Jia Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jia Li has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Kailu Zhang
School of Medical Engineering, Department of Cardiology of The First Affiliated Hospital of Xinxiang Medical University, Xinxiang Medical University, Xinxiang, China
3 shared publications- Tianyu Zhang
ENT Institute, Department of Facial Plastic and Reconstructive Surgery, Eye & ENT Hospital, Fudan University, Shanghai 200031, China
3 shared publications Xueling Zhang
School of Medical Engineering, Department of Cardiology of The First Affiliated Hospital of Xinxiang Medical University, Xinxiang Medical University, Xinxiang, China
3 shared publicationsZiya Zhao
School of Medical Engineering, Department of Cardiology of The First Affiliated Hospital of Xinxiang Medical University, Xinxiang Medical University, Xinxiang, China
3 shared publications- Fei Lin
The First Affiliated Hospital of Xinxiang Medical College, Xinxiang, Henan, China
2 shared publications Wu Ren
School of Medical Engineering, Department of Cardiology of The First Affiliated Hospital of Xinxiang Medical University, Xinxiang Medical University, Xinxiang, China
2 shared publications
Latest Publications
- 4 January 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- p. 1-12
Modeling and analysis of explicit dynamics of foot landing
The research aims to investigate the mechanical response of footfalls at different velocities to understand the mechanism of heel injury and provide a scientific basis for the prevention and treatment of heel fractures. A three-dimensional solid model of foot drop was constructed using anatomical structures segmented from medical CT scans, including bone, cartilage, ligaments, plantar fascia, and soft tissues, and the impact velocities of the foot were set to be 2 m/s, 4 m/s, 6 m/s, 8 m/s, and 10 m/s. Explicit kinetic analysis methods were used to investigate the mechanical response of the foot landing with different speeds to explore the damage mechanism of heel bone at different impact velocities. Lower impact velocities result in relatively low stress on the medial cortex and posterior talar articular bony surfaces, which may result in minor injury or stress adaptation in the heel. As the impact velocity increases, the stresses on the medial cortex and posterior taller articular surface also increase significantly, greatly raising the risk of heel fractures. This study holds significant implications for safeguarding foot health and enhancing the safety of athletes and individuals engaged in high-impact sports. Graphical Abstract
- 4 January 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- p. 1-12
Modeling and analysis of explicit dynamics of foot landing
The research aims to investigate the mechanical response of footfalls at different velocities to understand the mechanism of heel injury and provide a scientific basis for the prevention and treatment of heel fractures. A three-dimensional solid model of foot drop was constructed using anatomical structures segmented from medical CT scans, including bone, cartilage, ligaments, plantar fascia, and soft tissues, and the impact velocities of the foot were set to be 2 m/s, 4 m/s, 6 m/s, 8 m/s, and 10 m/s. Explicit kinetic analysis methods were used to investigate the mechanical response of the foot landing with different speeds to explore the damage mechanism of heel bone at different impact velocities. Lower impact velocities result in relatively low stress on the medial cortex and posterior talar articular bony surfaces, which may result in minor injury or stress adaptation in the heel. As the impact velocity increases, the stresses on the medial cortex and posterior taller articular surface also increase significantly, greatly raising the risk of heel fractures. This study holds significant implications for safeguarding foot health and enhancing the safety of athletes and individuals engaged in high-impact sports. Graphical Abstract
- Open Access
- 5 March 2024
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 19 (1) , 1-13
Biomechanical characteristics of Sanders type II and III calcaneal fractures fixed by open reduction and internal fixation and percutaneous minimally invasive fixation
Background: This work investigated the differences in the biomechanical properties of open reduction and internal fixation (ORIF) and percutaneous minimally invasive fixation (PMIF) for the fixation of calcaneal fractures (Sanders type II and III calcaneal fractures as examples) through finite element analysis. Methods: Based on CT images of the human foot and ankle, according to the principle of three-point fixation, namely the sustentaculum tali, the anterior process and the calcaneal tuberosity were fixed. Three-dimensional finite element models of Sanders type II and III calcaneal fractures fixed by ORIF and PMIF were established. The proximal surfaces of the tibia, fibula and soft tissue were constrained, and ground reaction force and Achilles tendon force loads were added to simulate balanced standing. Results: The maximum stress was 80.54, 211.59 and 113.88 MPa for the calcaneus, screws and plates in the ORIF group and 70.02 and 209.46 MPa for the calcaneus and screws in the PMIF group, respectively; the maximum displacement was 0.26, 0.21 and 0.12 mm for the calcaneus, screws and plates in the ORIF group and 0.20 and 0.14 mm for the calcaneus and screws in the PMIF group, respectively. The values obtained from the simulation were within the permissible stress and elastic deformation range of the materials used in the model, and there was no significant stress concentration. The maximum stress and displacement of the calcaneus and implants were slightly lower in the PMIF group than in the ORIF group when fixing Sanders type II and III calcaneal fractures. Conclusions: This study may provide a reference for optimising the design of implants, the development of individualised preoperative plans and the choice of clinical surgical approach.
- 5 March 2024
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 19 (1) , 1-13
Open AccessBiomechanical characteristics of Sanders type II and III calcaneal fractures fixed by open reduction and internal fixation and percutaneous minimally invasive fixation
Background: This work investigated the differences in the biomechanical properties of open reduction and internal fixation (ORIF) and percutaneous minimally invasive fixation (PMIF) for the fixation of calcaneal fractures (Sanders type II and III calcaneal fractures as examples) through finite element analysis. Methods: Based on CT images of the human foot and ankle, according to the principle of three-point fixation, namely the sustentaculum tali, the anterior process and the calcaneal tuberosity were fixed. Three-dimensional finite element models of Sanders type II and III calcaneal fractures fixed by ORIF and PMIF were established. The proximal surfaces of the tibia, fibula and soft tissue were constrained, and ground reaction force and Achilles tendon force loads were added to simulate balanced standing. Results: The maximum stress was 80.54, 211.59 and 113.88 MPa for the calcaneus, screws and plates in the ORIF group and 70.02 and 209.46 MPa for the calcaneus and screws in the PMIF group, respectively; the maximum displacement was 0.26, 0.21 and 0.12 mm for the calcaneus, screws and plates in the ORIF group and 0.20 and 0.14 mm for the calcaneus and screws in the PMIF group, respectively. The values obtained from the simulation were within the permissible stress and elastic deformation range of the materials used in the model, and there was no significant stress concentration. The maximum stress and displacement of the calcaneus and implants were slightly lower in the PMIF group than in the ORIF group when fixing Sanders type II and III calcaneal fractures. Conclusions: This study may provide a reference for optimising the design of implants, the development of individualised preoperative plans and the choice of clinical surgical approach.
- Open Access
- 14 October 2022
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2022, 1-10
Multi-Flexible Body Dynamics Modeling and Experimental Study of the Patient Rehabilitation Transfer Device
Objectives. The patient rehabilitation transfer device is a typical personnel transfer equipment, which is mainly composed of outriggers, support arm, lifting arms, hooks, handrails, hydraulic cylinders, and other components. The existing research on the device is mainly focused on the configuration design and transfer mode, and the research on its dynamic characteristics during the transfer process has not been thoroughly discussed. Methodology. Based on the existing research, a portable hydraulic rehabilitation patient transfer device has been developed. Then the multi-rigid body dynamic and finite element flexible body models were established. Next, the dynamic characteristic difference between the two models of the device was studied. Results. As shown in the results, the finite element multi-flexible body model has obvious flexible vibration in the lifting stage, and the amplitude reaches 16mm in the motion startup stage due to the influence of rigid-flexible coupling. The tip acceleration of the flexible body model was also influenced by the vibration, and the maximum acceleration value reaches 0.06m/s2. According to the test results, the maximum acceleration of the terminal reaches 0.05m/s2, which is close to the finite-element multi-flexible model simulation results. The experimentally measured natural frequency of the device is 3.1Hz, which is also close to 3.2Hz calculated by the simulation. Because the flexible component in the flexible model is only the lift arm, the natural frequency is slightly larger than the experimental value. Conclusion. According to the stress value of the finite element multi-body model motion process, the maximum stress appears at the moment when the motion reaches the top end, and the instantaneous stress reaches 206Mpa, which is in line with the allowable stress range of the material design. The data obtained in this study will provide help for the follow-up clinical rehabilitation and intelligent device research.
- 14 October 2022
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2022, 1-10
Open AccessMulti-Flexible Body Dynamics Modeling and Experimental Study of the Patient Rehabilitation Transfer Device
Objectives. The patient rehabilitation transfer device is a typical personnel transfer equipment, which is mainly composed of outriggers, support arm, lifting arms, hooks, handrails, hydraulic cylinders, and other components. The existing research on the device is mainly focused on the configuration design and transfer mode, and the research on its dynamic characteristics during the transfer process has not been thoroughly discussed. Methodology. Based on the existing research, a portable hydraulic rehabilitation patient transfer device has been developed. Then the multi-rigid body dynamic and finite element flexible body models were established. Next, the dynamic characteristic difference between the two models of the device was studied. Results. As shown in the results, the finite element multi-flexible body model has obvious flexible vibration in the lifting stage, and the amplitude reaches 16mm in the motion startup stage due to the influence of rigid-flexible coupling. The tip acceleration of the flexible body model was also influenced by the vibration, and the maximum acceleration value reaches 0.06m/s2. According to the test results, the maximum acceleration of the terminal reaches 0.05m/s2, which is close to the finite-element multi-flexible model simulation results. The experimentally measured natural frequency of the device is 3.1Hz, which is also close to 3.2Hz calculated by the simulation. Because the flexible component in the flexible model is only the lift arm, the natural frequency is slightly larger than the experimental value. Conclusion. According to the stress value of the finite element multi-body model motion process, the maximum stress appears at the moment when the motion reaches the top end, and the instantaneous stress reaches 206Mpa, which is in line with the allowable stress range of the material design. The data obtained in this study will provide help for the follow-up clinical rehabilitation and intelligent device research.
- 1 October 2020
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 137, 110233
Measurement method for external auditory canal and clinical application in congenital aural stenosis
- 1 October 2020
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 137, 110233
Measurement method for external auditory canal and clinical application in congenital aural stenosis
- Open Access
- 1 June 2020
- Published by Wiley in Shock and Vibration
- Vol. 2020, 1-17
Experimental and Numerical Studies on Vibration Modes and Transcranial Attenuation Characteristics in Unilateral Bone Conduction Hearing
Bone conduction (BC) hearing devices have been used to improve hearing in patients with unilateral conductive hearing loss; however, the clinical results of improvement in the sound localization ability are still controversial. Transcranial transmission in BC may be an important factor affecting sound localization abilities. Transcranial or interaural attenuation, derived from energy attenuation during the BC process, is determined by the different transfer functions of multiple pathways and affected by the whole-head vibration modes. The purpose of this study is to analyze the frequency dependence of BC vibration modes of the whole head, the contribution of middle and inner ear pathways to BC hearing, and the relationship between transcranial attenuation results by dynamics measurement and hearing thresholds. Experimental studies of vibration modes and transcranial attenuation characteristics in BC are performed using scanning laser Doppler vibrometry (LDV) measurements on human cadaver heads. Differences in vibration modes between the excitation and contralateral sides are observed. Additionally, a multiscale human whole-head FE model, including the skull, bony outer ear, ossicular chains, and bony inner ear structures, is proposed to study the mechanism of BC in the human hearing system. After verifying the rationality of the FE model using mechanical impedance and frequency response data, the transcranial attenuation on the temporal bone surfaces and the middle ear structure is calculated in the FE model. Moreover, the vibration characteristics of bilateral ossicular chains and the cochlear bony wall are observed in the whole-head FM model to study their contributions to BC hearing. By analyzing the experimental and numerical results of the vibration modes and the frequency response of the whole head incorporating the ossicular chain and cochlear bony wall, the intrinsic relationship between the results of transcranial attenuation by 1D LDV, 3D LDV, and hearing threshold measurements is further investigated.
- 1 June 2020
- Published by Wiley in Shock and Vibration
- Vol. 2020, 1-17
Open AccessExperimental and Numerical Studies on Vibration Modes and Transcranial Attenuation Characteristics in Unilateral Bone Conduction Hearing
Bone conduction (BC) hearing devices have been used to improve hearing in patients with unilateral conductive hearing loss; however, the clinical results of improvement in the sound localization ability are still controversial. Transcranial transmission in BC may be an important factor affecting sound localization abilities. Transcranial or interaural attenuation, derived from energy attenuation during the BC process, is determined by the different transfer functions of multiple pathways and affected by the whole-head vibration modes. The purpose of this study is to analyze the frequency dependence of BC vibration modes of the whole head, the contribution of middle and inner ear pathways to BC hearing, and the relationship between transcranial attenuation results by dynamics measurement and hearing thresholds. Experimental studies of vibration modes and transcranial attenuation characteristics in BC are performed using scanning laser Doppler vibrometry (LDV) measurements on human cadaver heads. Differences in vibration modes between the excitation and contralateral sides are observed. Additionally, a multiscale human whole-head FE model, including the skull, bony outer ear, ossicular chains, and bony inner ear structures, is proposed to study the mechanism of BC in the human hearing system. After verifying the rationality of the FE model using mechanical impedance and frequency response data, the transcranial attenuation on the temporal bone surfaces and the middle ear structure is calculated in the FE model. Moreover, the vibration characteristics of bilateral ossicular chains and the cochlear bony wall are observed in the whole-head FM model to study their contributions to BC hearing. By analyzing the experimental and numerical results of the vibration modes and the frequency response of the whole head incorporating the ossicular chain and cochlear bony wall, the intrinsic relationship between the results of transcranial attenuation by 1D LDV, 3D LDV, and hearing threshold measurements is further investigated.
- 1 September 2017
- Published by Elsevier in Hearing Research
- Vol. 353, 97-103
A comparative study of MED-EL FMT attachment to the long process of the incus in intact middle ears and its attachment to disarticulated stapes head
- 1 September 2017
- Published by Elsevier in Hearing Research
- Vol. 353, 97-103
A comparative study of MED-EL FMT attachment to the long process of the incus in intact middle ears and its attachment to disarticulated stapes head