Connor H. Ligeikis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Connor H. Ligeikis has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey T. Scruggs
Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA
3 shared publications Jeff Scruggs
University of Michigan,Department of Civil and Environmental Engineering,Ann Arbor,MI,USA,48108
2 shared publications- Bozidar Stojadinovic
ETH Zurich
1 shared publication - Giuseppe Abbiati
Aarhus University
1 shared publication Richard Christenson
Professor, Dept. of Civil and Environmental Engineering, Univ. of Connecticut, 261 Glenbrook Rd., Storrs, CT 06269
1 shared publicationStefano Marelli
Senior Scientist, Chair of Risk, Safety and Uncertainty Quantification, Dept. of Civil, Environmental and Geomatic Engineering, Institute of Structural Engineering, 5, Stefano-Franscini Platz, Zurich 8093, Switzerland
1 shared publication
Latest Publications
- 26 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 32 (5) , 1770-1784
Multiobjective Vector Control of a Three-Phase Vibratory Energy Harvester
In vibration energy-harvesting technologies, feedback control is required to maximize the average power generated from stochastic disturbances. In large-scale applications, it is often advantageous to use three-phase conversion technologies for transduction. In such situations, vector control techniques can be used to optimally control the transducer currents in the direct-quadrature reference frame, as dynamic functions of feedback measurements. In this paradigm, converted energy is optimally controlled via the quadrature current. The direct current is only used to maintain control of the quadrature current when the machine’s internal back electromotive force (EMF) exceeds the voltage of the power bus, a technique called field weakening. Due to increased dissipation in the stator coil, the use of field weakening results in a reduction in power conversion, relative to what would theoretically be possible with a larger bus voltage. This overvoltage issue can be alternatively addressed by imposing a competing objective in the optimization of the quadrature current controller such that the frequency and duration of these overvoltage events are reduced. However, this also results in reduced generated power, due to the need to satisfy the competing constraint. This article examines the tradeoff between these two approaches to overvoltage compensation and illustrates a methodology for determining the optimum balance between the two approaches.
- 26 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 32 (5) , 1770-1784
Multiobjective Vector Control of a Three-Phase Vibratory Energy Harvester
In vibration energy-harvesting technologies, feedback control is required to maximize the average power generated from stochastic disturbances. In large-scale applications, it is often advantageous to use three-phase conversion technologies for transduction. In such situations, vector control techniques can be used to optimally control the transducer currents in the direct-quadrature reference frame, as dynamic functions of feedback measurements. In this paradigm, converted energy is optimally controlled via the quadrature current. The direct current is only used to maintain control of the quadrature current when the machine’s internal back electromotive force (EMF) exceeds the voltage of the power bus, a technique called field weakening. Due to increased dissipation in the stator coil, the use of field weakening results in a reduction in power conversion, relative to what would theoretically be possible with a larger bus voltage. This overvoltage issue can be alternatively addressed by imposing a competing objective in the optimization of the quadrature current controller such that the frequency and duration of these overvoltage events are reduced. However, this also results in reduced generated power, due to the need to satisfy the competing constraint. This article examines the tradeoff between these two approaches to overvoltage compensation and illustrates a methodology for determining the optimum balance between the two approaches.
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 2541-2548
Risk-Sensitive Control of Vibratory Energy Harvesters
Linear-quadratic-Gaussian (LQG) optimal control theory can be used to maximize the average electrical power generated by a vibratory energy harvester subjected to random disturbances. However, feedback controllers designed using the LQG framework often require large peak power flows for their successful implementation, which may be undesirable for several reasons. In this paper, we propose using a risk-sensitive performance measure to synthesize control laws for stochastic vibratory energy harvesters. The proposed methodology is applied in two examples, in which we show how the risk-sensitive parameter can be systematically tuned to maximize power generation and mitigate excessive power flows. The first example involves a simple single-degree-of-freedom oscillator subjected to a bandpass filtered noise excitation, and the second pertains to ocean wave energy harvesting.
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 2541-2548
Risk-Sensitive Control of Vibratory Energy Harvesters
Linear-quadratic-Gaussian (LQG) optimal control theory can be used to maximize the average electrical power generated by a vibratory energy harvester subjected to random disturbances. However, feedback controllers designed using the LQG framework often require large peak power flows for their successful implementation, which may be undesirable for several reasons. In this paper, we propose using a risk-sensitive performance measure to synthesize control laws for stochastic vibratory energy harvesters. The proposed methodology is applied in two examples, in which we show how the risk-sensitive parameter can be systematically tuned to maximize power generation and mitigate excessive power flows. The first example involves a simple single-degree-of-freedom oscillator subjected to a bandpass filtered noise excitation, and the second pertains to ocean wave energy harvesting.
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 32 (2) , 351-367
Causal, Stochastic MPC for Wave Energy Converters
We implement a causal model predictive control (MPC) strategy to maximize power generation from a wave energy converter (WEC) system, for which the power take-off (PTO) systems have both hard stroke (i.e., displacement) limits and force ratings. The approach models the WEC dynamics in discrete time, in a manner that exactly preserves energy flow quantities, and assumes a stationary stochastic disturbance model for the incident wave force. The control objective is to maximize the expected power generation in stationarity, while accounting for parasitic losses in the power train. PTO stroke measurements are assumed to be available for real-time feedback, as well as the free surface elevation of the waves at a designated location relative to the WEC, and the open-loop dynamics of the WEC are assumed to be linear and time invariant. Mean-square stability of the MPC algorithm is proven. The methodology is illustrated in a simulation example pertaining to a heaving cylindrical buoy.
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 32 (2) , 351-367
Causal, Stochastic MPC for Wave Energy Converters
We implement a causal model predictive control (MPC) strategy to maximize power generation from a wave energy converter (WEC) system, for which the power take-off (PTO) systems have both hard stroke (i.e., displacement) limits and force ratings. The approach models the WEC dynamics in discrete time, in a manner that exactly preserves energy flow quantities, and assumes a stationary stochastic disturbance model for the incident wave force. The control objective is to maximize the expected power generation in stationarity, while accounting for parasitic losses in the power train. PTO stroke measurements are assumed to be available for real-time feedback, as well as the free surface elevation of the waves at a designated location relative to the WEC, and the open-loop dynamics of the WEC are assumed to be linear and time invariant. Mean-square stability of the MPC algorithm is proven. The methodology is illustrated in a simulation example pertaining to a heaving cylindrical buoy.
- 31 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 29, 2097-2104
Necessary Conditions for Feasibility of Linear, Time-Invariant Self-Powered Feedback Control Laws
A control system is called self-powered if the only energy it requires for operation is that which it absorbs from the plant. For a linear feedback law to be feasible for a self-powered control system, its feedback signal must be colocated with the control inputs, and its input-output mapping must satisfy an associated passivity constraint. In this paper we consider the use of actively-controlled electronics to impose a self-powered linear feedback law. In this case, the feasibility of a linear feedback law must account for parasitic losses in the electronics and energy storage system. For the case in which the feedback law is linear and time-invariant, this paper derives necessary feasibility conditions which explicitly account for these losses. This feasibility condition is then illustrated in a simple example.
- 31 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 29, 2097-2104
Necessary Conditions for Feasibility of Linear, Time-Invariant Self-Powered Feedback Control Laws
A control system is called self-powered if the only energy it requires for operation is that which it absorbs from the plant. For a linear feedback law to be feasible for a self-powered control system, its feedback signal must be colocated with the control inputs, and its input-output mapping must satisfy an associated passivity constraint. In this paper we consider the use of actively-controlled electronics to impose a self-powered linear feedback law. In this case, the feasibility of a linear feedback law must account for parasitic losses in the electronics and energy storage system. For the case in which the feedback law is linear and time-invariant, this paper derives necessary feasibility conditions which explicitly account for these losses. This feasibility condition is then illustrated in a simple example.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 69 (1) , 113-128
On the Feasibility of Self-Powered Linear Feedback Control
A control system is called self-powered if the only energy it requires for operation is that which it absorbs from the plant. For a linear feedback law to be feasible for a self-powered control system, its feedback signal must be colocated with the control inputs, and its input-output mapping must satisfy an associated passivity constraint. The imposition of such a feedback law can be viewed equivalently as the imposition of a linear passive shunt admittance at the actuation ports of the plant. In this paper we consider the use of actively-controlled electronics to impose a self-powered linear feedback law. To be feasible, it is insufficient that the imposed admittance be passive, because parasitic losses must additionally be overcome. We derive sufficient feasibility conditions which explicitly account for these losses. In the finite-dimensional, time-invariant case, the feasibility condition distills to a more conservative version of the Positive Real Lemma, which is parametrized by various loss parameters. Three examples are given, in which this condition is used to determine the least-efficient loss parameters necessary to realize a desired feedback law.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 69 (1) , 113-128
On the Feasibility of Self-Powered Linear Feedback Control
A control system is called self-powered if the only energy it requires for operation is that which it absorbs from the plant. For a linear feedback law to be feasible for a self-powered control system, its feedback signal must be colocated with the control inputs, and its input-output mapping must satisfy an associated passivity constraint. The imposition of such a feedback law can be viewed equivalently as the imposition of a linear passive shunt admittance at the actuation ports of the plant. In this paper we consider the use of actively-controlled electronics to impose a self-powered linear feedback law. To be feasible, it is insufficient that the imposed admittance be passive, because parasitic losses must additionally be overcome. We derive sufficient feasibility conditions which explicitly account for these losses. In the finite-dimensional, time-invariant case, the feasibility condition distills to a more conservative version of the Positive Real Lemma, which is parametrized by various loss parameters. Three examples are given, in which this condition is used to determine the least-efficient loss parameters necessary to realize a desired feedback law.
- 1 January 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Engineering Mechanics
- Vol. 148 (1) , 04021137
Training of a Classifier for Structural Component Failure Based on Hybrid Simulation and Kriging
Hybrid simulation is a tool for investigating the dynamic response of a structural prototype subjected to realistic loading. Hybrid simulation is conducted using a hybrid model that combines physical and numerical substructures interacting with each other in a feedback loop. As a result, the tested substructure interacts with a realistic assembly subjected to a credible loading scenario. In the current practice, experimental results obtained via hybrid simulation support conceptualization and calibration of computational models for structural analysis. Instead, this paper extends the scope of hybrid simulation in constructing a safe/failure state classifier for the tested substructure by adaptively designing a sequence of parametrized hybrid simulations. Such a classifier is intended to compute the state of any physical-substructure-like component within system-level numerical simulations. It follows that the main contribution of this paper lies in the way experimental results are aggregated and integrated with structural analysis. The proposed procedure is experimentally validated for a three-degrees-of-freedom hybrid model subjected to Euler buckling.
- 1 January 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Engineering Mechanics
- Vol. 148 (1) , 04021137
Training of a Classifier for Structural Component Failure Based on Hybrid Simulation and Kriging
Hybrid simulation is a tool for investigating the dynamic response of a structural prototype subjected to realistic loading. Hybrid simulation is conducted using a hybrid model that combines physical and numerical substructures interacting with each other in a feedback loop. As a result, the tested substructure interacts with a realistic assembly subjected to a credible loading scenario. In the current practice, experimental results obtained via hybrid simulation support conceptualization and calibration of computational models for structural analysis. Instead, this paper extends the scope of hybrid simulation in constructing a safe/failure state classifier for the tested substructure by adaptively designing a sequence of parametrized hybrid simulations. Such a classifier is intended to compute the state of any physical-substructure-like component within system-level numerical simulations. It follows that the main contribution of this paper lies in the way experimental results are aggregated and integrated with structural analysis. The proposed procedure is experimentally validated for a three-degrees-of-freedom hybrid model subjected to Euler buckling.