Manuel Melo Bicchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Manuel Melo Bicchi has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Aditi Narechania
Jesse Brown VA Medical Center Chicago Illinois USA
1 shared publication - Alan R. Towne
Department of Neurology, Virginia Commonwealth University, Richmond
1 shared publication - Alexandra Roach
Malcom Randall VA Medical Center Gainesville Florida USA
1 shared publication - Andrea Hildebrand
Portland VA Medical Center Portland Oregon USA
1 shared publication - Anthony Mefford
San Francisco VA Medical Center San Francisco California USA
1 shared publication - Ayham Alkhachroum
University of Miami
1 shared publication
Latest Publications
- Open Access
Validation of drug‐resistant epilepsy identification algorithms in US Veterans across diverse care settings
Objective: Early recognition of drug‐resistant epilepsy (DRE) is critical for timely referral to comprehensive epilepsy centers (CECs). Our prior pilot study in the Veterans Health Administration (VHA) demonstrated the feasibility of an algorithm‐based approach to identify DRE within selected CECs. In this study, we validated and refined these algorithms in a broader, national cohort, including CEC and non‐CEC care, to optimize algorithms for different care settings. Methods: We conducted a multicenter, retrospective study of randomly sampled veterans with epilepsy on ≥2 antiseizure medications (ASMs) from 1999 to 2024. Chart review by 26 epilepsy providers rated DRE status. Ninety‐six candidate algorithms using combinations of six criteria—number of ASMs, treatment duration, dose thresholds, pregabalin exclusion, intractable International Classification of Diseases (ICD) codes, and electroencephalography (EEG)/magnetic resonance imaging (MRI) utilization—were evaluated. Performance for DRE classification was evaluated among all veterans, and separately for CEC or non‐CEC care. Results: Among 970 veterans on ≥2 lifetime ASMs, 518 (53.4%) were rated as DRE, 363 (37.4%) as non‐DRE, and 89 (9.2%) as undetermined. Veterans with DRE were younger (mean age = 68.9 vs. 72.0 years) and more frequently had at least one intractable ICD code (46.1% vs. 18.2%), EEG (77.8% vs. 66.7%), or MRI (78.0% vs. 65.8%) compared with non‐DRE (all p ‐values <.001). Among all veterans, the best overall algorithm (area under the curve [AUC] = .701) identified DRE as either (1) exposure to 3+ ASMs or (2) exposure to two ASMs for at least 1 year, with the requirement of past EEG/MRI and intractable ICD code documentation. This algorithm was also highly effective among veterans who received CEC (AUC = .756) or only non‐CEC care (AUC = .678). Significance: This national validation study confirms that medication‐based algorithms can identify DRE within VHA administrative data across care settings (CECs and non‐CECs). This supports the implementation of a standardized DRE definition for quality improvement, surveillance, and referral optimization within the VHA.
Open AccessValidation of drug‐resistant epilepsy identification algorithms in US Veterans across diverse care settings
Objective: Early recognition of drug‐resistant epilepsy (DRE) is critical for timely referral to comprehensive epilepsy centers (CECs). Our prior pilot study in the Veterans Health Administration (VHA) demonstrated the feasibility of an algorithm‐based approach to identify DRE within selected CECs. In this study, we validated and refined these algorithms in a broader, national cohort, including CEC and non‐CEC care, to optimize algorithms for different care settings. Methods: We conducted a multicenter, retrospective study of randomly sampled veterans with epilepsy on ≥2 antiseizure medications (ASMs) from 1999 to 2024. Chart review by 26 epilepsy providers rated DRE status. Ninety‐six candidate algorithms using combinations of six criteria—number of ASMs, treatment duration, dose thresholds, pregabalin exclusion, intractable International Classification of Diseases (ICD) codes, and electroencephalography (EEG)/magnetic resonance imaging (MRI) utilization—were evaluated. Performance for DRE classification was evaluated among all veterans, and separately for CEC or non‐CEC care. Results: Among 970 veterans on ≥2 lifetime ASMs, 518 (53.4%) were rated as DRE, 363 (37.4%) as non‐DRE, and 89 (9.2%) as undetermined. Veterans with DRE were younger (mean age = 68.9 vs. 72.0 years) and more frequently had at least one intractable ICD code (46.1% vs. 18.2%), EEG (77.8% vs. 66.7%), or MRI (78.0% vs. 65.8%) compared with non‐DRE (all p ‐values <.001). Among all veterans, the best overall algorithm (area under the curve [AUC] = .701) identified DRE as either (1) exposure to 3+ ASMs or (2) exposure to two ASMs for at least 1 year, with the requirement of past EEG/MRI and intractable ICD code documentation. This algorithm was also highly effective among veterans who received CEC (AUC = .756) or only non‐CEC care (AUC = .678). Significance: This national validation study confirms that medication‐based algorithms can identify DRE within VHA administrative data across care settings (CECs and non‐CECs). This supports the implementation of a standardized DRE definition for quality improvement, surveillance, and referral optimization within the VHA.
- 8 April 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056015
Deep learning for robust detection of interictal epileptiform discharges
Objective. Automatic detection of interictal epileptiform discharges (IEDs, short as ‘spikes’) from an epileptic brain can help predict seizure recurrence and support the diagnosis of epilepsy. Developing fast, reliable and robust detection methods for IEDs based on scalp or intracranial electroencephalogram (iEEG) may facilitate online seizure monitoring and closed-loop neurostimulation. Approach. We developed a new deep learning approach, which employs a long short-term memory network architecture (‘IEDnet’) and an auxiliary classifier generative adversarial network (AC-GAN), to train on both expert-annotated and augmented spike events from iEEG recordings of epilepsy patients. We validated our IEDnet with two real-world iEEG datasets, and compared IEDnet with the support vector machine (SVM) and random forest (RF) classifiers on their detection performances. Main results. IEDnet achieved excellent cross-validated detection performances in terms of both sensitivity and specificity, and outperformed SVM and RF. Synthetic spike samples augmented by AC-GAN further improved the detection performance. In addition, the performance of IEDnet was robust with respect to the sampling frequency and noise. Furthermore, we demonstrated the cross-institutional generalization ability of IEDnet while testing between two datasets. Significance. IEDnet achieves excellent detection performances in identifying interictal spikes. AC-GAN can produce augmented iEEG samples to improve supervised deep learning.
- 8 April 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056015
Deep learning for robust detection of interictal epileptiform discharges
Objective. Automatic detection of interictal epileptiform discharges (IEDs, short as ‘spikes’) from an epileptic brain can help predict seizure recurrence and support the diagnosis of epilepsy. Developing fast, reliable and robust detection methods for IEDs based on scalp or intracranial electroencephalogram (iEEG) may facilitate online seizure monitoring and closed-loop neurostimulation. Approach. We developed a new deep learning approach, which employs a long short-term memory network architecture (‘IEDnet’) and an auxiliary classifier generative adversarial network (AC-GAN), to train on both expert-annotated and augmented spike events from iEEG recordings of epilepsy patients. We validated our IEDnet with two real-world iEEG datasets, and compared IEDnet with the support vector machine (SVM) and random forest (RF) classifiers on their detection performances. Main results. IEDnet achieved excellent cross-validated detection performances in terms of both sensitivity and specificity, and outperformed SVM and RF. Synthetic spike samples augmented by AC-GAN further improved the detection performance. In addition, the performance of IEDnet was robust with respect to the sampling frequency and noise. Furthermore, we demonstrated the cross-institutional generalization ability of IEDnet while testing between two datasets. Significance. IEDnet achieves excellent detection performances in identifying interictal spikes. AC-GAN can produce augmented iEEG samples to improve supervised deep learning.