Manjunatha Kuruba
Research Subjects
Manjunatha Kuruba has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- M. H. Dinesh
Department of Mechanical Engineering, Government Engineering College, Hassan, India
4 shared publications - D. P. Girish
Department of Mechanical Engineering, Government Engineering College, Hassan, India
2 shared publications Giridhara Gaikwad
B.M.S. College of Engg
2 shared publications- B. M. Santhosh Kumar
Department of Mechanical Engineering, JSS Academy of Technical Education, VTU Belagavi Karnataka, Bengaluru, India
1 shared publication - C. G. Vijay
Department of Mechanical Engineering, JSS Academy of Technical Education, VTU Belagavi Karnataka, Bengaluru, India
1 shared publication D Shivalingappa
B.N.M Institute of Technology
1 shared publication
Latest Publications
- 8 January 2026
- Published by SAGE Publications in Surface Engineering
- Vol. 42 (2) , 188-203
Investigation of mechanical strength of graphene-reinforced hybrid FRP composites
This work integrates graphene oxide (GO) particles with natural and synthetic fabrics to enhance the compression and flexural properties of epoxy-based hybrid composites. Glass fiber (GG), carbon fiber (CC), basalt fiber (BB), and Kevlar fiber (KK), which are renowned for their exceptional material qualities, are combined with GO, which provides significant mechanical advantages, to investigate the composites’ compression and flexural strength. According to ASTM D3410 and ASTM D7264 standards for compression and flexural testing, the study employs vacuum bagging techniques to evaluate several composite formulations’ compression and flexural properties. The results showed substantial flexural and compressive strength increases, particularly when 1% GO was added. The research examines the effect of stacking order and fabric orientation on the flexural and compressive behavior of the composite laminates.Scanning electron microscopy (SEM) was employed to characterize the fractured surfaces and to elucidate the mechanisms responsible for the observed flexural fracture behavior.
- 8 January 2026
- Published by SAGE Publications in Surface Engineering
- Vol. 42 (2) , 188-203
Investigation of mechanical strength of graphene-reinforced hybrid FRP composites
This work integrates graphene oxide (GO) particles with natural and synthetic fabrics to enhance the compression and flexural properties of epoxy-based hybrid composites. Glass fiber (GG), carbon fiber (CC), basalt fiber (BB), and Kevlar fiber (KK), which are renowned for their exceptional material qualities, are combined with GO, which provides significant mechanical advantages, to investigate the composites’ compression and flexural strength. According to ASTM D3410 and ASTM D7264 standards for compression and flexural testing, the study employs vacuum bagging techniques to evaluate several composite formulations’ compression and flexural properties. The results showed substantial flexural and compressive strength increases, particularly when 1% GO was added. The research examines the effect of stacking order and fabric orientation on the flexural and compressive behavior of the composite laminates.Scanning electron microscopy (SEM) was employed to characterize the fractured surfaces and to elucidate the mechanisms responsible for the observed flexural fracture behavior.
- 6 January 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 151 (2) , 1593-1606
Study the performance improvement of shell and tube heat exchanger with graphene nanofluids
- 6 January 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 151 (2) , 1593-1606
Study the performance improvement of shell and tube heat exchanger with graphene nanofluids
- 1 October 2025
- Published by Elsevier in Surfaces and Interfaces
- Vol. 75
Slurry erosion performance of HVOF-sprayed WC-based coatings on Al6061 alloy
- 1 October 2025
- Published by Elsevier in Surfaces and Interfaces
- Vol. 75
Slurry erosion performance of HVOF-sprayed WC-based coatings on Al6061 alloy
- 1 June 2025
- Published by SAGE Publications in Surface Engineering
- Vol. 41 (6) , 647-663
Investigation of tribological performance of HVOF sprayed tungsten carbide coatings
The High Velocity Oxygen-Fuel (HVOF) process has recently increased interest in tungsten carbide (WC) coatings for enhancing surface properties of lightweight alloys such as Al6061, widely used in aerospace, automotive, and industrial applications. In this research work, an investigation into the microstructural characteristics, hardness improvements, Coefficient of friction (COF), and reductions in wear rate of the WC coatings applied at a thickness of 100 microns and 200 microns on Al6061 alloy is discussed. Scanning electron micrographs show a dense and uniform WC layer with minimal porosity. EDAX confirmed the presence of WC and supporting elements. In the case of the 100-micron coating, there was an increase of 337.5% over the base alloy, and in the case of the 200-micron coating, the improvement was 525%. The COF was reduced by 22.5% and 30.9%, and the wear rate decreased by 25% and 41.6% for the respective coating thicknesses.
- 1 June 2025
- Published by SAGE Publications in Surface Engineering
- Vol. 41 (6) , 647-663
Investigation of tribological performance of HVOF sprayed tungsten carbide coatings
The High Velocity Oxygen-Fuel (HVOF) process has recently increased interest in tungsten carbide (WC) coatings for enhancing surface properties of lightweight alloys such as Al6061, widely used in aerospace, automotive, and industrial applications. In this research work, an investigation into the microstructural characteristics, hardness improvements, Coefficient of friction (COF), and reductions in wear rate of the WC coatings applied at a thickness of 100 microns and 200 microns on Al6061 alloy is discussed. Scanning electron micrographs show a dense and uniform WC layer with minimal porosity. EDAX confirmed the presence of WC and supporting elements. In the case of the 100-micron coating, there was an increase of 337.5% over the base alloy, and in the case of the 200-micron coating, the improvement was 525%. The COF was reduced by 22.5% and 30.9%, and the wear rate decreased by 25% and 41.6% for the respective coating thicknesses.
- 25 March 2025
- Published by Springer Nature in Journal of Bio- and Tribo-Corrosion
- Vol. 11 (2) , 1-21
Taguchi-Based Analysis of Wear Performance in SLA Printed Boron Nitride Composites
- 25 March 2025
- Published by Springer Nature in Journal of Bio- and Tribo-Corrosion
- Vol. 11 (2) , 1-21
Taguchi-Based Analysis of Wear Performance in SLA Printed Boron Nitride Composites
- 5 December 2024
- Published by SAGE Publications in Surface Engineering
- Vol. 41 (1) , 92-105
Effect of TiN-TiCN-Al2O3 multilayer coatings on machining characterization deposited by CVD method
In this work, a multilayer Chemical Vapour Deposition (CVD) coating over a base tool material is developed, and its performance in cutting tailored hard EN8 steel is investigated. Using atmospheric pressure chemical vapor deposition, the TiN-TiCN-Al2O3-TiN coating is created on the TNMG 160408 base material. During deposition, 900 m-Torr of deposition pressure and 800 °C of temperature are maintained. Energy-dispersive X-ray analysis (EDAX) is used to inspect the coated instrument to ensure the desired chemical composition is present. According to experimental findings, when cutting speed increases, surface roughness and thrust force decrease. When feed rate and depth of cut are adjusted in tandem with cutting speed, tool wear increases as cutting speed increases. ANOVA variance analysis is carried out while taking into account the maximum dependence of temperature, torque, tool wear, surface roughness, thrust force, and cutting speed on feed rate. Chip analysis is performed at varying speeds of 140, 200, and 260 mm/min, increasing the working conditions results in longer continuous chips. Chips with helical and tubular shapes can be created at cutting rates of 200 mm/min and a depth of cut of 1 mm, respectively.
- 5 December 2024
- Published by SAGE Publications in Surface Engineering
- Vol. 41 (1) , 92-105
Effect of TiN-TiCN-Al2O3 multilayer coatings on machining characterization deposited by CVD method
In this work, a multilayer Chemical Vapour Deposition (CVD) coating over a base tool material is developed, and its performance in cutting tailored hard EN8 steel is investigated. Using atmospheric pressure chemical vapor deposition, the TiN-TiCN-Al2O3-TiN coating is created on the TNMG 160408 base material. During deposition, 900 m-Torr of deposition pressure and 800 °C of temperature are maintained. Energy-dispersive X-ray analysis (EDAX) is used to inspect the coated instrument to ensure the desired chemical composition is present. According to experimental findings, when cutting speed increases, surface roughness and thrust force decrease. When feed rate and depth of cut are adjusted in tandem with cutting speed, tool wear increases as cutting speed increases. ANOVA variance analysis is carried out while taking into account the maximum dependence of temperature, torque, tool wear, surface roughness, thrust force, and cutting speed on feed rate. Chip analysis is performed at varying speeds of 140, 200, and 260 mm/min, increasing the working conditions results in longer continuous chips. Chips with helical and tubular shapes can be created at cutting rates of 200 mm/min and a depth of cut of 1 mm, respectively.
- 20 May 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
- Vol. 236 (12) , 2372-2383
Hot-corrosion behaviour of CNT reinforced Cr 3 C 2 -NiCr coatings working under high-temperature sprayed by HVOF method
The thermal power plant boiler tubes experience degradation of their surfaces due to oxidation and molten salt corrosion while working at elevated temperatures. The formation of protective coating layers can overcome such surface degradation. In the current research, protective coated layers composed of Cr 3 C 2 -25% NiCr/Carbon nanotube coatings are deposited on the ASTM SA-213T12 boiler tube substrate by the High-Velocity Oxy-Fuel (HVOF) thermal method. The coating powder Cr 3 C 2 -25%NiCr is reinforced with 3, 5 and 7 wt% of Multi-Wall Carbon Nano-Tube (MWCNT) prior to deposition. The uncoated and coated specimens are evaluated for hot corrosion behaviour in the molten salt environment (Na 2 SO 4 + 60%V 2 O 5 ) for 50 cycles, constituting 1 h of heating at 600 °C. Thermogravimetric analysis is used to investigate the kinetics of hot corrosion behaviour in both coated and uncoated samples. Coatings are characterized with the help of X-ray diffraction and Scanning Electron Microscope/Energy Dispersive Spectroscopy (SEM/EDS) techniques. Microstructural investigations with the help of SEM/EDS and X-ray diffraction of coated and uncoated samples revealed that 7 wt% of CNT coated samples minimized the voids and pores of the coatings, leading to better interlocking with the substrate surface. Furthermore, it is observed in the studies that the appreciable corrosion resistance of 7 wt% of CNT composite coatings is higher than 3 and 5 wt% of CNT-coated and uncoated samples.
- 20 May 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
- Vol. 236 (12) , 2372-2383
Hot-corrosion behaviour of CNT reinforced Cr 3 C 2 -NiCr coatings working under high-temperature sprayed by HVOF method
The thermal power plant boiler tubes experience degradation of their surfaces due to oxidation and molten salt corrosion while working at elevated temperatures. The formation of protective coating layers can overcome such surface degradation. In the current research, protective coated layers composed of Cr 3 C 2 -25% NiCr/Carbon nanotube coatings are deposited on the ASTM SA-213T12 boiler tube substrate by the High-Velocity Oxy-Fuel (HVOF) thermal method. The coating powder Cr 3 C 2 -25%NiCr is reinforced with 3, 5 and 7 wt% of Multi-Wall Carbon Nano-Tube (MWCNT) prior to deposition. The uncoated and coated specimens are evaluated for hot corrosion behaviour in the molten salt environment (Na 2 SO 4 + 60%V 2 O 5 ) for 50 cycles, constituting 1 h of heating at 600 °C. Thermogravimetric analysis is used to investigate the kinetics of hot corrosion behaviour in both coated and uncoated samples. Coatings are characterized with the help of X-ray diffraction and Scanning Electron Microscope/Energy Dispersive Spectroscopy (SEM/EDS) techniques. Microstructural investigations with the help of SEM/EDS and X-ray diffraction of coated and uncoated samples revealed that 7 wt% of CNT coated samples minimized the voids and pores of the coatings, leading to better interlocking with the substrate surface. Furthermore, it is observed in the studies that the appreciable corrosion resistance of 7 wt% of CNT composite coatings is higher than 3 and 5 wt% of CNT-coated and uncoated samples.
- 18 November 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
- Vol. 236 (1) , 86-96
Effect of carbon nanotubes on microhardness and adhesion strength of high-velocity oxy-fuel sprayed NiCr–Cr3C2 coatings
NiCr–Cr3C2 coatings are widely used for high temperature and tribological applications due to their high hardness, oxidation, and wear resistance properties. In the present investigation, an attempt is made to further enhance the hardness and adhesion strength of NiCr–Cr3C2 coatings by reinforcing them with multi-walled carbon nanotubes. The carbon nanotubes (3–7 wt%) with varying weight percentages were mixed with NiCr–Cr3C2 using a planetary ball rolling mill and sprayed on SA213 T12 (T12 alloy steel tube) using a high-velocity oxy-fuel spraying process. The microstructures of mixed powder, coating cross-section, and fractured coating surface were characterized using a scanning electron microscope while X-ray diffraction was used for phase identification in the fractured coating surface. The coated samples were subjected to microhardness and adhesion strength tests according to ASTM E384 and ASTM D4541-09 standards. Out of all coatings, NiCr–Cr3C2/7% carbon nanotube composite coating showed the lowest porosity of 1.17%, highest microhardness, and adhesion strength of 563.8 HV and 55.8 MPa, respectively. A fracture analysis after a pull-off adhesion test revealed adhesion failure for NiCr–Cr3C2 coating and combined adhesion/cohesion failure for NiCr–Cr3C2/7% carbon nanotube composite coating.
- 18 November 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
- Vol. 236 (1) , 86-96
Effect of carbon nanotubes on microhardness and adhesion strength of high-velocity oxy-fuel sprayed NiCr–Cr3C2 coatings
NiCr–Cr3C2 coatings are widely used for high temperature and tribological applications due to their high hardness, oxidation, and wear resistance properties. In the present investigation, an attempt is made to further enhance the hardness and adhesion strength of NiCr–Cr3C2 coatings by reinforcing them with multi-walled carbon nanotubes. The carbon nanotubes (3–7 wt%) with varying weight percentages were mixed with NiCr–Cr3C2 using a planetary ball rolling mill and sprayed on SA213 T12 (T12 alloy steel tube) using a high-velocity oxy-fuel spraying process. The microstructures of mixed powder, coating cross-section, and fractured coating surface were characterized using a scanning electron microscope while X-ray diffraction was used for phase identification in the fractured coating surface. The coated samples were subjected to microhardness and adhesion strength tests according to ASTM E384 and ASTM D4541-09 standards. Out of all coatings, NiCr–Cr3C2/7% carbon nanotube composite coating showed the lowest porosity of 1.17%, highest microhardness, and adhesion strength of 563.8 HV and 55.8 MPa, respectively. A fracture analysis after a pull-off adhesion test revealed adhesion failure for NiCr–Cr3C2 coating and combined adhesion/cohesion failure for NiCr–Cr3C2/7% carbon nanotube composite coating.