Taro Kaiju
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Taro Kaiju has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Ashuya Takemoto
1 shared publicationLukas M Bongartz
1 shared publicationMasato Inoue
National Institute of Information and Communications Technology Center for Information and Neural Networks, 1-4, Yamadaoka, Suita, Osaka, 565-0871, JAPAN
1 shared publicationMasayuki Hirata
Department of Neurological Diagnosis and Restoration, Osaka University, 2-2, Yamadaoka, Suita, Osaka, 565-0871, JAPAN
1 shared publicationShuichi Tsuruta
1 shared publicationTakafumi Suzuki
National Institute of Information and Communications Technology Center for Information and Neural Networks, 1-4, Yamadaoka, Suita, Osaka, 565-0871, JAPAN
1 shared publication
Latest Publications
- Open Access
- 17 March 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (3) , 036025
High-density mapping of primate digit representations with a 1152-channel µECoG array
Objective. Advances in brain–machine interfaces (BMIs) are expected to support patients with movement disorders. Electrocorticogram (ECoG) measures electrophysiological activities over a large area using a low-invasive flexible sheet placed on the cortex. ECoG has been considered as a feasible signal source of the clinical BMI device. To capture neural activities more precisely, the feasibility of higher-density arrays has been investigated. However, currently, the number of electrodes is limited to approximately 300 due to wiring difficulties, device size, and system costs. Approach. We developed a high-density recording system with a large coverage (14 × 7 mm2) and using 1152 electrodes by directly integrating dedicated flexible arrays with the neural-recording application-specific integrated circuits and their interposers. Main results. Comparative experiments with a 128-channel array demonstrated that the proposed device could delineate the entire digit representation of a nonhuman primate. Subsampling analysis revealed that higher-amplitude signals can be measured using higher-density arrays. Significance. We expect that the proposed system that simultaneously establishes large-scale sampling, high temporal-precision of electrophysiology, and high spatial resolution comparable to optical imaging will be suitable for next-generation brain-sensing technology.
- 17 March 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (3) , 036025
Open AccessHigh-density mapping of primate digit representations with a 1152-channel µECoG array
Objective. Advances in brain–machine interfaces (BMIs) are expected to support patients with movement disorders. Electrocorticogram (ECoG) measures electrophysiological activities over a large area using a low-invasive flexible sheet placed on the cortex. ECoG has been considered as a feasible signal source of the clinical BMI device. To capture neural activities more precisely, the feasibility of higher-density arrays has been investigated. However, currently, the number of electrodes is limited to approximately 300 due to wiring difficulties, device size, and system costs. Approach. We developed a high-density recording system with a large coverage (14 × 7 mm2) and using 1152 electrodes by directly integrating dedicated flexible arrays with the neural-recording application-specific integrated circuits and their interposers. Main results. Comparative experiments with a 128-channel array demonstrated that the proposed device could delineate the entire digit representation of a nonhuman primate. Subsampling analysis revealed that higher-amplitude signals can be measured using higher-density arrays. Significance. We expect that the proposed system that simultaneously establishes large-scale sampling, high temporal-precision of electrophysiology, and high spatial resolution comparable to optical imaging will be suitable for next-generation brain-sensing technology.
- Open Access
- 27 November 2020
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 5 (4) , 043002
Flexible neural interfaces for brain implants—the pursuit of thinness and high density
- 27 November 2020
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 5 (4) , 043002
Open AccessFlexible neural interfaces for brain implants—the pursuit of thinness and high density