Franklin G. Miller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Franklin G. Miller has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- A. A. Sztuc
University College London
4 shared publications A. Alton
Augustana University, Sioux Falls, SD 57197
4 shared publicationsA. Ashkenazi
Tel Aviv University, Tel Aviv-Yafo
4 shared publicationsA. Basharina-Freshville
University College London, London, WC1E 6BT
4 shared publications- A. Bashyal
Brookhaven National Laboratory, Upton, NY 11973
4 shared publications A. Betancur Rodríguez
Universidad EIA, Envigado, Antioquia
4 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08018
Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08018
Open AccessCharge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
- Open Access
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Measurement of exclusive π + -argon interactions using ProtoDUNE-SP
We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Open AccessMeasurement of exclusive π + -argon interactions using ProtoDUNE-SP
We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.
- 23 December 2025
- Published by Elsevier in Cryogenics
- Vol. 154
A gravity independent hydrogen heat pipe
- 23 December 2025
- Published by Elsevier in Cryogenics
- Vol. 154
A gravity independent hydrogen heat pipe
- Open Access
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Supernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Open AccessSupernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- Open Access
- 14 November 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (9)
First measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV / c beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV / c setting and 379 ± 35 mbarns for the 7 GeV / c setting. Published by the American Physical Society 2024
- 14 November 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (9)
Open AccessFirst measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV / c beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV / c setting and 379 ± 35 mbarns for the 7 GeV / c setting. Published by the American Physical Society 2024
- 6 October 2023
- Published by Springer Nature
- p. 472-478
Results of a Nitrogen Pulsating Heat Pipe with Subsections in a Series Configuration
- 6 October 2023
- Published by Springer Nature
- p. 472-478
Results of a Nitrogen Pulsating Heat Pipe with Subsections in a Series Configuration
- 1 May 2023
- Published by American Society of Clinical Oncology (ASCO) in JCO Oncology Practice
- Vol. 19 (5) , 225-229
Ethical Outreach for Rural Cancer Care in the United States: Balancing Access With Optimal Clinical Outcomes
- 1 May 2023
- Published by American Society of Clinical Oncology (ASCO) in JCO Oncology Practice
- Vol. 19 (5) , 225-229
Ethical Outreach for Rural Cancer Care in the United States: Balancing Access With Optimal Clinical Outcomes
- 1 February 2022
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 172
Numerical study of the thermal performance of a hydrogen pulsating heat pipe
- 1 February 2022
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 172
Numerical study of the thermal performance of a hydrogen pulsating heat pipe
- 1 January 2020
- Published by Project MUSE in Perspectives in Biology and Medicine
- Vol. 63 (2) , 219
Introduction to the Special Issue on the Belmont Report
- 1 January 2020
- Published by Project MUSE in Perspectives in Biology and Medicine
- Vol. 63 (2) , 219
Introduction to the Special Issue on the Belmont Report
- 21 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Superconducting Current Leads Under Pulsed Current Conditions
Cryogenic superconducting devices such as a SMES device can require current leads that must operate under conditions where the current is delivered in pulses. The focus of this study was to observe the electrical and thermal behavior of conduction-cooled superconducting current leads in hopes to develop a better under-standing of normal zone propagation when pulsed currents are ap-plied for future design purposes. Leads made of copper tubing sol-dered in parallel to 2G HTS tape were made to allow the normal zone propagation to be observed. The leads were evacuated and connected to a power source at one end and the cold finger of a cry-ocooler at the other end. The test fixture allowed for a distribution of temperature and voltage measurements to be made. Pulsed DC current was supplied to allow the observation of lead response as a function of current level for different ramp cycles. A transient 1-D numerical model was also developed to calculate the current lead temperature in space and time. The lead dimensions used in the model match those used in the experiment. Results of the experi-ment validate the numerical model and are used to develop a better understanding of the thermal and electrical properties of supercon-ducting current leads under pulsed conditions.
- 21 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Superconducting Current Leads Under Pulsed Current Conditions
Cryogenic superconducting devices such as a SMES device can require current leads that must operate under conditions where the current is delivered in pulses. The focus of this study was to observe the electrical and thermal behavior of conduction-cooled superconducting current leads in hopes to develop a better under-standing of normal zone propagation when pulsed currents are ap-plied for future design purposes. Leads made of copper tubing sol-dered in parallel to 2G HTS tape were made to allow the normal zone propagation to be observed. The leads were evacuated and connected to a power source at one end and the cold finger of a cry-ocooler at the other end. The test fixture allowed for a distribution of temperature and voltage measurements to be made. Pulsed DC current was supplied to allow the observation of lead response as a function of current level for different ramp cycles. A transient 1-D numerical model was also developed to calculate the current lead temperature in space and time. The lead dimensions used in the model match those used in the experiment. Results of the experi-ment validate the numerical model and are used to develop a better understanding of the thermal and electrical properties of supercon-ducting current leads under pulsed conditions.