Yang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yang Liu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Zhongwei Huang
4 shared publicationsXixi Zhao
School of Civil and Surveying & Mapping Engineering, Jiangxi University of Science and Technology , Ganzhou 341000
3 shared publicationsLan Huang
School of Civil and Surveying & Mapping Engineering, Jiangxi University of Science and Technolog, Ganzhou, China
2 shared publicationsSiyi Hou
School of Civil and Surveying & Mapping Engineering, Jiangxi University of Science and Technology, Ganzhou, China
2 shared publications- Siyi Hou1 shared publication
Xiaoqing Li
School of Architectural and Surveying and Mapping Engineering, Jiangxi University of Science and Technology, Ganzhou, China
1 shared publication
Latest Publications
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Displacement flow in an enclosure containing multiple buoyancy sources: A review
Buoyancy-driven displacement flow in ventilated enclosures is a key mechanism in natural ventilation, indoor stratification, and contaminant removal. This review provides a structured synthesis of theoretical and experimental studies on displacement flows driven by localized buoyancy sources, focusing on stratified-interface formation and predictive modeling for multiple-source configurations. The review is organized around a unified framework in which buoyant plumes entrain ambient fluid, form layered stratification, and drive unidirectional flow through upper and lower openings. For a single buoyancy source, the classical emptying–filling box model shows that the steady interface height is governed mainly by the dimensionless effective opening area and plume entrainment coefficient, whereas upper-layer buoyancy depends on source strength. For two sources at the same elevation, unequal plumes generate three-layer stratification, with interface positions controlled by opening area, enclosure height, and source-strength ratio. When sources are located at different elevations, additional regimes arise because source position relative to the stratified layers determines which plume supplies the intermediate or upper layer. Representative models are compared in terms of assumptions, governing parameters, treatment of entrainment and mixing, predicted quantities, and applicability. Recent developments involving virtual-source correction, interfacial entrainment, upper-layer depth restrictions, and regime classification are also discussed. By clarifying the relationships, strengths, and limitations of existing models, this review provides guidance for selecting appropriate approaches to predict interface heights, stratification regimes, and ventilation performance in naturally ventilated buildings and related buoyancy-driven flows.
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Displacement flow in an enclosure containing multiple buoyancy sources: A review
Buoyancy-driven displacement flow in ventilated enclosures is a key mechanism in natural ventilation, indoor stratification, and contaminant removal. This review provides a structured synthesis of theoretical and experimental studies on displacement flows driven by localized buoyancy sources, focusing on stratified-interface formation and predictive modeling for multiple-source configurations. The review is organized around a unified framework in which buoyant plumes entrain ambient fluid, form layered stratification, and drive unidirectional flow through upper and lower openings. For a single buoyancy source, the classical emptying–filling box model shows that the steady interface height is governed mainly by the dimensionless effective opening area and plume entrainment coefficient, whereas upper-layer buoyancy depends on source strength. For two sources at the same elevation, unequal plumes generate three-layer stratification, with interface positions controlled by opening area, enclosure height, and source-strength ratio. When sources are located at different elevations, additional regimes arise because source position relative to the stratified layers determines which plume supplies the intermediate or upper layer. Representative models are compared in terms of assumptions, governing parameters, treatment of entrainment and mixing, predicted quantities, and applicability. Recent developments involving virtual-source correction, interfacial entrainment, upper-layer depth restrictions, and regime classification are also discussed. By clarifying the relationships, strengths, and limitations of existing models, this review provides guidance for selecting appropriate approaches to predict interface heights, stratification regimes, and ventilation performance in naturally ventilated buildings and related buoyancy-driven flows.
- 20 February 2024
- Published by Elsevier in Building and Environment
- Vol. 253
Experimental study of buoyancy-driven ventilation with a single opening between two adjacent building zones
- 20 February 2024
- Published by Elsevier in Building and Environment
- Vol. 253
Experimental study of buoyancy-driven ventilation with a single opening between two adjacent building zones
- 10 July 2023
- Published by Springer Nature in Environmental Fluid Mechanics
- Vol. 24 (5) , 845-873
Determination of discharge coefficient in non-Boussinesq cases and application in emptying–filling boxes
- 10 July 2023
- Published by Springer Nature in Environmental Fluid Mechanics
- Vol. 24 (5) , 845-873
Determination of discharge coefficient in non-Boussinesq cases and application in emptying–filling boxes
- Open Access
- 20 January 2023
- Published by Springer Nature in Research Square
Determination of discharge coefficient in non-Boussinesq cases and application in emptying–filling boxes
The effect of high buoyancy forces due to the density contrast between the fluids at either side of the vent on the discharge coefficient Cd was considered in emptying–filling boxes. Salt experiments were conducted at small scale in a large freshwater tank with saline to generate buoyancy force. In non-Boussinesq cases, a larger discharge parameter Γd at the vent may make plume-like flow contract further with a smaller value of the discharge coefficient. Simple draining flows with variant Cd at the upper vent is modeled when considering the emptying of an enclosure initially filled with a large amount of light fluid. The time in the non-dimensional form for draining light fluid fully out of the space for the analysis with a variable value is twice the time predicted with a constant value of Cd = 0.6. A theoretical model of displacement flow with a virtual source correction at the initial position of an internal source was developed to reveal a time-dependent movement of the layer interface, and comparisons were made with the experimental results. The oscillatory amplitude of the interface overshooting during the transient period was found to depend on a geometrical parameter Λ and a dimensionless parameter Θ that characterizes the source strength relative to the space height.
- 20 January 2023
- Published by Springer Nature in Research Square
Open AccessDetermination of discharge coefficient in non-Boussinesq cases and application in emptying–filling boxes
The effect of high buoyancy forces due to the density contrast between the fluids at either side of the vent on the discharge coefficient Cd was considered in emptying–filling boxes. Salt experiments were conducted at small scale in a large freshwater tank with saline to generate buoyancy force. In non-Boussinesq cases, a larger discharge parameter Γd at the vent may make plume-like flow contract further with a smaller value of the discharge coefficient. Simple draining flows with variant Cd at the upper vent is modeled when considering the emptying of an enclosure initially filled with a large amount of light fluid. The time in the non-dimensional form for draining light fluid fully out of the space for the analysis with a variable value is twice the time predicted with a constant value of Cd = 0.6. A theoretical model of displacement flow with a virtual source correction at the initial position of an internal source was developed to reveal a time-dependent movement of the layer interface, and comparisons were made with the experimental results. The oscillatory amplitude of the interface overshooting during the transient period was found to depend on a geometrical parameter Λ and a dimensionless parameter Θ that characterizes the source strength relative to the space height.
- Open Access
- 31 August 2022
- Published by EDP Sciences
- Vol. 356, 04021
Determination of the discharge coefficient through vent driven by a non-Boussinesq plume in an emptying filling box
The effect of high buoyancy forces due to density contrast between the fluids on either side of the vent on the discharge coefficient C d is taken into account in the laboratory. Salt water experiments are conducted at small scale in a large fresh water tank with saline to generate buoyancy force. In non-Boussinesq cases, a larger discharge parameter Γ d at the vent may make plume-like flow contract further with a smaller value of the discharge coefficient. A nearly twofold time in the non-dimensional form for draining light fluid fully out of the space is observed comparing with time predicted with a constant value of C d = 0.6 for simple draining flows. A displacement flow theoretical model with virtual source correction at the initial position of an internal source is developed to reveal a time-dependent movement of the layer interface, and the oscillatory amplitude of the interface overshooting during the transient period is found to depend on the two dimensionless geometrical parameters Λ and Θ.
- 31 August 2022
- Published by EDP Sciences
- Vol. 356, 04021
Open AccessDetermination of the discharge coefficient through vent driven by a non-Boussinesq plume in an emptying filling box
The effect of high buoyancy forces due to density contrast between the fluids on either side of the vent on the discharge coefficient C d is taken into account in the laboratory. Salt water experiments are conducted at small scale in a large fresh water tank with saline to generate buoyancy force. In non-Boussinesq cases, a larger discharge parameter Γ d at the vent may make plume-like flow contract further with a smaller value of the discharge coefficient. A nearly twofold time in the non-dimensional form for draining light fluid fully out of the space is observed comparing with time predicted with a constant value of C d = 0.6 for simple draining flows. A displacement flow theoretical model with virtual source correction at the initial position of an internal source is developed to reveal a time-dependent movement of the layer interface, and the oscillatory amplitude of the interface overshooting during the transient period is found to depend on the two dimensionless geometrical parameters Λ and Θ.
- 24 November 2021
- Published by Springer Nature in Environmental Fluid Mechanics
- Vol. 21 (6) , 1303-1332
Determination of the entrainment coefficient of a pure plume using the salt-bath technique
- 24 November 2021
- Published by Springer Nature in Environmental Fluid Mechanics
- Vol. 21 (6) , 1303-1332
Determination of the entrainment coefficient of a pure plume using the salt-bath technique