Christine Damases Kasi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christine Damases Kasi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Mark F. McEntee
University College Cork
7 shared publications - Claudia Mello-Thoms
University of Iowa
3 shared publications Patrick C. Brennan
Faculty of Health Sciences, Discipline of Medical Radiation Sciences and Brain and Mind Research Institute, M205, Cumberland Campus, The University of Sydney, 75 East St, Room M205, Lidcombe, Sydney, NSW 2141, Australia
2 shared publications- Aaron D. Norman
Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN 55905, USA
1 shared publication - Aimilia Gastounioti
Washington University School of Medicine, Computational Imaging Research Center, Breast Image Computing Lab, St Louis, Missouri, United States
1 shared publication - Carrie Beth Hruska
Department of Radiology, Mayo Clinic, Rochester, USA
1 shared publication
Latest Publications
- 12 May 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 296 (1) , 24-31
Evaluation of LIBRA Software for Fully Automated Mammographic Density Assessment in Breast Cancer Risk Prediction
Automated measures by the Laboratory for Individualized Breast Radiodensity Assessment correlated with established area and volumetric density measures and showed comparable breast cancer associati... Background The associations of density measures from the publicly available Laboratory for Individualized Breast Radiodensity Assessment (LIBRA) software with breast cancer have primarily focused o...
- 12 May 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 296 (1) , 24-31
Evaluation of LIBRA Software for Fully Automated Mammographic Density Assessment in Breast Cancer Risk Prediction
Automated measures by the Laboratory for Individualized Breast Radiodensity Assessment correlated with established area and volumetric density measures and showed comparable breast cancer associati... Background The associations of density measures from the publicly available Laboratory for Individualized Breast Radiodensity Assessment (LIBRA) software with breast cancer have primarily focused o...
- 1 August 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1076) , 20170064
Intercountry analysis of breast density classification using visual grading
Disagreement in mammographic breast density (MBD) assessment can impact breast cancer risk stratification, choices of further breast cancer screening intervals and pathways. This study examines whether inter-country MBD expectations and assessment approaches are associated with differences in MBD assessment. Twenty American Board of Radiology (ABR) examiners and 24 United Kingdom (UK) practitioners using the 4th edition BI-RADS® lexicon assessed 40 mammogram cases of 20 women. Twenty-six Royal Australian and New Zealand College of Radiologists (RANZCR) registered radiologists also assessed the same cases. Inter-observer correlation and agreement were assessed using a Spearman’s correlation (ρ) and weighted Kappa (κw) respectively. Strong positive correlation was observed between the study cohorts on a binary scale (1–2 vs. 3–4) [ABR examiners and RANZCR radiologists (ρ = 0.950); ABR examiners and UK practitioners (ρ = 0.940); RANZCR radiologists and UK practitioners (ρ = 0.958)]. ABR and RANZCR radiologists demonstrated slight agreement [κw = 0.10; 95% CI = -1.13 - 0.43] while ABR and UK practitioners showed a fair agreement [κw = 0.25; 95% CI = -0.42 - 0.61], and an almost perfect agreement was observed between RANZCR radiologists and UK practitioners [κw = 0.95; 95% CI = 0.91 - 0.97]. Findings demonstrate wide international and inter-observer variability in MBD assessment. This level of variability underscores the need for automation and standardisation of MBD assessment. Inter country analysis of mammographic breast density assessment shows variations, with less variation on binary scale than on 4-point scale. With this level of variation automation and standardisation of mammographic breast density assessment becomes more appropriate.
- 1 August 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1076) , 20170064
Intercountry analysis of breast density classification using visual grading
Disagreement in mammographic breast density (MBD) assessment can impact breast cancer risk stratification, choices of further breast cancer screening intervals and pathways. This study examines whether inter-country MBD expectations and assessment approaches are associated with differences in MBD assessment. Twenty American Board of Radiology (ABR) examiners and 24 United Kingdom (UK) practitioners using the 4th edition BI-RADS® lexicon assessed 40 mammogram cases of 20 women. Twenty-six Royal Australian and New Zealand College of Radiologists (RANZCR) registered radiologists also assessed the same cases. Inter-observer correlation and agreement were assessed using a Spearman’s correlation (ρ) and weighted Kappa (κw) respectively. Strong positive correlation was observed between the study cohorts on a binary scale (1–2 vs. 3–4) [ABR examiners and RANZCR radiologists (ρ = 0.950); ABR examiners and UK practitioners (ρ = 0.940); RANZCR radiologists and UK practitioners (ρ = 0.958)]. ABR and RANZCR radiologists demonstrated slight agreement [κw = 0.10; 95% CI = -1.13 - 0.43] while ABR and UK practitioners showed a fair agreement [κw = 0.25; 95% CI = -0.42 - 0.61], and an almost perfect agreement was observed between RANZCR radiologists and UK practitioners [κw = 0.95; 95% CI = 0.91 - 0.97]. Findings demonstrate wide international and inter-observer variability in MBD assessment. This level of variability underscores the need for automation and standardisation of MBD assessment. Inter country analysis of mammographic breast density assessment shows variations, with less variation on binary scale than on 4-point scale. With this level of variation automation and standardisation of mammographic breast density assessment becomes more appropriate.
- 5 April 2016
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 60 (3) , 329-336
Inter‐observer variability in mammographic density assessment using Royal Australian and New Zealand College of Radiologists (RANZCR) synoptic scales
Introduction: The aim of this study was to evaluate observer variability in mammographic density assessment as measured using the Royal Australian and New Zealand College of Radiologists (RANZCR) synoptic scales. Visual assessment of mammographic density by radiologists is commonly used in clinical practice; however, these assessments have been shown to be more subjective than quantitative methods.Methods: The study included 40 cases of left cranial‐caudal (CC) and mediolateral oblique (MLO) radiographs from 20 women.RANZCR‐registered radiologists (n = 26) estimated mammographic breast density of the same images according toRANZCRsynoptic scales 1–4. All images had their volumetric density classified using Volpara Density Grade (VDG) and Average Volumetric Breast Density percentage (AvBD%).Results: The results showed that the radiologists sampled had specialized for 17.18 years (sd12.03) and read 2072 (sd2441) mammograms per year on average. Inter‐observer agreement usingRANZCRsynoptic scales had an average Kappa of 0.360; (95%CI = 0.308–0.412) and a range of 0.078–0.499. Radiologists estimated percentage density was lower by 0.37 thanVDG, with their mean being 2.18 and the meanVDGwas 2.55 (Z = −3.873;P < 0.001).VDGandRANZCRshowed a positive strong correlation (ρ = 0.898;P < 0.001). AvBD% andRANZCRalso showed a positive strong correlation (ρ = 0.904;P < 0.001).Conclusion: The inter‐observer agreement withRANZCRsynoptic scales was fair. Wide inter‐observer variability was observed. Continued research on appropriate assessment methods for mammographic density assessment is required to avoid unnecessary variations.
- 5 April 2016
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 60 (3) , 329-336
Inter‐observer variability in mammographic density assessment using Royal Australian and New Zealand College of Radiologists (RANZCR) synoptic scales
Introduction: The aim of this study was to evaluate observer variability in mammographic density assessment as measured using the Royal Australian and New Zealand College of Radiologists (RANZCR) synoptic scales. Visual assessment of mammographic density by radiologists is commonly used in clinical practice; however, these assessments have been shown to be more subjective than quantitative methods.Methods: The study included 40 cases of left cranial‐caudal (CC) and mediolateral oblique (MLO) radiographs from 20 women.RANZCR‐registered radiologists (n = 26) estimated mammographic breast density of the same images according toRANZCRsynoptic scales 1–4. All images had their volumetric density classified using Volpara Density Grade (VDG) and Average Volumetric Breast Density percentage (AvBD%).Results: The results showed that the radiologists sampled had specialized for 17.18 years (sd12.03) and read 2072 (sd2441) mammograms per year on average. Inter‐observer agreement usingRANZCRsynoptic scales had an average Kappa of 0.360; (95%CI = 0.308–0.412) and a range of 0.078–0.499. Radiologists estimated percentage density was lower by 0.37 thanVDG, with their mean being 2.18 and the meanVDGwas 2.55 (Z = −3.873;P < 0.001).VDGandRANZCRshowed a positive strong correlation (ρ = 0.898;P < 0.001). AvBD% andRANZCRalso showed a positive strong correlation (ρ = 0.904;P < 0.001).Conclusion: The inter‐observer agreement withRANZCRsynoptic scales was fair. Wide inter‐observer variability was observed. Continued research on appropriate assessment methods for mammographic density assessment is required to avoid unnecessary variations.
- 24 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9787, 97871
Inter-observer variability within BI-RADS and RANZCR mammographic density assessment schemes
This study compares variability associated with two visual mammographic density (MD) assessment methods using two separate samples of radiologists. The image test-set comprised of images obtained from 20 women (age 42–89 years). The images were assessed for their MD by twenty American Board of Radiology (ABR) examiners and twenty-six radiologists registered with the Royal Australian and New Zealand College of Radiologists (RANZCR). Images were assessed using the same technology and conditions, however the ABR radiologists used the BI-RADS and the RANZCR radiologists used the RANZCR breast density synoptic. Both scales use a 4-point assessment. The images were then grouped as low- and high-density; low including BIRADS 1 and 2 or RANZCR 1 and 2 and high including BI-RADS 3 and 4 or RANZCR 3 and 4. Four-point BI-RADS and RANZCR showed no or negligible correlation (ρ=-0.029; p<0.859). The average inter-observer agreement on the BI-RADS scale had a Kappa of 0.565; [95% CI = 0.519 – 0.610], and ranged between 0.328–0.669 while the inter-observer agreement using the RANZCR scale had a Kappa of 0.360; [95% CI = 0.308 – 0.412] and a range of 0.078-0.499. Our findings show a wider range of inter-observer variability among RANZCR registered radiologists than the ABR examiners. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 24 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9787, 97871
Inter-observer variability within BI-RADS and RANZCR mammographic density assessment schemes
This study compares variability associated with two visual mammographic density (MD) assessment methods using two separate samples of radiologists. The image test-set comprised of images obtained from 20 women (age 42–89 years). The images were assessed for their MD by twenty American Board of Radiology (ABR) examiners and twenty-six radiologists registered with the Royal Australian and New Zealand College of Radiologists (RANZCR). Images were assessed using the same technology and conditions, however the ABR radiologists used the BI-RADS and the RANZCR radiologists used the RANZCR breast density synoptic. Both scales use a 4-point assessment. The images were then grouped as low- and high-density; low including BIRADS 1 and 2 or RANZCR 1 and 2 and high including BI-RADS 3 and 4 or RANZCR 3 and 4. Four-point BI-RADS and RANZCR showed no or negligible correlation (ρ=-0.029; p<0.859). The average inter-observer agreement on the BI-RADS scale had a Kappa of 0.565; [95% CI = 0.519 – 0.610], and ranged between 0.328–0.669 while the inter-observer agreement using the RANZCR scale had a Kappa of 0.360; [95% CI = 0.308 – 0.412] and a range of 0.078-0.499. Our findings show a wider range of inter-observer variability among RANZCR registered radiologists than the ABR examiners. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 1 January 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (1) , 70-77
Mammographic Breast Density Assessment Using Automated Volumetric Software and Breast Imaging Reporting and Data System (BIRADS) Categorization by Expert Radiologists
- 1 January 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (1) , 70-77
Mammographic Breast Density Assessment Using Automated Volumetric Software and Breast Imaging Reporting and Data System (BIRADS) Categorization by Expert Radiologists
- 17 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9416, 94160A-94160A-8
The impact of mammographic imaging systems on density measurement
- 17 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9416, 94160A-94160A-8
The impact of mammographic imaging systems on density measurement
- Open Access
- 1 January 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 2 (1) , 015501
Mammographic density measurements are not affected by mammography system
Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman’s density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists’ visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer’s equipment affects a woman’s MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation (; ), while the VDG (; ) and AvBD% (; ) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS (; ), however, the systems demonstrated an almost perfect agreement for VDG (; ).- 1 January 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 2 (1) , 015501
Open AccessMammographic density measurements are not affected by mammography system
Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman’s density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists’ visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer’s equipment affects a woman’s MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation (; ), while the VDG (; ) and AvBD% (; ) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS (; ), however, the systems demonstrated an almost perfect agreement for VDG (; ). - 11 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9037, 90370T-90370T-8
Mammographic density measurement: a comparison of automated volumetric density measurement to BIRADS
- 11 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9037, 90370T-90370T-8
Mammographic density measurement: a comparison of automated volumetric density measurement to BIRADS