Eghbal Amidi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eghbal Amidi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Guang Yang
Washington Univ. in St. Louis (United States)
9 shared publications Atahar Mostafa
Washington Univ. in St. Louis (United States)
7 shared publications- Quing Zhu
Department of Biomedical Engineering Washington University in St. Louis St. Louis Missouri USA
7 shared publications Sreyankar Nandy
Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO 63130, USA
6 shared publicationsQuing Zhu
Washington Univ. in St. Louis (United States)
4 shared publicationsMatthew Mutch
From the Department of Biomedical Engineering (X.L., K.M.S.U., S.K., E.A., G.Y., Q.Z.), Division of Surgery, Barnes-Jewish Hospital (W.C., S.H., M.M.), and Department of Electrical and System Engineering (H.L.), Washington University in St. Louis, 1 Brookings Dr, Mail Box 1097, St Louis, MO 63130; Department of Pathology (D.C.) and Mallinckrodt Institute of Radiology (A.S., Q.Z.), Washington University School of Medicine, St Louis, Mo
3 shared publications
Latest Publications
- 10 May 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (11) , 2706-2709
Fiber endface photoacoustic generator for quantitative photoacoustic tomography
We demonstrate a novel fiber endface photoacoustic (PA) generator using infrared (IR) 144 laser dye dispersed within an ultraviolet adhesive. The generator provides a wide acoustic bandwidth in the transducer frequency range of 2–7 MHz, high thermal conversion efficiency ( > 90 % ), good PA signal controllability (well-controlled IR 144 concentration), and high feasibility (simple procedures). Through a series of experimental validations, we show that this fiber-based endface PA generator can be a useful tool for a broad range of biomedical applications such as calibrating the local absorption coefficient of biological tissue for quantitative PA tomography.
- 10 May 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (11) , 2706-2709
Fiber endface photoacoustic generator for quantitative photoacoustic tomography
We demonstrate a novel fiber endface photoacoustic (PA) generator using infrared (IR) 144 laser dye dispersed within an ultraviolet adhesive. The generator provides a wide acoustic bandwidth in the transducer frequency range of 2–7 MHz, high thermal conversion efficiency ( > 90 % ), good PA signal controllability (well-controlled IR 144 concentration), and high feasibility (simple procedures). Through a series of experimental validations, we show that this fiber-based endface PA generator can be a useful tool for a broad range of biomedical applications such as calibrating the local absorption coefficient of biological tissue for quantitative PA tomography.
- 23 March 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 299 (2) , 349-358
Assessing Rectal Cancer Treatment Response Using Coregistered Endorectal Photoacoustic and US Imaging Paired with Deep Learning
Coregistered endorectal photoacoustic microscopy and US imaging quantified by a neural network demonstrated excellent differentiation between rectal tumor beds with residual cancers and those witho... Background Conventional radiologic modalities perform poorly in the radiated rectum and are often unable to differentiate residual cancer from treatment scarring. Purpose To report the development ...
- 23 March 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 299 (2) , 349-358
Assessing Rectal Cancer Treatment Response Using Coregistered Endorectal Photoacoustic and US Imaging Paired with Deep Learning
Coregistered endorectal photoacoustic microscopy and US imaging quantified by a neural network demonstrated excellent differentiation between rectal tumor beds with residual cancers and those witho... Background Conventional radiologic modalities perform poorly in the radiated rectum and are often unable to differentiate residual cancer from treatment scarring. Purpose To report the development ...
- Open Access
- 23 March 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (4) , 2250-2263
Photoacoustic tomography reconstruction using lag-based delay multiply and sum with a coherence factor improves in vivo ovarian cancer diagnosis
Ovarian cancer is the fifth most common cause of death due to cancer, and it is the deadliest of all gynecological cancers. Diagnosing ovarian cancer via conventional photoacoustic delay-and-sum beamforming (DAS) presents several challenges, such as poor image resolution and low lesion to background tissue contrast. To address these concerns, we propose an improved beamformer named lag-based delay multiply and sum combined with coherence factor (DMAS-LAG-CF). Simulations and phantom experiments demonstrate that compared with the conventional DAS, the proposed algorithm can provide 1.39 times better resolution and 10.77 dB higher contrast. For patient data, similar performance on contrast ratios has been observed. However, since the diagnostic accuracy between cancer and benign/normal groups is a significant measure, we have extracted photoacoustic histogram features of mean, kurtosis and skewness. DMAS-LAG-CF can improve cancer diagnosis with an AUC of 0.91 for distinguishing malignant vs. benign ovarian lesions when mean and skewness are used as features.
- 23 March 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (4) , 2250-2263
Open AccessPhotoacoustic tomography reconstruction using lag-based delay multiply and sum with a coherence factor improves in vivo ovarian cancer diagnosis
Ovarian cancer is the fifth most common cause of death due to cancer, and it is the deadliest of all gynecological cancers. Diagnosing ovarian cancer via conventional photoacoustic delay-and-sum beamforming (DAS) presents several challenges, such as poor image resolution and low lesion to background tissue contrast. To address these concerns, we propose an improved beamformer named lag-based delay multiply and sum combined with coherence factor (DMAS-LAG-CF). Simulations and phantom experiments demonstrate that compared with the conventional DAS, the proposed algorithm can provide 1.39 times better resolution and 10.77 dB higher contrast. For patient data, similar performance on contrast ratios has been observed. However, since the diagnostic accuracy between cancer and benign/normal groups is a significant measure, we have extracted photoacoustic histogram features of mean, kurtosis and skewness. DMAS-LAG-CF can improve cancer diagnosis with an AUC of 0.91 for distinguishing malignant vs. benign ovarian lesions when mean and skewness are used as features.
- Open Access
- 19 November 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (12) , 121913-13
Co-registered photoacoustic and ultrasound imaging of human colorectal cancer
Photoacoustic imaging (PAI) is an emerging technique that can provide high optical absorption contrast images at reasonable microscale resolution and clinically relevant depths.1 Several studies have established that optical absorption parameters are important biomarkers directly related to the tissue microvasculature, tumor angiogenesis, or tumor hypoxia.2 – 4 In general, PAI is classified into photoacoustic microscopy (PAM) and photoacoustic tomography (PAT).1 Previously, PAM and photoacoustic endoscopy have demonstrated the capability of detecting human colorectal cancer.5,6 However, the low imaging speed (limited by the laser repetition rate and scanning scheme), small imaging area, and moderate penetration depth created obstacles for clinical applications.
- 19 November 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (12) , 121913-13
Open AccessCo-registered photoacoustic and ultrasound imaging of human colorectal cancer
Photoacoustic imaging (PAI) is an emerging technique that can provide high optical absorption contrast images at reasonable microscale resolution and clinically relevant depths.1 Several studies have established that optical absorption parameters are important biomarkers directly related to the tissue microvasculature, tumor angiogenesis, or tumor hypoxia.2 – 4 In general, PAI is classified into photoacoustic microscopy (PAM) and photoacoustic tomography (PAT).1 Previously, PAM and photoacoustic endoscopy have demonstrated the capability of detecting human colorectal cancer.5,6 However, the low imaging speed (limited by the laser repetition rate and scanning scheme), small imaging area, and moderate penetration depth created obstacles for clinical applications.
- 8 April 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (5) , 2303-2317
Classification of human ovarian cancer using functional, spectral, and imaging features obtained from in vivo photoacoustic imaging
We report in this pilot study the diagnostic results of in vivo imaging of patients with ovarian lesions, using a co-registered photoacoustic and ultrasound (PAT/US) system. A total of 39 ovaries from 24 patients were imaged in vivo. PAT functional features, i.e., blood oxygen saturation (sO2) and relative total hemoglobin (rHbT), PAT image features, and PAT spectral features within a region of interest (ROI) in each ovarian tissue were extracted. To select the significant features, a t-test on each feature was performed, and the independent predictors were determined by evaluating correlation between each pair of predictors. To classify the ovarian lesions, we employed a generalized linear model (GLM) and a support vector machine (SVM). We used these classifiers first to distinguish benign/normal lesions from ovaries with invasive epithelial tumors and then to separate normal/benign lesions from all types of ovarian tumors. We developed classifiers once by inclusion of PAT functional features to assess the best diagnostic performance of the classifiers when multiple wavelengths data are available. Second time, we excluded the PAT functional features from the features set to evaluate the best diagnostic performance if only a single wavelength is available. Our results show that using functional features improves the classification performance, especially for distinguishing normal/benign ovarian lesions from all types of tumors. In this case, an area under ROC curve (AUC) of 0.92, 0.93 of testing data was achieved using a GLM and SVM classifier when functional features were included in the feature set while excluding these features resulted in an AUC of 0.89, 0.92, respectively.
- 8 April 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (5) , 2303-2317
Classification of human ovarian cancer using functional, spectral, and imaging features obtained from in vivo photoacoustic imaging
We report in this pilot study the diagnostic results of in vivo imaging of patients with ovarian lesions, using a co-registered photoacoustic and ultrasound (PAT/US) system. A total of 39 ovaries from 24 patients were imaged in vivo. PAT functional features, i.e., blood oxygen saturation (sO2) and relative total hemoglobin (rHbT), PAT image features, and PAT spectral features within a region of interest (ROI) in each ovarian tissue were extracted. To select the significant features, a t-test on each feature was performed, and the independent predictors were determined by evaluating correlation between each pair of predictors. To classify the ovarian lesions, we employed a generalized linear model (GLM) and a support vector machine (SVM). We used these classifiers first to distinguish benign/normal lesions from ovaries with invasive epithelial tumors and then to separate normal/benign lesions from all types of ovarian tumors. We developed classifiers once by inclusion of PAT functional features to assess the best diagnostic performance of the classifiers when multiple wavelengths data are available. Second time, we excluded the PAT functional features from the features set to evaluate the best diagnostic performance if only a single wavelength is available. Our results show that using functional features improves the classification performance, especially for distinguishing normal/benign ovarian lesions from all types of tumors. In this case, an area under ROC curve (AUC) of 0.92, 0.93 of testing data was achieved using a GLM and SVM classifier when functional features were included in the feature set while excluding these features resulted in an AUC of 0.89, 0.92, respectively.
- 6 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10878, 157
Low-cost ultrasound and optical gelatin-based phantoms
In this study, a low-cost procedure using evaporated milk is followed to make a gelatin-based phantom with ultrasound and optical properties close to soft tissues. To find out the effect of concentrations of gelatin and evaporated milk on the ultrasound properties, we first made two sets of phantoms. The first set was made by mixing different amounts of gelatin with deionized water (no evaporated milk in this set), while in the second set, evaporated milk concentration was changed (constant gelatin concentration). We measured the ultrasound attenuation of these phantoms at low and high frequency ranges and show that when the gelatin concentration is kept at 5 %, the ultrasound attenuation can vary from 0.4 to 0.6 dB/MHz/cm as the evaporated milk concentration increases from 20 % to 50 %. After getting some idea about the proper concentrations of evaporated milk and gelatin on ultrasound properties, n-propanol alcohol, glass microspheres, and Germall plus preservative were added to our recipe. We then measured the optical properties of the resulted phantom. A diffuse optical tomography system (DOT) was employed for this purpose to measure the optical absorption and reduced scattering coefficients of our phantom at four different wavelengths.
- 6 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10878, 157
Low-cost ultrasound and optical gelatin-based phantoms
In this study, a low-cost procedure using evaporated milk is followed to make a gelatin-based phantom with ultrasound and optical properties close to soft tissues. To find out the effect of concentrations of gelatin and evaporated milk on the ultrasound properties, we first made two sets of phantoms. The first set was made by mixing different amounts of gelatin with deionized water (no evaporated milk in this set), while in the second set, evaporated milk concentration was changed (constant gelatin concentration). We measured the ultrasound attenuation of these phantoms at low and high frequency ranges and show that when the gelatin concentration is kept at 5 %, the ultrasound attenuation can vary from 0.4 to 0.6 dB/MHz/cm as the evaporated milk concentration increases from 20 % to 50 %. After getting some idea about the proper concentrations of evaporated milk and gelatin on ultrasound properties, n-propanol alcohol, glass microspheres, and Germall plus preservative were added to our recipe. We then measured the optical properties of the resulted phantom. A diffuse optical tomography system (DOT) was employed for this purpose to measure the optical absorption and reduced scattering coefficients of our phantom at four different wavelengths.
- Open Access
- 1 March 2019
- Published by Elsevier in Photoacoustics
- Vol. 13, 66-75
Optimized light delivery probe using ball lenses for co-registered photoacoustic and ultrasound endo-cavity subsurface imaging
- 1 March 2019
- Published by Elsevier in Photoacoustics
- Vol. 13, 66-75
Open AccessOptimized light delivery probe using ball lenses for co-registered photoacoustic and ultrasound endo-cavity subsurface imaging
- 27 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10878, 167
Co-registered photoacoustic and ultrasound real-time imaging of colorectal cancer: ex-vivo studies
Colorectal cancer is the second most common malignancy diagnosed globally. Critical need exists for imaging and diagnosis of rectal tumors for both staging and therapeutic response evaluations. We have conducted a pilot study to image and characterize colorectal masses using a real-time co-registered photoacoustic (PAT) and ultrasound (US) system. A total of 8 tissue samples including pre- and post-treatment colorectal cancer, polyps have studied. Four different wavelengths (730, 780, 800, 830 nm) were used to illuminate the sample and a scanning stage was used to scan a large area and obtain a sequence of B-scans. For the pre-treatment colorectal cancer, photoacoustic images have shown significantly higher vascular level than neighbor benign regions of the same sample. The pre-treatment colorectal cancer PAT signal level is also higher than polyps and post-treatment colorectal cancer. Additionally, the quantitative features extracted from PAT and US power spectrum such as spectral slope, mid-band fit and zero MHz intercept have shown statistical significance between pre-treatment colorectal cancer and other 3 categories using t-test. Our initial results have demonstrated that PAT/US has a great potential to reveal tumor angiogenesis development or residual tumors after treatment.
- 27 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10878, 167
Co-registered photoacoustic and ultrasound real-time imaging of colorectal cancer: ex-vivo studies
Colorectal cancer is the second most common malignancy diagnosed globally. Critical need exists for imaging and diagnosis of rectal tumors for both staging and therapeutic response evaluations. We have conducted a pilot study to image and characterize colorectal masses using a real-time co-registered photoacoustic (PAT) and ultrasound (US) system. A total of 8 tissue samples including pre- and post-treatment colorectal cancer, polyps have studied. Four different wavelengths (730, 780, 800, 830 nm) were used to illuminate the sample and a scanning stage was used to scan a large area and obtain a sequence of B-scans. For the pre-treatment colorectal cancer, photoacoustic images have shown significantly higher vascular level than neighbor benign regions of the same sample. The pre-treatment colorectal cancer PAT signal level is also higher than polyps and post-treatment colorectal cancer. Additionally, the quantitative features extracted from PAT and US power spectrum such as spectral slope, mid-band fit and zero MHz intercept have shown statistical significance between pre-treatment colorectal cancer and other 3 categories using t-test. Our initial results have demonstrated that PAT/US has a great potential to reveal tumor angiogenesis development or residual tumors after treatment.
- 27 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10878, 108785H
Optimizing light delivery through ball-shaped multimode fiber tips in co-registered photoacoustic and ultrasound endo-cavity imaging: simulation and experimental validation
Adenocarcinoma is a type of cancers that forms in mucus-secreting glands throughout the body. For example, adenocarcinomas make up around 96% of colorectal cancers and some cervical cancers (10%). Depth of invasion for early adenocarcinoma is generally around 1-7 mm. In this report, we propose an optimal design, implementation, and evaluation of an optical fiber-based transvaginal photoacoustic/ultrasound prototype imaging probe for endo-cavity imaging of adenocarcinoma with ball-shaped fiber tips (refractive index = 1.517, radius 0.75 mm), to improve the light illumination homogeneity and increase the light delivery fluence on the central imaging area of the tissue surface. The light delivery system consists of light coupling optics, a custom-made transducer sheath, four 1-mm-core multimode optical fibers with the ball-shaped fiber tip arranged around the transducer. The probe design was optimized by simulating the light fluence distribution of the fibers with and without ball-shaped tips using a 3D model in Zemax for different design parameters such as fiber effective numerical aperture, fiber displacement from the probe base, sheath taper angle, ball-shaped fiber tips’ diameter and refractive index, etc. The laser fluence profiles were experimentally recorded through calibrated intralipid solution by camera at various imaging depths. The output power on the central imaged areas were experimentally measured by calculating the PAT signal strengths from the black threads buried inside chicken breast tissue at various depths and in-vivo photoacoustic imaging of one palmar vein proximal to the human wrist.
- 27 February 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10878, 108785H
Optimizing light delivery through ball-shaped multimode fiber tips in co-registered photoacoustic and ultrasound endo-cavity imaging: simulation and experimental validation
Adenocarcinoma is a type of cancers that forms in mucus-secreting glands throughout the body. For example, adenocarcinomas make up around 96% of colorectal cancers and some cervical cancers (10%). Depth of invasion for early adenocarcinoma is generally around 1-7 mm. In this report, we propose an optimal design, implementation, and evaluation of an optical fiber-based transvaginal photoacoustic/ultrasound prototype imaging probe for endo-cavity imaging of adenocarcinoma with ball-shaped fiber tips (refractive index = 1.517, radius 0.75 mm), to improve the light illumination homogeneity and increase the light delivery fluence on the central imaging area of the tissue surface. The light delivery system consists of light coupling optics, a custom-made transducer sheath, four 1-mm-core multimode optical fibers with the ball-shaped fiber tip arranged around the transducer. The probe design was optimized by simulating the light fluence distribution of the fibers with and without ball-shaped tips using a 3D model in Zemax for different design parameters such as fiber effective numerical aperture, fiber displacement from the probe base, sheath taper angle, ball-shaped fiber tips’ diameter and refractive index, etc. The laser fluence profiles were experimentally recorded through calibrated intralipid solution by camera at various imaging depths. The output power on the central imaged areas were experimentally measured by calculating the PAT signal strengths from the black threads buried inside chicken breast tissue at various depths and in-vivo photoacoustic imaging of one palmar vein proximal to the human wrist.
- 1 December 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 289 (3) , 740-747
Evaluation of Ovarian Cancer: Initial Application of Coregistered Photoacoustic Tomography and US
Purpose To assess transvaginal coregistered photoacoustic tomography (PAT) and pulse-echo US for diagnosis of ovarian cancer based on functional parameters provided by PAT. Materials and Methods Between February 2017 and December 2017, 26 ovarian masses from 16 participants were successfully imaged in vivo by multispectral photoacoustic imaging, including nine invasive epithelial ovarian cancers (six serous carcinomas and three endometroid adenocarcinomas), three other tumors (two borderline serous tumors and one sex cord-stromal tumor), and 14 benign and normal (hereafter referred to as benign/normal) ovaries. The relative total hemoglobin concentration (rHbT) and mean oxygen saturation (sO2) shown at PAT were used to characterize the ovaries identified at US. Results The average rHbT was 1.9 times higher for invasive epithelial cancers than for the benign/normal ovaries (P = .01). Additionally, the rHbT distribution was extensive in invasive epithelial cancers, but was scattered in benign/normal ovaries. However, the rHbT of two borderline serous tumors and one stromal tumor was in the same range as that of benign/normal ovaries. The mean sO2 of invasive epithelial cancers, and of the borderline and stromal tumors, was 8.2% lower than that of benign/normal ovaries (P = .003). Discussion Invasive epithelial ovarian cancers showed higher and extensive tumor vascularity and lower oxygen saturation than benign and normal ovaries. Two borderline noninvasive serous and one stromal tumor showed low oxygen saturation compared with benign and normal ovaries. ©RSNA, 2018 Online supplemental material is available for this article.
- 1 December 2018
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 289 (3) , 740-747
Evaluation of Ovarian Cancer: Initial Application of Coregistered Photoacoustic Tomography and US
Purpose To assess transvaginal coregistered photoacoustic tomography (PAT) and pulse-echo US for diagnosis of ovarian cancer based on functional parameters provided by PAT. Materials and Methods Between February 2017 and December 2017, 26 ovarian masses from 16 participants were successfully imaged in vivo by multispectral photoacoustic imaging, including nine invasive epithelial ovarian cancers (six serous carcinomas and three endometroid adenocarcinomas), three other tumors (two borderline serous tumors and one sex cord-stromal tumor), and 14 benign and normal (hereafter referred to as benign/normal) ovaries. The relative total hemoglobin concentration (rHbT) and mean oxygen saturation (sO2) shown at PAT were used to characterize the ovaries identified at US. Results The average rHbT was 1.9 times higher for invasive epithelial cancers than for the benign/normal ovaries (P = .01). Additionally, the rHbT distribution was extensive in invasive epithelial cancers, but was scattered in benign/normal ovaries. However, the rHbT of two borderline serous tumors and one stromal tumor was in the same range as that of benign/normal ovaries. The mean sO2 of invasive epithelial cancers, and of the borderline and stromal tumors, was 8.2% lower than that of benign/normal ovaries (P = .003). Discussion Invasive epithelial ovarian cancers showed higher and extensive tumor vascularity and lower oxygen saturation than benign and normal ovaries. Two borderline noninvasive serous and one stromal tumor showed low oxygen saturation compared with benign and normal ovaries. ©RSNA, 2018 Online supplemental material is available for this article.