Xinyao Zhu
Xinyao Zhu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Meng Jin
State Grid Jiangsu Electric Power Maintenance Branch Company Nanjing Jiangsu People's Republic of China
3 shared publicationsJingbo Zhao
State Grid Jiangsu Electric Power Research Institute Nanjing Jiangsu People's Republic of China
2 shared publicationsQian Zhou
State Grid Jiangsu Electric Power Research Institute Nanjing Jiangsu People's Republic of China
2 shared publicationsJiankun Liu
State Grid Jiangsu Electric Power Research Institute Nanjing 211103 Jiangsu People's Republic of China
1 shared publication- Jiankun Liu
Jiangsu Electric Power Company Research Institute, State Grid Corporation of China, Nanjing, 211100, China
1 shared publication Ningyu Zhang
State Grid Jiangsu Electric Power Research Institute Nanjing Jiangsu People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 6 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 798-801
SSO of DFIG‐based wind farm integrated by a hybrid series compensator
Doubly‐fed induction generator (DFIG)‐based wind farms integrated by series compensated transmission lines are confronting with the problem of subsynchronous oscillation (SSO). In this study, the configuration and control stratagem of hybrid series compensator composed of a static synchronous series compensator (SSSC) and a fixed capacitor are proposed, and the SSO of DFIG‐based wind farm integrated by a hybrid series compensator are studied. The results reveal that the SSO risk of the system is lower by using the hybrid series compensator, and the SSO damping is larger with a higher proportion of SSSC in the hybrid series compensator, as well as with a larger compensation impedance or voltage of SSSC. The research is supposed to be helpful for the planning and operating of the power system with large‐scale wind farms integrated.
- 6 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 798-801
Open AccessSSO of DFIG‐based wind farm integrated by a hybrid series compensator
Doubly‐fed induction generator (DFIG)‐based wind farms integrated by series compensated transmission lines are confronting with the problem of subsynchronous oscillation (SSO). In this study, the configuration and control stratagem of hybrid series compensator composed of a static synchronous series compensator (SSSC) and a fixed capacitor are proposed, and the SSO of DFIG‐based wind farm integrated by a hybrid series compensator are studied. The results reveal that the SSO risk of the system is lower by using the hybrid series compensator, and the SSO damping is larger with a higher proportion of SSSC in the hybrid series compensator, as well as with a larger compensation impedance or voltage of SSSC. The research is supposed to be helpful for the planning and operating of the power system with large‐scale wind farms integrated.
- Open Access
- 2 May 2017
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 6 (1) , 181-189
Subsynchronous resonance and its mitigation for power system with unified power flow controller
- 2 May 2017
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 6 (1) , 181-189
Open AccessSubsynchronous resonance and its mitigation for power system with unified power flow controller
- Open Access
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 1323-1326
SSO damping in DFIG‐based wind farms integrated by a hybrid series compensator
With the widespread applications of series compensated capacitors for wind farm integration, some DFIG (doubly fed induction generator) based wind farms are confronting with severe problem of SSO (subsynchronous oscillation). To solve the SSO problem, hybrid series compensators composed of SSSC (static synchronous series compensator) and fixed capacitor are utilised, and a method of supplementary damping control for the converter is proposed in this paper. The position of the converter controller to impose the supplementary damping signal is chosen at first, then supplementary damping control and its principle to damp SSO is presented as well. Finally, time‐domain simulations are performed to analyse and verify the SSO damping effectiveness of the designed supplementary damping control. Meanwhile, the simulation results also suggest that the designed supplementary damping control has no negative effect on the performance of the hybrid series compensator.
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 1323-1326
Open AccessSSO damping in DFIG‐based wind farms integrated by a hybrid series compensator
With the widespread applications of series compensated capacitors for wind farm integration, some DFIG (doubly fed induction generator) based wind farms are confronting with severe problem of SSO (subsynchronous oscillation). To solve the SSO problem, hybrid series compensators composed of SSSC (static synchronous series compensator) and fixed capacitor are utilised, and a method of supplementary damping control for the converter is proposed in this paper. The position of the converter controller to impose the supplementary damping signal is chosen at first, then supplementary damping control and its principle to damp SSO is presented as well. Finally, time‐domain simulations are performed to analyse and verify the SSO damping effectiveness of the designed supplementary damping control. Meanwhile, the simulation results also suggest that the designed supplementary damping control has no negative effect on the performance of the hybrid series compensator.