operation and maintenance of smart grid infrastructure, outage management, line loss management, and workforce safety. The traditional manual way of verifying and updating the distribution transformer connectivity (DTC) is time-consuming and labor-intensive. Researchers have proposed the method which makes use of secondary side single-phase voltage of distribution transformers to verify DTC. However, when the windings of distribution transformers are yyn0 connected, the performance of the single-phase voltage method (SPVM) is unsatisfactory due to the unbalanced three-phase voltages. This paper proposed a dimension reduction method (DRM) that can convert the unbalanced three-phase voltage to a balanced voltage. The data which include 29 days’ secondary side voltages of 3866 distribution transformers have been collected. The performances of the DRM and the SPVM have been compared. Results show that the DRM always has higher accuracy compared with SPVM. The influences of the maximum voltage difference and the reference distribution transformer have also been discussed. The DRM’s results are more stable compared with SPVM.