Victoria Andino-Pavlovsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Victoria Andino-Pavlovsky has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Kenneth L. Shepard
Columbia University
2 shared publications - Adriaan Johannes Taal
Department of Electrical Engineering, Columbia University, New York, NY 10027, USA
1 shared publication - Alejandro Akrouh
Department of Electrical Engineering, Columbia University, New York, USA
1 shared publication - Elisa Evgenia Konofagou
Department of Biomedical Engineering, Columbia University, New York, USA
1 shared publication - Heyu Yin
Department of Electrical Engineering, Columbia University, New York, USA
1 shared publication - Ilke Uguz
Department of Electrical Engineering, Columbia University, New York, NY 10027, USA
1 shared publication
Latest Publications
- Open Access
Implantable CMOS Deep-Brain Fluorescence Imager with Single-Neuron Resolution
Despite the advantages of optical imaging over electrophysiology, such as cell-type specificity, its application has been limited to the investigation of shallow brain regions (< 2 mm) because of the light scattering property of brain tissue. Passive optical conduits such as graded-index lenses and waveguides have permitted access to deeper locales but with restricted resolution and field of view, while creating massive lesions along the inserted path, with little pathway to improvement in the technology. As an alternative, we present the Acus device, an active implantable complementary metal-oxide-semiconductor (CMOS) neural imager with a 512-pixel silicon image sensor post- processed into a 4.1-mm-long, 120-μm-wide shank with a collinear fiber for illumination, which is able to record transient fluorescent signals in deep brain regions at 400 frames/sec. Acus can achieve single-neuron resolution in functional imaging of GCaMP6s-expressing neurons at a frame rate of 400 frames/sec.
Open AccessImplantable CMOS Deep-Brain Fluorescence Imager with Single-Neuron Resolution
Despite the advantages of optical imaging over electrophysiology, such as cell-type specificity, its application has been limited to the investigation of shallow brain regions (< 2 mm) because of the light scattering property of brain tissue. Passive optical conduits such as graded-index lenses and waveguides have permitted access to deeper locales but with restricted resolution and field of view, while creating massive lesions along the inserted path, with little pathway to improvement in the technology. As an alternative, we present the Acus device, an active implantable complementary metal-oxide-semiconductor (CMOS) neural imager with a 512-pixel silicon image sensor post- processed into a 4.1-mm-long, 120-μm-wide shank with a collinear fiber for illumination, which is able to record transient fluorescent signals in deep brain regions at 400 frames/sec. Acus can achieve single-neuron resolution in functional imaging of GCaMP6s-expressing neurons at a frame rate of 400 frames/sec.
- Top Cited PapersOpen Access
- 7 May 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (19) , eabf6312
Application of a sub–0.1-mm 3 implantable mote for in vivo real-time wireless temperature sensing
This paper presents a sub–0.1-mm 3 , fully integrated, injectable ultrasonic wireless device for biomedical temperature sensing.
- 7 May 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (19) , eabf6312
Top Cited PapersOpen AccessApplication of a sub–0.1-mm 3 implantable mote for in vivo real-time wireless temperature sensing
This paper presents a sub–0.1-mm 3 , fully integrated, injectable ultrasonic wireless device for biomedical temperature sensing.