EAEghbal Amidi

Eghbal Amidi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eghbal Amidi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Guang Yang

    Washington Univ. in St. Louis (United States)

    9 shared publications
  • Atahar Mostafa

    Washington Univ. in St. Louis (United States)

    7 shared publications
  • Quing Zhu

    Department of Biomedical Engineering Washington University in St. Louis St. Louis Missouri USA

    7 shared publications
  • Sreyankar Nandy

    Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO 63130, USA

    6 shared publications
  • Quing Zhu

    Washington Univ. in St. Louis (United States)

    4 shared publications
  • Matthew Mutch

    From the Department of Biomedical Engineering (X.L., K.M.S.U., S.K., E.A., G.Y., Q.Z.), Division of Surgery, Barnes-Jewish Hospital (W.C., S.H., M.M.), and Department of Electrical and System Engineering (H.L.), Washington University in St. Louis, 1 Brookings Dr, Mail Box 1097, St Louis, MO 63130; Department of Pathology (D.C.) and Mallinckrodt Institute of Radiology (A.S., Q.Z.), Washington University School of Medicine, St Louis, Mo

    3 shared publications

Latest Publications

  • Fiber endface photoacoustic generator for quantitative photoacoustic tomography

    by Guang Yang, Hengbo Huang, Hongbo Luo, Sitai Kou, Eghbal Amidi, Samuel Achilefu, Quing Zhu

    We demonstrate a novel fiber endface photoacoustic (PA) generator using infrared (IR) 144 laser dye dispersed within an ultraviolet adhesive. The generator provides a wide acoustic bandwidth in the transducer frequency range of 2–7 MHz, high thermal conversion efficiency ( > 90 % ), good PA signal controllability (well-controlled IR 144 concentration), and high feasibility (simple procedures). Through a series of experimental validations, we show that this fiber-based endface PA generator can be a useful tool for a broad range of biomedical applications such as calibrating the local absorption coefficient of biological tissue for quantitative PA tomography.


  • Assessing Rectal Cancer Treatment Response Using Coregistered Endorectal Photoacoustic and US Imaging Paired with Deep Learning

    by Xiandong Leng, K. M. Shihab Uddin, William Chapman, Hongbo Luo, Sitai Kou, Eghbal Amidi, Guang Yang, Deyali Chatterjee, Anup Shetty, Steve Hunt, et al.

    Coregistered endorectal photoacoustic microscopy and US imaging quantified by a neural network demonstrated excellent differentiation between rectal tumor beds with residual cancers and those witho... Background Conventional radiologic modalities perform poorly in the radiated rectum and are often unable to differentiate residual cancer from treatment scarring. Purpose To report the development ...


  • Open Access

    Photoacoustic tomography reconstruction using lag-based delay multiply and sum with a coherence factor improves in vivo ovarian cancer diagnosis

    by Guang Yang, Eghbal Amidi, Quing Zhu

    Ovarian cancer is the fifth most common cause of death due to cancer, and it is the deadliest of all gynecological cancers. Diagnosing ovarian cancer via conventional photoacoustic delay-and-sum beamforming (DAS) presents several challenges, such as poor image resolution and low lesion to background tissue contrast. To address these concerns, we propose an improved beamformer named lag-based delay multiply and sum combined with coherence factor (DMAS-LAG-CF). Simulations and phantom experiments demonstrate that compared with the conventional DAS, the proposed algorithm can provide 1.39 times better resolution and 10.77 dB higher contrast. For patient data, similar performance on contrast ratios has been observed. However, since the diagnostic accuracy between cancer and benign/normal groups is a significant measure, we have extracted photoacoustic histogram features of mean, kurtosis and skewness. DMAS-LAG-CF can improve cancer diagnosis with an AUC of 0.91 for distinguishing malignant vs. benign ovarian lesions when mean and skewness are used as features.


  • Open Access

    Co-registered photoacoustic and ultrasound imaging of human colorectal cancer

    by Guang Yang, Eghbal Amidi, William C. Chapman, Sreyankar Nandy, Atahar Mostafa, Heba Abdelal, Zahra Alipour, Deyali Chatterjee, Matthew Mutch, Quing Zhu

    Photoacoustic imaging (PAI) is an emerging technique that can provide high optical absorption contrast images at reasonable microscale resolution and clinically relevant depths.1 Several studies have established that optical absorption parameters are important biomarkers directly related to the tissue microvasculature, tumor angiogenesis, or tumor hypoxia.2 – 4 In general, PAI is classified into photoacoustic microscopy (PAM) and photoacoustic tomography (PAT).1 Previously, PAM and photoacoustic endoscopy have demonstrated the capability of detecting human colorectal cancer.5,6 However, the low imaging speed (limited by the laser repetition rate and scanning scheme), small imaging area, and moderate penetration depth created obstacles for clinical applications.


  • Classification of human ovarian cancer using functional, spectral, and imaging features obtained from in vivo photoacoustic imaging

    by Eghbal Amidi, Atahar Mostafa, Sreyankar Nandy, Guang Yang, William Middleton, Cary Siegel, Quing Zhu

    We report in this pilot study the diagnostic results of in vivo imaging of patients with ovarian lesions, using a co-registered photoacoustic and ultrasound (PAT/US) system. A total of 39 ovaries from 24 patients were imaged in vivo. PAT functional features, i.e., blood oxygen saturation (sO2) and relative total hemoglobin (rHbT), PAT image features, and PAT spectral features within a region of interest (ROI) in each ovarian tissue were extracted. To select the significant features, a t-test on each feature was performed, and the independent predictors were determined by evaluating correlation between each pair of predictors. To classify the ovarian lesions, we employed a generalized linear model (GLM) and a support vector machine (SVM). We used these classifiers first to distinguish benign/normal lesions from ovaries with invasive epithelial tumors and then to separate normal/benign lesions from all types of ovarian tumors. We developed classifiers once by inclusion of PAT functional features to assess the best diagnostic performance of the classifiers when multiple wavelengths data are available. Second time, we excluded the PAT functional features from the features set to evaluate the best diagnostic performance if only a single wavelength is available. Our results show that using functional features improves the classification performance, especially for distinguishing normal/benign ovarian lesions from all types of tumors. In this case, an area under ROC curve (AUC) of 0.92, 0.93 of testing data was achieved using a GLM and SVM classifier when functional features were included in the feature set while excluding these features resulted in an AUC of 0.89, 0.92, respectively.


  • Low-cost ultrasound and optical gelatin-based phantoms

    by Eghbal Amidi, Guang Yang, K. M. Shihab Uddin, Ryan Wahidi, Quing Zhu

    In this study, a low-cost procedure using evaporated milk is followed to make a gelatin-based phantom with ultrasound and optical properties close to soft tissues. To find out the effect of concentrations of gelatin and evaporated milk on the ultrasound properties, we first made two sets of phantoms. The first set was made by mixing different amounts of gelatin with deionized water (no evaporated milk in this set), while in the second set, evaporated milk concentration was changed (constant gelatin concentration). We measured the ultrasound attenuation of these phantoms at low and high frequency ranges and show that when the gelatin concentration is kept at 5 %, the ultrasound attenuation can vary from 0.4 to 0.6 dB/MHz/cm as the evaporated milk concentration increases from 20 % to 50 %. After getting some idea about the proper concentrations of evaporated milk and gelatin on ultrasound properties, n-propanol alcohol, glass microspheres, and Germall plus preservative were added to our recipe. We then measured the optical properties of the resulted phantom. A diffuse optical tomography system (DOT) was employed for this purpose to measure the optical absorption and reduced scattering coefficients of our phantom at four different wavelengths.


  • Co-registered photoacoustic and ultrasound real-time imaging of colorectal cancer: ex-vivo studies

    by Heba Abdelal, Zahra Alipour, Deyali Chatterjee, Guang Yang, Eghbal Amidi, Sreyankar Nandy, Atahar Mostafa, Quing Zhu, William Chapman Jr, Matthew Mutch

    Colorectal cancer is the second most common malignancy diagnosed globally. Critical need exists for imaging and diagnosis of rectal tumors for both staging and therapeutic response evaluations. We have conducted a pilot study to image and characterize colorectal masses using a real-time co-registered photoacoustic (PAT) and ultrasound (US) system. A total of 8 tissue samples including pre- and post-treatment colorectal cancer, polyps have studied. Four different wavelengths (730, 780, 800, 830 nm) were used to illuminate the sample and a scanning stage was used to scan a large area and obtain a sequence of B-scans. For the pre-treatment colorectal cancer, photoacoustic images have shown significantly higher vascular level than neighbor benign regions of the same sample. The pre-treatment colorectal cancer PAT signal level is also higher than polyps and post-treatment colorectal cancer. Additionally, the quantitative features extracted from PAT and US power spectrum such as spectral slope, mid-band fit and zero MHz intercept have shown statistical significance between pre-treatment colorectal cancer and other 3 categories using t-test. Our initial results have demonstrated that PAT/US has a great potential to reveal tumor angiogenesis development or residual tumors after treatment.


  • Optimizing light delivery through ball-shaped multimode fiber tips in co-registered photoacoustic and ultrasound endo-cavity imaging: simulation and experimental validation

    by Atahar Mostafa, Guang Yang, Eghbal Amidi, Sreyankar Nandy, Quing Zhu

    Adenocarcinoma is a type of cancers that forms in mucus-secreting glands throughout the body. For example, adenocarcinomas make up around 96% of colorectal cancers and some cervical cancers (10%). Depth of invasion for early adenocarcinoma is generally around 1-7 mm. In this report, we propose an optimal design, implementation, and evaluation of an optical fiber-based transvaginal photoacoustic/ultrasound prototype imaging probe for endo-cavity imaging of adenocarcinoma with ball-shaped fiber tips (refractive index = 1.517, radius 0.75 mm), to improve the light illumination homogeneity and increase the light delivery fluence on the central imaging area of the tissue surface. The light delivery system consists of light coupling optics, a custom-made transducer sheath, four 1-mm-core multimode optical fibers with the ball-shaped fiber tip arranged around the transducer. The probe design was optimized by simulating the light fluence distribution of the fibers with and without ball-shaped tips using a 3D model in Zemax for different design parameters such as fiber effective numerical aperture, fiber displacement from the probe base, sheath taper angle, ball-shaped fiber tips’ diameter and refractive index, etc. The laser fluence profiles were experimentally recorded through calibrated intralipid solution by camera at various imaging depths. The output power on the central imaged areas were experimentally measured by calculating the PAT signal strengths from the black threads buried inside chicken breast tissue at various depths and in-vivo photoacoustic imaging of one palmar vein proximal to the human wrist.


  • Evaluation of Ovarian Cancer: Initial Application of Coregistered Photoacoustic Tomography and US

    by Sreyankar Nandy, Atahar Mostafa, Ian S. Hagemann, Matthew A. Powell, Eghbal Amidi, Kathryn Robinson, David G. Mutch, Cary Siegel, Quing Zhu

    Purpose To assess transvaginal coregistered photoacoustic tomography (PAT) and pulse-echo US for diagnosis of ovarian cancer based on functional parameters provided by PAT. Materials and Methods Between February 2017 and December 2017, 26 ovarian masses from 16 participants were successfully imaged in vivo by multispectral photoacoustic imaging, including nine invasive epithelial ovarian cancers (six serous carcinomas and three endometroid adenocarcinomas), three other tumors (two borderline serous tumors and one sex cord-stromal tumor), and 14 benign and normal (hereafter referred to as benign/normal) ovaries. The relative total hemoglobin concentration (rHbT) and mean oxygen saturation (sO2) shown at PAT were used to characterize the ovaries identified at US. Results The average rHbT was 1.9 times higher for invasive epithelial cancers than for the benign/normal ovaries (P = .01). Additionally, the rHbT distribution was extensive in invasive epithelial cancers, but was scattered in benign/normal ovaries. However, the rHbT of two borderline serous tumors and one stromal tumor was in the same range as that of benign/normal ovaries. The mean sO2 of invasive epithelial cancers, and of the borderline and stromal tumors, was 8.2% lower than that of benign/normal ovaries (P = .003). Discussion Invasive epithelial ovarian cancers showed higher and extensive tumor vascularity and lower oxygen saturation than benign and normal ovaries. Two borderline noninvasive serous and one stromal tumor showed low oxygen saturation compared with benign and normal ovaries. ©RSNA, 2018 Online supplemental material is available for this article.