MJMinshan Jiang

Minshan Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Minshan Jiang has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Feng Li

    School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, China

    5 shared publications
  • Xuedian Zhang

    Shanghai Key Laboratory of Contemporary Optics System, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, People’s Republic of China

    5 shared publications
  • Hua Chen

    School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China

    3 shared publications
  • Xiang Xu

    Shanghai Key Laboratory of Contemporary Optics System, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, People’s Republic of China

    3 shared publications
  • Xue-Dian Zhang

    Shanghai Key Laboratory of Contemporary Optics System, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China

    3 shared publications
  • Zhizheng Wu

    Department of Precision Mechanical Engineering, Shanghai University, Shanghai, China

    3 shared publications

Latest Publications

  • LCNet: lightweight segmentation network for blood vessel segmentation in retinal imaging

    by Minshan Jiang, Cuicui Xie, Shuai Huang, Yukun Zhang, Jihui Mao, Xuedian Zhang, Xiang Xu

    Precise retinal vessel segmentation techniques are crucial for computer-aided clinical diagnosis. Recent advancements in deep learning have considerably enhanced segmentation accuracy (ACC); however, existing methods often struggle with thin and fuzzy boundaries due to cross-connection redundancy. Most mainstream models rely on complex encoders, resulting in high parameter counts and resource demands. Therefore, we propose LCNet, a lightweight U-shaped network with depth-separable convolution to minimize parameters and computational costs. It incorporates a synergistic coordinate attention module to enhance feature learning and captures multiscale features through the atrous spatial pyramid pooling module. Additionally, it introduces four side-output layers for extra supervision. Evaluating LCNet on four classical datasets (DRIVE, STARE, CHASEDB1, and IOSTAR), LCNet achieves global accuracies of 96.02%, 97.95%, 97.95%, and 97.77%. Our experiments that LCNet delivers enhanced performance with only 2.65 M parameters and 21.2 GFLOPs on DRIVE. We also demonstrate the effectiveness of LCNet on fundus images with lesions and optical coherence tomography angiography images, establishing it as a lightweight model with high efficiency and ACC for retinal vessel segmentation.

  • Open Access

    Research and Practice of full English Teaching of Applied Optics in Chinese University

    by Minshan Jiang, Shuai Huang

    Applied Optics is one of the compulsory professional courses for the Optoelectronic Information major. In the period of internationalization, the goal of modern higher education is to cultivate high-level compound talents with independent research ability and global competitiveness. Proficiency and comprehensive use of English have become the core qualities of high-level talents for Chinese undergraduate students to participate in international cooperations. Internationalization also puts forward higher requirements for cultivation, emphasizing the deep integration of cross-cultural communication skills and professional knowledge. This paper analyzes the appropriate mode of full English teaching in applied optics, and points out some key problems in the full English teaching practice in Chinese universities. This paper introduces the experience and understanding of the full English teaching in applied optics from several aspects, hoping to be helpful for the full English teaching of science and engineering in non-native English-speaking countries.

  • CCS-UNet: a cross-channel spatial attention model for accurate retinal vessel segmentation

    by Yong-Fei Zhu, Xiang Xu, Xue-Dian Zhang, Min-Shan Jiang

    Precise segmentation of retinal vessels plays an important role in computer-assisted diagnosis. Deep learning models have been applied to retinal vessel segmentation, but the efficacy is limited by the significant scale variation of vascular structures and the intricate background of retinal images. This paper supposes a cross-channel spatial attention U-Net (CCS-UNet) for accurate retinal vessel segmentation. In comparison to other models based on U-Net, our model employes a ResNeSt block for the encoder-decoder architecture. The block has a multi-branch structure that enables the model to extract more diverse vascular features. It facilitates weight distribution across channels through the incorporation of soft attention, which effectively aggregates contextual information in vascular images. Furthermore, we suppose an attention mechanism within the skip connection. This mechanism serves to enhance feature integration across various layers, thereby mitigating the degradation of effective information. It helps acquire cross-channel information and enhance the localization of regions of interest, ultimately leading to improved recognition of vascular structures. In addition, the feature fusion module (FFM) module is used to provide semantic information for a more refined vascular segmentation map. We evaluated CCS-UNet based on five benchmark retinal image datasets, DRIVE, CHASEDB1, STARE, IOSTAR and HRF. Our proposed method exhibits superior segmentation efficacy compared to other state-of-the-art techniques with a global accuracy of 0.9617/0.9806/0.9766/0.9786/0.9834 and AUC of 0.9863/0.9894/0.9938/0.9902/0.9855 on DRIVE, CHASEDB1, STARE, IOSTAR and HRF respectively. Ablation studies are also performed to evaluate the the relative contributions of different architectural components. Our proposed model is potential for diagnostic aid of retinal diseases.


  • Open Access

    A Novel High-Efficiency Password Authentication and Key Agreement Protocol for Mobile Client-Server

    by Xiang Xu, Yu Wang, Xue-Dian Zhang, Min-Shan Jiang

    With the development of wireless technology, people increasingly rely on mobile devices. Since most mobile devices transmit sensitive information via insecure public channels, it is important to design multiauthentication key agreement protocols for security protection. Traditional scholars tend to use traditional public-key cryptosystems (PKCs) in their protocols to improve security. High-cost operations (e.g., elliptic curve point multiplication and bilinear pairing) were widely used in their scheme but were not suitable for mobile devices because of limited computing resources. In this study, we designed a novel high-efficiency multiauthentication and key agreement protocol and demonstrate its security in the random oracle model. Compared with other protocols, our proposed scheme only uses string concatenation operations, one-way hash functions, and XOR operations. In addition, our protocol requires much fewer computing resources to achieve the same level of security.


  • Open Access

    A Fast Generative Adversarial Network for High-Fidelity Optical Coherence Tomography Image Synthesis

    by Nan Ge, Yixi Liu, Xiang Xu, Xuedian Zhang, Minshan Jiang

    (1) Background: We present a fast generative adversarial network (GAN) for generating high-fidelity optical coherence tomography (OCT) images. (2) Methods: We propose a novel Fourier-FastGAN (FOF-GAN) to produce OCT images. To improve the image quality of the synthetic images, a new discriminator with a Fourier attention block (FAB) and a new generator with fast Fourier transform (FFT) processes were redesigned. (3) Results: We synthesized normal, diabetic macular edema (DME), and drusen images from the Kermany dataset. When training with 2800 images with 50,000 epochs, our model used only 5 h on a single RTX 2080Ti GPU. Our synthetic images are realistic to recognize the retinal layers and pathological features. The synthetic images were evaluated by a VGG16 classifier and the Fréchet inception distance (FID). The reliability of our model was also demonstrated in the few-shot learning with only 100 pictures. (4) Conclusions: Using a small computing budget and limited training data, our model exhibited good performance for generating OCT images with a 512 × 512 resolution in a few hours. Fast retinal OCT image synthesis is an aid for data augmentation medical applications of deep learning.


  • Open Access

    Improved Complementary Pulmonary Nodule Segmentation Model Based on Multi-Feature Fusion

    by Tiequn Tang, Feng Li, Minshan Jiang, Xunpeng Xia, Rongfu Zhang, Kailin Lin

    Accurate segmentation of lung nodules from pulmonary computed tomography (CT) slices plays a vital role in the analysis and diagnosis of lung cancer. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance in the automatic segmentation of lung nodules. However, they are still challenged by the large diversity of segmentation targets, and the small inter-class variances between the nodule and its surrounding tissues. To tackle this issue, we propose a features complementary network according to the process of clinical diagnosis, which made full use of the complementarity and facilitation among lung nodule location information, global coarse area, and edge information. Specifically, we first consider the importance of global features of nodules in segmentation and propose a cross-scale weighted high-level feature decoder module. Then, we develop a low-level feature decoder module for edge feature refinement. Finally, we construct a complementary module to make information complement and promote each other. Furthermore, we weight pixels located at the nodule edge on the loss function and add an edge supervision to the deep supervision, both of which emphasize the importance of edges in segmentation. The experimental results demonstrate that our model achieves robust pulmonary nodule segmentation and more accurate edge segmentation.


  • Joint optic disk and cup segmentation for glaucoma screening using a region-based deep learning network

    by Feng Li, Wenjie Xiang, Lijuan Zhang, Wenzhe Pan, Xuedian Zhang, Minshan Jiang, Haidong Zou

    Objectives To develop and validate an end-to-end region-based deep convolutional neural network (R-DCNN) to jointly segment the optic disc (OD) and optic cup (OC) in retinal fundus images for precise cup-to-disc ratio (CDR) measurement and glaucoma screening. Methods In total, 2440 retinal fundus images were retrospectively obtained from 2033 participants. An R-DCNN was presented for joint OD and OC segmentation, where the OD and OC segmentation problems were formulated into object detection problems. We compared R-DCNN’s segmentation performance on our in-house dataset with that of four ophthalmologists while performing quantitative, qualitative and generalization analyses on the publicly available both DRISHIT-GS and RIM-ONE v3 datasets. The Dice similarity coefficient (DC), Jaccard coefficient (JC), overlapping error (E), sensitivity (SE), specificity (SP) and area under the curve (AUC) were measured. Results On our in-house dataset, the proposed model achieved a 98.51% DC and a 97.07% JC for OD segmentation, and a 97.63% DC and a 95.39% JC for OC segmentation, achieving a performance level comparable to that of the ophthalmologists. On the DRISHTI-GS dataset, our approach achieved 97.23% and 94.17% results in DC and JC results for OD segmentation, respectively, while it achieved a 94.56% DC and an 89.92% JC for OC segmentation. Additionally, on the RIM-ONE v3 dataset, our model generated DC and JC values of 96.89% and 91.32% on the OD segmentation task, respectively, whereas the DC and JC values acquired for OC segmentation were 88.94% and 78.21%, respectively. Conclusion The proposed approach achieved very encouraging performance on the OD and OC segmentation tasks, as well as in glaucoma screening. It has the potential to serve as a useful tool for computer-assisted glaucoma screening.


  • Top Cited Papers

    Deep learning-based automated detection for diabetic retinopathy and diabetic macular oedema in retinal fundus photographs

    by Feng Li, Yuguang Wang, Tianyi Xu, Lin Dong, Lei Yan, Minshan Jiang, Xuedian Zhang, Hong Jiang, Zhizheng Wu, Haidong Zou

    Objectives To present and validate a deep ensemble algorithm to detect diabetic retinopathy (DR) and diabetic macular oedema (DMO) using retinal fundus images. Methods A total of 8739 retinal fundus images were collected from a retrospective cohort of 3285 patients. For detecting DR and DMO, a multiple improved Inception-v4 ensembling approach was developed. We measured the algorithm’s performance and made a comparison with that of human experts on our primary dataset, while its generalization was assessed on the publicly available Messidor-2 dataset. Also, we investigated systematically the impact of the size and number of input images used in training on model’s performance, respectively. Further, the time budget of training/inference versus model performance was analyzed. Results On our primary test dataset, the model achieved an 0.992 (95% CI, 0.989–0.995) AUC corresponding to 0.925 (95% CI, 0.916-0.936) sensitivity and 0.961 (95% CI, 0.950–0.972) specificity for referable DR, while the sensitivity and specificity for ophthalmologists ranged from 0.845 to 0.936, and from 0.912 to 0.971, respectively. For referable DMO, our model generated an AUC of 0.994 (95% CI, 0.992–0.996) with a 0.930 (95% CI, 0.919–0.941) sensitivity and 0.971 (95% CI, 0.965–0.978) specificity, whereas ophthalmologists obtained sensitivities ranging between 0.852 and 0.946, and specificities ranging between 0.926 and 0.985. Conclusion This study showed that the deep ensemble model exhibited excellent performance in detecting DR and DMO, and had good robustness and generalization, which could potentially help support and expand DR/DMO screening programs.


  • Lesion-aware convolutional neural network for chest radiograph classification

    by F. Li, J.-X. Shi, L. Yan, Y.-G. Wang, X.-D. Zhang, M.-S. Jiang, Z.-Z. Wu, K.-Q. Zhou