Luis Antonio Ramírez Torres
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Luis Antonio Ramírez Torres has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Edtson Emilio Herrera-Valencia
Unidad de Investigación en Bioingeniería, Laboratorio de Reología y Fenómenos de Transporte, L-7/Primer Piso; Unidad Multidisciplinaria de Investigación Experimental Zaragoza (UMIEZ), Carrera de Ingeniería Química, Facultad de Estudios Superiores Zaragoza, Universidad Nacional Autónoma de México (UNAM) 1 , Batalla 5 de mayo S/N, Ejército de Oriente, Iztapalapa C.P. 09230, Ciudad de México
5 shared publications - Fausto Calderas
Unidad de Investigación en Bioingeniería, Laboratorio de Reología y Fenómenos de Transporte, L-7/Primer Piso; Unidad Multidisciplinaria de Investigación Experimental Zaragoza (UMIEZ), Carrera de Ingeniería Química, Facultad de Estudios Superiores Zaragoza, Universidad Nacional Autónoma de México (UNAM) 1 , Batalla 5 de mayo S/N, Ejército de Oriente, Iztapalapa C.P. 09230, Ciudad de México
3 shared publications - Vicente Jesús Hernández-Abad
Laboratorio de Investigación Farmacéutica, Facultad de Estudios Superiores Zaragoza, Universidad Nacional Autónoma de México (UNAM) 3 , Batalla 5 de mayo S/N, Ejercito de Oriente, Iztapalapa C. P. 09230, Ciudad de México
3 shared publications - Catalina Soriano-Correa
Unidad de Química Computacional, Facultad de Estudios Superiores (FES)-Zaragoza, Universidad Nacional Autónoma de México (UNAM) 2 , Batalla 5 de mayo S/N, Ejército de Oriente, Iztapalapa C.P. 09230, Ciudad de México
2 shared publications - Diola Marina Nuñez Ramírez
Universidad Juárez del Estado de Durango
2 shared publications F. Calderas
Laboratorio De Reología y Fenómenos De Transporte L‐7/Primer Piso; Unidad Multidisciplinaria De Investigación Experimental Zaragoza (UMIEZ) Carrera De Ingeniería Química Facultad De Estudios Superiores Zaragoza Universidad Nacional Autónoma De México Ciudad de México Mexico
2 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Coupling the rheology of blood samples with low and high cholesterol levels to a one-dimensional cardiovascular formulation
Each heartbeat generates pulse waves that travel through the arterial system; various cardiovascular properties, such as arterial stiffness and blood rheology, determine their shape and the form they propagate. Cardiovascular models are an important tool for studying the cardiovascular system. Most one-dimensional models consider the blood as a Newtonian fluid. Incorporating non-Newtonian effects into them is essential for accurately simulating blood flow, especially under conditions that affect blood rheology, such as elevated cholesterol. To study the effect of elevated cholesterol on pulse waves, we incorporated the experimentally measured storage and loss moduli of blood samples with different cholesterol levels into a one-dimensional cardiovascular formulation. We applied the proposed formulation to single vessel models and to a 116-artery systemic circulation model. A low-frequency analysis provided a mechanistic explanation for the results. We found that blood samples with high cholesterol levels exhibited greater zero-shear-rate viscosity, which, according to the low-frequency analysis, implies a higher vascular resistance and effective vascular compliance, leading to higher blood pressure and lower pulse wave velocity (PWV). Our results showed that high cholesterol levels are associated with higher systolic, diastolic, mean, and pulse pressures, while reducing carotid to femoral pulse wave velocity and decreasing mean and peak blood flow. Our results suggest that the effects of high cholesterol levels are more significant in small arteries. Integrating blood rheology into cardiovascular modeling provides a framework for evaluating various conditions that affect it. It may also enhance the interpretation of pulse wave indices, contributing to the development of noninvasive diagnostic methods.
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Open AccessCoupling the rheology of blood samples with low and high cholesterol levels to a one-dimensional cardiovascular formulation
Each heartbeat generates pulse waves that travel through the arterial system; various cardiovascular properties, such as arterial stiffness and blood rheology, determine their shape and the form they propagate. Cardiovascular models are an important tool for studying the cardiovascular system. Most one-dimensional models consider the blood as a Newtonian fluid. Incorporating non-Newtonian effects into them is essential for accurately simulating blood flow, especially under conditions that affect blood rheology, such as elevated cholesterol. To study the effect of elevated cholesterol on pulse waves, we incorporated the experimentally measured storage and loss moduli of blood samples with different cholesterol levels into a one-dimensional cardiovascular formulation. We applied the proposed formulation to single vessel models and to a 116-artery systemic circulation model. A low-frequency analysis provided a mechanistic explanation for the results. We found that blood samples with high cholesterol levels exhibited greater zero-shear-rate viscosity, which, according to the low-frequency analysis, implies a higher vascular resistance and effective vascular compliance, leading to higher blood pressure and lower pulse wave velocity (PWV). Our results showed that high cholesterol levels are associated with higher systolic, diastolic, mean, and pulse pressures, while reducing carotid to femoral pulse wave velocity and decreasing mean and peak blood flow. Our results suggest that the effects of high cholesterol levels are more significant in small arteries. Integrating blood rheology into cardiovascular modeling provides a framework for evaluating various conditions that affect it. It may also enhance the interpretation of pulse wave indices, contributing to the development of noninvasive diagnostic methods.
- Open Access
- 24 January 2026
- Published by Wiley in Chemical Engineering & Technology
- Vol. 49 (1)
Influence of Blood Rheology on Hemodialysis Efficiency via Computational Simulation
This work presents a computational study of hemodialysis in cocurrent and counter‐current configurations, integrating non‐Newtonian blood rheology at two cholesterol levels using the modified Horner–Armstrong–Wagner–Beris rheological model calibrated with experimental data. The coupled dimensionless momentum and mass transport equations were solved in COMSOL Multiphysics 6.3 to model creatinine diffusion across a semipermeable membrane. A robust computational methodology was developed to implement the rheological model and ensure numerical stability in simulations characterized by strong nonlinearities. Approximately 400 computational simulations were performed to evaluate creatinine removal under varying operating conditions. Results revealed viscosity‐induced performance differences and established optimal dialysate velocities for each flow configuration, contributing a transferable framework for modeling mass transfer processes involving rheological complex fluids.
- 24 January 2026
- Published by Wiley in Chemical Engineering & Technology
- Vol. 49 (1)
Open AccessInfluence of Blood Rheology on Hemodialysis Efficiency via Computational Simulation
This work presents a computational study of hemodialysis in cocurrent and counter‐current configurations, integrating non‐Newtonian blood rheology at two cholesterol levels using the modified Horner–Armstrong–Wagner–Beris rheological model calibrated with experimental data. The coupled dimensionless momentum and mass transport equations were solved in COMSOL Multiphysics 6.3 to model creatinine diffusion across a semipermeable membrane. A robust computational methodology was developed to implement the rheological model and ensure numerical stability in simulations characterized by strong nonlinearities. Approximately 400 computational simulations were performed to evaluate creatinine removal under varying operating conditions. Results revealed viscosity‐induced performance differences and established optimal dialysate velocities for each flow configuration, contributing a transferable framework for modeling mass transfer processes involving rheological complex fluids.
- Open Access
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Continuous flow of a thixotropic elasto-viscoplastic-banded structured fluid: Exponential structure rheological constitutive equation
In this work, the viscoelastic behavior of a complex structured liquid in a continuous squeeze flow is analyzed. This flow is simulated allowing a continuous flow of liquid into the narrow gap between two circular plates though the lower plate. The complex liquid is characterized by the exponential structure rheological (ESR) constitutive equation, which is a generalized exponential thixotropic-elasto-viscoplastic-banded model, chosen for this study due to its capacity to predict non-Newtonian and complex behavior such as (i) shear-thinning, (ii) shear-thickening, (iii) yield stress, (iv) thixotropy, (iv) rheopexy, and (v) shear banding flow behavior. The exponential rheological equation of state is defined by a class of exponential Phan-Thien–Tanner-type models, which includes specific cases documented in the literature. The viscoelastic, kinetic, and structural mechanisms in the ESR model are characterized by the association of non-dimensional numbers to each mechanism. To solve the set of non-linear partial differential equations, a perturbation scheme is suggested, based on a small parameter that represents the ratio between two characteristic lengths. At zeroth order (neglecting the inertial mechanisms of the momentum equation), it is found that the normal force on the upper disk is directly related to shear dependent viscosity (thixotropy, shear-thinning, shear-thickening, yield stress behavior, and concentration effects). At first order, the normal force is related to the effects of the elasticity, and it is parallel to the first normal stress difference associated with the elasticity of the ESR structured fluid.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Open AccessContinuous flow of a thixotropic elasto-viscoplastic-banded structured fluid: Exponential structure rheological constitutive equation
In this work, the viscoelastic behavior of a complex structured liquid in a continuous squeeze flow is analyzed. This flow is simulated allowing a continuous flow of liquid into the narrow gap between two circular plates though the lower plate. The complex liquid is characterized by the exponential structure rheological (ESR) constitutive equation, which is a generalized exponential thixotropic-elasto-viscoplastic-banded model, chosen for this study due to its capacity to predict non-Newtonian and complex behavior such as (i) shear-thinning, (ii) shear-thickening, (iii) yield stress, (iv) thixotropy, (iv) rheopexy, and (v) shear banding flow behavior. The exponential rheological equation of state is defined by a class of exponential Phan-Thien–Tanner-type models, which includes specific cases documented in the literature. The viscoelastic, kinetic, and structural mechanisms in the ESR model are characterized by the association of non-dimensional numbers to each mechanism. To solve the set of non-linear partial differential equations, a perturbation scheme is suggested, based on a small parameter that represents the ratio between two characteristic lengths. At zeroth order (neglecting the inertial mechanisms of the momentum equation), it is found that the normal force on the upper disk is directly related to shear dependent viscosity (thixotropy, shear-thinning, shear-thickening, yield stress behavior, and concentration effects). At first order, the normal force is related to the effects of the elasticity, and it is parallel to the first normal stress difference associated with the elasticity of the ESR structured fluid.
- Open Access
- 1 March 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (3)
Non-linear electro-rheological model of a membrane immersed in Tanner-Power law fluids applied to outer hair cells: Shear-thinning mechanisms
Flexoelectric actuation employs an applied electric field to induce membrane curvature, which is the mechanism utilized by the outer hair cells (OHC) present in the inner ear. The model developed for this study, representing the OHC, integrates two key components: (i) an approximation of the flexoelectric membrane shape equation for circular membranes attached to the inner surface of a circular capillary, and (ii) the coupled capillary flow of contacting liquid viscoelastic phases characterized by the Tanner-Power law rheological equation of state. A second-order non-linear differential equation for average curvature has been derived, and a robust numerical method has been programmed. This model simplifies to a linear model used previously. The main challenge involves identifying and describing the enhancement in curvature change rate. It was observed that low symmetry, low viscosity, and soft membrane and shear-thickening behavior of the phases enhance the curvature change rate. Additionally, there exists a critical electric field frequency value that maximizes the curvature change rate (resonance effect). The current theory, model, and computational simulations add to the ongoing development comprehension of how biological membrane shape actuation through electromechanical couplings.
- 1 March 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (3)
Open AccessNon-linear electro-rheological model of a membrane immersed in Tanner-Power law fluids applied to outer hair cells: Shear-thinning mechanisms
Flexoelectric actuation employs an applied electric field to induce membrane curvature, which is the mechanism utilized by the outer hair cells (OHC) present in the inner ear. The model developed for this study, representing the OHC, integrates two key components: (i) an approximation of the flexoelectric membrane shape equation for circular membranes attached to the inner surface of a circular capillary, and (ii) the coupled capillary flow of contacting liquid viscoelastic phases characterized by the Tanner-Power law rheological equation of state. A second-order non-linear differential equation for average curvature has been derived, and a robust numerical method has been programmed. This model simplifies to a linear model used previously. The main challenge involves identifying and describing the enhancement in curvature change rate. It was observed that low symmetry, low viscosity, and soft membrane and shear-thickening behavior of the phases enhance the curvature change rate. Additionally, there exists a critical electric field frequency value that maximizes the curvature change rate (resonance effect). The current theory, model, and computational simulations add to the ongoing development comprehension of how biological membrane shape actuation through electromechanical couplings.
- Open Access
- 15 February 2024
- Published by Universidad Nacional Autonoma de Mexico
- No. 40,p. 154-161
Estudio del comportamiento reológico de pulpas de mineral con diferentes tamaños de partícula y su efecto en la hidrodinámica de un biorreactor con agitación continua (CSTR) en un proceso de biolixiviación
El presente trabajo contribuye a la comprensión del proceso de biolixiviación para la purificación de concentrados de hierro en función de su respuesta reológica, y por medio de un análisis hidrodinámico computacional, a la mejora de las condiciones de flujo en un biorreactor de agitación continua (CSTR). Específicamente, se estudió la respuesta reológica de dos tamaños de partícula en las pulpas de mineral (Dp = 44 μm y 72 μm). La respuesta reológica de las pulpas de mineral a flujo cortante simple estacionario (FS) y a flujo oscilatorio de pequeña amplitud de deformación (SAOS) mostraron que, a un menor tamaño de partícula, aumentó su respuesta reológica y, por ende, disminuyó el tiempo del proceso de biolixiviación en un biorreactor. El espectro mecánico al flujo de las pulpas de minerales con menor tamaño de partícula presentó una fuerza de gel de S = 0.0468 Pa∙s con un exponente de nr = 0.802 a tiempos de relajación cortos. Por otro lado, el estudio hidrodinámico del biorreactor realizado a través de la Dinámica de Fluidos Computacionales (CFD), empleando el software comercial COMSOL Multiphysics 6.1, mostró que, a partir de una velocidad de agitación (N) de 200 rpm en el biorreactor, las líneas de corriente presentaron la misma forma. Además, estas no se ven alteradas por la respuesta reológica. La comparación de las líneas de corriente y las curvas de flujo adimensionales (Np vs Re) en las distintas configuraciones duales de impulsores (Rushton-Maxflo), sugiere que la mejor configuración de impulsores fue la Rushton (arriba) - Maxflo (abajo), ya que estas generan un ahorro energético de ≈ 9 % en comparación con las demás configuraciones. Finalmente, al analizar los mapas de viscosidad a las diferentes velocidades de agitación en el biorreactor, se observó que a una velocidad de agitación de 400 rpm se obtienen las mejores condiciones de mezclado, es decir, una mejor homogeneidad de las pulpas de mineral en todo el biorreactor (CSTR), evitando su sedimentación y favoreciendo el proceso de biolixiviación.
- 15 February 2024
- Published by Universidad Nacional Autonoma de Mexico
- No. 40,p. 154-161
Open AccessEstudio del comportamiento reológico de pulpas de mineral con diferentes tamaños de partícula y su efecto en la hidrodinámica de un biorreactor con agitación continua (CSTR) en un proceso de biolixiviación
El presente trabajo contribuye a la comprensión del proceso de biolixiviación para la purificación de concentrados de hierro en función de su respuesta reológica, y por medio de un análisis hidrodinámico computacional, a la mejora de las condiciones de flujo en un biorreactor de agitación continua (CSTR). Específicamente, se estudió la respuesta reológica de dos tamaños de partícula en las pulpas de mineral (Dp = 44 μm y 72 μm). La respuesta reológica de las pulpas de mineral a flujo cortante simple estacionario (FS) y a flujo oscilatorio de pequeña amplitud de deformación (SAOS) mostraron que, a un menor tamaño de partícula, aumentó su respuesta reológica y, por ende, disminuyó el tiempo del proceso de biolixiviación en un biorreactor. El espectro mecánico al flujo de las pulpas de minerales con menor tamaño de partícula presentó una fuerza de gel de S = 0.0468 Pa∙s con un exponente de nr = 0.802 a tiempos de relajación cortos. Por otro lado, el estudio hidrodinámico del biorreactor realizado a través de la Dinámica de Fluidos Computacionales (CFD), empleando el software comercial COMSOL Multiphysics 6.1, mostró que, a partir de una velocidad de agitación (N) de 200 rpm en el biorreactor, las líneas de corriente presentaron la misma forma. Además, estas no se ven alteradas por la respuesta reológica. La comparación de las líneas de corriente y las curvas de flujo adimensionales (Np vs Re) en las distintas configuraciones duales de impulsores (Rushton-Maxflo), sugiere que la mejor configuración de impulsores fue la Rushton (arriba) - Maxflo (abajo), ya que estas generan un ahorro energético de ≈ 9 % en comparación con las demás configuraciones. Finalmente, al analizar los mapas de viscosidad a las diferentes velocidades de agitación en el biorreactor, se observó que a una velocidad de agitación de 400 rpm se obtienen las mejores condiciones de mezclado, es decir, una mejor homogeneidad de las pulpas de mineral en todo el biorreactor (CSTR), evitando su sedimentación y favoreciendo el proceso de biolixiviación.
- 1 April 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (4) , 041907
Hemorheological and biochemical study in patients with liver cirrhosis
In this study, rheological techniques are used to measure the flow properties of blood from 52 patients with liver cirrhosis. A comparative analysis included a control group (23 persons) to determine the stage of the disease in cirrhotic patients. An important correlation relating the blood biochemical composition with the rheological response was found. Two rheological techniques were employed: simple shear-flow and small amplitude oscillatory shear. The “whole blood viscosity” (WBV) exhibits non-Newtonian shear-thinning behavior. Cirrhotic patients show low WBV levels as well as low values of viscoelastic response compared to those of the control group. Viscosity curves in decompensated cirrhotic patients tend toward a Newtonian behavior (constant viscosity) at high shear rates. Regarding the complex viscosity, there are clear differences between compensated and decompensated patients. The viscoelastic response reveals a change in the slope of the elastic modulus (G′) with frequency as compared to the response of the control group. In general, blood elasticity was observed to decrease as the disease progresses (i.e., blood tends to become less elastic, becoming a Newtonian fluid in advanced cirrhotic patients). These results represent a promising alternative to evaluate the incidence of cirrhosis in patients using fast, inexpensive, and noninvasive tests to confirm liver cirrhosis diseases.
- 1 April 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (4) , 041907
Hemorheological and biochemical study in patients with liver cirrhosis
In this study, rheological techniques are used to measure the flow properties of blood from 52 patients with liver cirrhosis. A comparative analysis included a control group (23 persons) to determine the stage of the disease in cirrhotic patients. An important correlation relating the blood biochemical composition with the rheological response was found. Two rheological techniques were employed: simple shear-flow and small amplitude oscillatory shear. The “whole blood viscosity” (WBV) exhibits non-Newtonian shear-thinning behavior. Cirrhotic patients show low WBV levels as well as low values of viscoelastic response compared to those of the control group. Viscosity curves in decompensated cirrhotic patients tend toward a Newtonian behavior (constant viscosity) at high shear rates. Regarding the complex viscosity, there are clear differences between compensated and decompensated patients. The viscoelastic response reveals a change in the slope of the elastic modulus (G′) with frequency as compared to the response of the control group. In general, blood elasticity was observed to decrease as the disease progresses (i.e., blood tends to become less elastic, becoming a Newtonian fluid in advanced cirrhotic patients). These results represent a promising alternative to evaluate the incidence of cirrhosis in patients using fast, inexpensive, and noninvasive tests to confirm liver cirrhosis diseases.
- 1 December 2019
- Published by Elsevier in Minerals Engineering
- Vol. 144
A rheological study of the bioleaching process of an iron ore for the elimination of gangue minerals
- 1 December 2019
- Published by Elsevier in Minerals Engineering
- Vol. 144
A rheological study of the bioleaching process of an iron ore for the elimination of gangue minerals