JWJim S. Walker

Jim S. Walker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jim S. Walker has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Best Practices for Droplet Dispensing and Sizing in Single-Microdroplet Experiments

    by Jim S. Walker, Sorrel K. Haughton

    Controlled droplet dispensing and accurate droplet sizing are key technical requirements for most experimental approaches to studying individual microdroplets, yet both present significant practical challenges. This tutorial presents best-practice approaches for droplet generation and sizing in single-microdroplet studies, with a particular focus on droplet-on-demand dispensing technologies and in situ optical sizing methods. Under constant conditions, droplet-on-demand dispensers offer controlled, highly reproducible droplet generation across a range of sizes (typically ∼20–80 μm diameter, with <1% variation). We discuss the principles governing dispenser performance and examine the influence of operating parameters, fluid properties, dispenser loading, and jet breakup dynamics on droplet size reproducibility. Particular attention is given to the stochastic nature of droplet formation and the role of satellite droplets, which can introduce substantial uncertainties and complicate precise size control. Complementary droplet sizing methodologies are reviewed, including imaging, phase function-based light-scattering measurements, and cavity-enhanced spectroscopic techniques, highlighting their respective strengths, limitations, and achievable precision. By integrating practical guidance on dispenser operation with a critical assessment of available sizing approaches, this tutorial provides researchers with a framework for improving experimental reproducibility, minimizing artifacts, and achieving accurate droplet size determination in microdroplet investigations.

  • Open Access

    The Role of Aerosol Liquid Water in Droplet-Assisted Ionization Mass Spectrometry

    by Joshua Harrison, Kelvin M. Risby, Barnaby E. A. Miles, Thomas G. Hilditch, Jim S. Walker, Bryan R. Bzdek

    Chemical analysis of aerosols by mass spectrometry is challenging because aerosols contain little mass and have complex compositions. Consequently, relatively few approaches allow online molecular (i.e., minimal fragmentation) analysis on aerosols, particularly for ultrafine (<100 nm) particles. Droplet-assisted ionization (DAI) mass spectrometry is a promising and straightforward approach for aerosol molecular analysis. In DAI, liquid aerosol droplets are delivered directly to the mass spectrometer inlet, where the droplets break up and form molecular ions similar to those observed in electrospray ionization. This study explores how aerosol liquid water, serving as a matrix, controls ion generation in DAI for systems spanning simple binary and more complex ternary ones. The results demonstrate that ion yields are tightly coupled to the aerosol's hygroscopic response, leading to humidity- and phase-dependent ionization efficiencies. When the water to analyte molar ratio is less than ∼2, ion formation is relatively insensitive to water content, but once the matrix to analyte molar ratio exceeds ∼2, ion yield is highly sensitive to aerosol liquid water. These dependencies can be easily minimized by normalizing the environmental relative humidity experienced by the aerosol immediately before delivery to the MS inlet. This study enables a critical evaluation of the factors controlling ionization by this inlet-based approach and identifies experimental designs that will facilitate a more widespread implementation of DAI for aerosol chemical analysis in different application domains. Lastly, this work is an interesting example of how knowledge of aerosol physicochemical properties can answer questions about ionization mechanisms in mass spectrometry.


  • Open Access

    The impact dynamics of picolitre aerosol droplets depositing on surfaces: Effect of wettability, inertia and viscosity

    by Lukesh K. Mahato, Rosie Bracher, Jamie Mclauchlan, Robert L. Harniman, Jim S. Walker


  • Open Access

    Rapid and Sensitive Chemical Analysis of Individual Picolitre Droplets by Mass Spectrometry

    by Jim S. Walker, Bryan R. Bzdek

    Aerosol droplets are unique microcompartments containing microscopic amounts of material and exhibiting surprising chemical reactivity. Although a diverse set of tools exists to characterize the chemical composition of individual submicron particles in air, comparatively fewer approaches can chemically analyze individual, airborne picolitre droplets. We describe a novel approach for mass spectrometric analysis of individual aqueous picolitre droplets (∼2-180 pL volume) containing down to ∼1 pg analyte mass per droplet. Individual droplets are generated using a microdroplet dispenser, imparted a small amount of net charge, and guided to the inlet of a high-resolution mass spectrometer using a linear quadrupole-electrodynamic balance. Analyte molecules within the aqueous droplet are ionized using droplet assisted ionization, where droplet breakup within the mass spectrometer inlet leads to generation of molecular ions. This single droplet mass spectrometry approach is demonstrated for small molecules and proteins. The approach generates clean mass spectra, permits timing of droplet delivery for chemical analysis, and, by avoiding a separate ionization stage, avoids potential artifacts arising from current electrospray-based approaches for picolitre droplet analysis. It is anticipated this approach will permit exploration of the factors governing accelerated chemical reactions in aerosol droplets and will be suitable for sensitive analysis of particularly precious samples in different application domains.


  • Open Access

    High frame-rate imaging of the shape oscillations and spreading dynamics of picolitre droplets impacting on a surface

    by Lauren P. McCarthy, Jonathan P. Reid, Jim S. Walker

    The post-impact dynamics and spreading rates of picolitre liquid droplets on surfaces are critical to many practical and industrial applications, as well as respiratory disease transmission mechanisms. Here we use a high framerate imaging method to explore the shape oscillations and spreading of individual ∼10–180 pl volume droplets (corresponding to ∼30–70 μm in initial droplet diameter) impacting on a surface under ambient conditions with 10 μs temporal resolution. The method allows the surface tension to be accurately extracted from the measured frequency of post-impact shape oscillations for sessile droplets in this size range with surface tensions greater than 40 mN m−1 and viscosities up to at least 3.2 mPa s. The Tanner's law model for predicting sessile droplet spreading rates provides an accurate account of the “steady-state” spreading rate for all droplets with surface tensions in the range 22–73 mN m−1 studied here. However, Tanner's law does not account for the delay in the onset of spreading observed for droplets in this size range, caused by competition between shape oscillations and spreading governing the morphology at short time periods, particularly for surface tensions >22 mN m−1.


  • Open Access

    Accurate Measurements and Simulations of the Evaporation and Trajectories of Individual Solution Droplets

    by Daniel A. Hardy, Joshua F. Robinson, Thomas G. Hilditch, Edward Neal, Pascal Lemaitre, Jim S. Walker, Jonathan P. Reid


  • Open Access

    Dynamics and outcomes of binary collisions of equi-diameter picolitre droplets with identical viscosities

    by Lauren P. McCarthy, Peter Knapp, Jim S. Walker, Justice Archer, Rachael E. H. Miles, Marc E. J. Stettler, Jonathan P. Reid

    Stroboscopic imaging was used to observe the outcomes of binary collisions of picolitre pure water and 40% w/w aqueous sucrose droplets.


  • Open Access

    High time resolution measurements of droplet evaporation kinetics and particle crystallisation

    by D. A. Hardy, J. Archer, P. Lemaitre, R. Vehring, J. P. Reid, J. S. Walker

    High-resolution inflight imaging and measurements of drying droplets enable the evaporation kinetics to be resolved and complex particle crystallisation mechanisms to be observed.


  • Correction to “Accurate Representations of the Microphysical Processes Occurring during the Transport of Exhaled Aerosols and Droplets”

    by Jim S. Walker, Justice Archer, Florence K. A. Gregson, Sarah E. S. Michel, Bryan R. Bzdek, Jonathan P. Reid


  • Accurate Representations of the Microphysical Processes Occurring during the Transport of Exhaled Aerosols and Droplets

    by Jim S. Walker, Justice Archer, Florence K. A. Gregson, Sarah E. S. Michel, Bryan R. Bzdek, Jonathan P. Reid

    Aerosols and droplets from expiratory events play an integral role in transmitting pathogens such as SARS-CoV-2 from an infected individual to a susceptible host. However, there remain significant uncertainties in our understanding of the aerosol droplet microphysics occurring during drying and sedimentation and the effect on the sedimentation outcomes. Here, we apply a new treatment for the microphysical behavior of respiratory fluid droplets to a droplet evaporation/sedimentation model and assess the impact on sedimentation distance, time scale, and particle phase. Above a 100 μm initial diameter, the sedimentation outcome for a respiratory droplet is insensitive to composition and ambient conditions. Below 100 μm, and particularly below 80 μm, the increased settling time allows the exact nature of the evaporation process to play a significant role in influencing the sedimentation outcome. For this size range, an incorrect treatment of the droplet composition, or imprecise use of RH or temperature, can lead to large discrepancies in sedimentation distance (with representative values >1 m, >2 m, and >2 m, respectively). Additionally, a respiratory droplet is likely to undergo a phase change prior to sedimenting if initially <100 μm in diameter, provided that the RH is below the measured phase change RH. Calculations of the potential exposure versus distance from the infected source show that the volume fraction of the initial respiratory droplet distribution, in this size range, which remains elevated above 1 m decreases from 1 at 1 m to 0.125 at 2 m.