Zhiwei Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhiwei Liang has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Ancheng Luo
3 shared publicationsChisheng Yu
College of Environmental and Resource Sciences, Zhejiang University, 866 Yuhangtang Road, Hangzhou 310058, China
3 shared publicationsLin Qiang
Zhejiang Univ, Coll Environm & Resource Sci, Hangzhou, Peoples R China
2 shared publicationsLuo Ancheng
Zhejiang Univ, Coll Environm & Resource Sci, Hangzhou, Peoples R China
2 shared publicationsQiang Lin
2 shared publicationsShangyuan Yang
2 shared publications
Latest Publications
- 16 July 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
Coordination-Diverse Fe-N 4 Single-Atom Catalysts Regulate High-Valent Iron–Oxo Generation for Ultrafast Fenton-like Reactions
In practical catalyst synthesis, single-atom catalysts (SACs) typically possess complex coordination environments, where multiple coordination configurations coexist within a single catalyst. However, the mechanisms of these diverse coordination structures during oxidant activation and reactive oxygen species (ROS) generation remain largely unclear, hindering the rational design of SACs with controllable ROS pathways. Herein, we developed a SAC based on sludge-based activated carbon (SBAC-SAC) that simultaneously stabilized three Fe coordination configurations (Fe-N4, Fe2N6, and 2Fe-N4) for efficient peracetic acid (PAA) activation. The optimized SBAC-SAC/PAA system achieved rapid phenol degradation with an apparent rate constant of 1.9829 min-1 and 86.12% PAA utilization efficiency. Theoretical calculations further revealed that the Fe2N6 configuration, with a narrowed band gap and high Fe spin states, achieved an optimal balance between adsorption strength and electron transfer for the formation of high-valent iron-oxo species compared with other configurations. The long-term steady operation demonstrated outstanding stability in continuous-flow applications, maintaining 100% removal efficiency for 312 h with negligible iron leaching. Life cycle assessment (LCA) showed the feasibility and environmental promise of this catalyst for practical wastewater treatment. This work provides fundamental insights into the catalytic roles of coordination-diverse Fe-N4 sites and offers a sustainable strategy for designing SACs toward efficient environmental remediation.
- 16 July 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
Coordination-Diverse Fe-N 4 Single-Atom Catalysts Regulate High-Valent Iron–Oxo Generation for Ultrafast Fenton-like Reactions
In practical catalyst synthesis, single-atom catalysts (SACs) typically possess complex coordination environments, where multiple coordination configurations coexist within a single catalyst. However, the mechanisms of these diverse coordination structures during oxidant activation and reactive oxygen species (ROS) generation remain largely unclear, hindering the rational design of SACs with controllable ROS pathways. Herein, we developed a SAC based on sludge-based activated carbon (SBAC-SAC) that simultaneously stabilized three Fe coordination configurations (Fe-N4, Fe2N6, and 2Fe-N4) for efficient peracetic acid (PAA) activation. The optimized SBAC-SAC/PAA system achieved rapid phenol degradation with an apparent rate constant of 1.9829 min-1 and 86.12% PAA utilization efficiency. Theoretical calculations further revealed that the Fe2N6 configuration, with a narrowed band gap and high Fe spin states, achieved an optimal balance between adsorption strength and electron transfer for the formation of high-valent iron-oxo species compared with other configurations. The long-term steady operation demonstrated outstanding stability in continuous-flow applications, maintaining 100% removal efficiency for 312 h with negligible iron leaching. Life cycle assessment (LCA) showed the feasibility and environmental promise of this catalyst for practical wastewater treatment. This work provides fundamental insights into the catalytic roles of coordination-diverse Fe-N4 sites and offers a sustainable strategy for designing SACs toward efficient environmental remediation.
- Open Access
- 5 August 2024
- Published by Elsevier in Environmental Technology & Innovation
- Vol. 36
Reevaluating biostimulation strategies: the impact of humic acid on ofloxacin bioadsorption
- 5 August 2024
- Published by Elsevier in Environmental Technology & Innovation
- Vol. 36
Open AccessReevaluating biostimulation strategies: the impact of humic acid on ofloxacin bioadsorption
- 23 April 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 931, 172686
Occurrence of micropollutants in rural domestic wastewater in Zhejiang Province, China and corresponding wastewater-based epidemiology analysis
- 23 April 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 931, 172686
Occurrence of micropollutants in rural domestic wastewater in Zhejiang Province, China and corresponding wastewater-based epidemiology analysis
- 1 September 2022
- Published by Elsevier in International Biodeterioration & Biodegradation
- Vol. 174
Deciphering autotrophic and heterotrophic partial nitrification under salinity stress
- 1 September 2022
- Published by Elsevier in International Biodeterioration & Biodegradation
- Vol. 174
Deciphering autotrophic and heterotrophic partial nitrification under salinity stress
- Open Access
- 23 December 2021
- Published by Hindawi Limited in Mathematical Problems in Engineering
- Vol. 2021, 1-18
Employing Artificial Neural Networks to Predict the Performance of Domestic Sewage Treatment Terminals in the Rural Region
Domestic sewage in rural regions is mainly treated by small-scale treatment terminals in China. The large quantities and high dispersion of these terminals render the chemical measurement of effluent to be a time and energy intensive work and further hinder the efficient surveillance of terminals performance. After a thorough investigation of 136 operating terminals, this study successfully employs two artificial neural network (ANN) models to predict effluent total nitrogen (TN) and COD (R2 both higher than 0.8) by setting some easily detectable parameters, e.g., pH and conductivity, as inputs. To prevent ANN models getting stuck on local optima and enhance the model performance, genetic algorithm (GA) and particle swarm optimization (PSO) are introduced into ANN, respectively. By comparison, ANN-PSO excels in modelling both TN and COD. The root mean square error (RMSE) and R2 of ANN-PSO in modelling TN are 9.14 and 0.90, respectively, in the training stage, and 11.54 and 0.90, respectively, in the validation stage. The RMSE and R2 of ANN-PSO in modelling COD are 22.10 and 0.90, respectively, in the training stage, and 26.57and 0.85, respectively, in the validation stage. This is the first study to provide performance prediction models that are available for different terminals. Two established ANN-PSO models show great practical significance in monitoring huge amounts of terminals despite the slight sacrifice of models accuracy caused by the great heterogeneity of different terminals.
- 23 December 2021
- Published by Hindawi Limited in Mathematical Problems in Engineering
- Vol. 2021, 1-18
Open AccessEmploying Artificial Neural Networks to Predict the Performance of Domestic Sewage Treatment Terminals in the Rural Region
Domestic sewage in rural regions is mainly treated by small-scale treatment terminals in China. The large quantities and high dispersion of these terminals render the chemical measurement of effluent to be a time and energy intensive work and further hinder the efficient surveillance of terminals performance. After a thorough investigation of 136 operating terminals, this study successfully employs two artificial neural network (ANN) models to predict effluent total nitrogen (TN) and COD (R2 both higher than 0.8) by setting some easily detectable parameters, e.g., pH and conductivity, as inputs. To prevent ANN models getting stuck on local optima and enhance the model performance, genetic algorithm (GA) and particle swarm optimization (PSO) are introduced into ANN, respectively. By comparison, ANN-PSO excels in modelling both TN and COD. The root mean square error (RMSE) and R2 of ANN-PSO in modelling TN are 9.14 and 0.90, respectively, in the training stage, and 11.54 and 0.90, respectively, in the validation stage. The RMSE and R2 of ANN-PSO in modelling COD are 22.10 and 0.90, respectively, in the training stage, and 26.57and 0.85, respectively, in the validation stage. This is the first study to provide performance prediction models that are available for different terminals. Two established ANN-PSO models show great practical significance in monitoring huge amounts of terminals despite the slight sacrifice of models accuracy caused by the great heterogeneity of different terminals.
- 20 April 2021
- Published by Springer Nature in Biodegradation
- Vol. 32 (4) , 403-418
Effect on simultaneous removal of ammonia, nitrate, and phosphorus via advanced stacked assembly biological filter for rural domestic sewage treatment
The discharge of ammonia–nitrogen (NH3–N), total nitrogen (TN), chemical oxygen demand (COD), and total phosphorus (TP) in rural sewage usually exceeds the Pollutant Discharge Standard for Urban Sewage Treatment Plants (GB18918-2002). Efficient and cost-effective removal of these pollutants cannot be simultaneously realized using conventional rural sewage treatment methods. Thus, an assembled biological filter (D50 × W50 × H113 cm), including a phosphorus removal layer filled with solid polymeric ferric sulfate and alternating aerobic-anaerobic layers, is proposed herein. The aerobic (anerobic) layers were filled with zeolite (zeolite and composite soil) at different intervals. This system was used for the treatment of synthetic sewage having COD: 122.0–227.0 mg/L; NH3–N: 29.1–47.0 mg/L; TN: 28.0–58.0 mg/L; and TP: 2.0–3.8 mg/L. Based on optimal operation conditions (40 L/h reflow rate, without artificial aeration, and 12-h operation cycle), the system showed NH3–N, TN, COD, and TP removal efficiencies of 87.1 ± 8.1, 83.4 ± 7.9, 91.0 ± 9.4, and 80.0 ± 6.4%, respectively. Further, in the pilot-scale test, under the same optimal parameters, the removal efficiencies of NH3–N, TN, COD, and TP were 78.9 ± 8.1, 75.4 ± 7.9, 82 ± 9.4, and 76 ± 6.4%, respectively. Furthermore, in the different functional units of the system, a large number of functional bacteria capable of efficiently facilitating the simultaneous removal of the different pollutants from sewage were identified. Therefore, this proposed system, which complies with current environmental discharge regulations, can be a more sustainable approach for the treatment of unattended rural sewage. Graphic abstract
- 20 April 2021
- Published by Springer Nature in Biodegradation
- Vol. 32 (4) , 403-418
Effect on simultaneous removal of ammonia, nitrate, and phosphorus via advanced stacked assembly biological filter for rural domestic sewage treatment
The discharge of ammonia–nitrogen (NH3–N), total nitrogen (TN), chemical oxygen demand (COD), and total phosphorus (TP) in rural sewage usually exceeds the Pollutant Discharge Standard for Urban Sewage Treatment Plants (GB18918-2002). Efficient and cost-effective removal of these pollutants cannot be simultaneously realized using conventional rural sewage treatment methods. Thus, an assembled biological filter (D50 × W50 × H113 cm), including a phosphorus removal layer filled with solid polymeric ferric sulfate and alternating aerobic-anaerobic layers, is proposed herein. The aerobic (anerobic) layers were filled with zeolite (zeolite and composite soil) at different intervals. This system was used for the treatment of synthetic sewage having COD: 122.0–227.0 mg/L; NH3–N: 29.1–47.0 mg/L; TN: 28.0–58.0 mg/L; and TP: 2.0–3.8 mg/L. Based on optimal operation conditions (40 L/h reflow rate, without artificial aeration, and 12-h operation cycle), the system showed NH3–N, TN, COD, and TP removal efficiencies of 87.1 ± 8.1, 83.4 ± 7.9, 91.0 ± 9.4, and 80.0 ± 6.4%, respectively. Further, in the pilot-scale test, under the same optimal parameters, the removal efficiencies of NH3–N, TN, COD, and TP were 78.9 ± 8.1, 75.4 ± 7.9, 82 ± 9.4, and 76 ± 6.4%, respectively. Furthermore, in the different functional units of the system, a large number of functional bacteria capable of efficiently facilitating the simultaneous removal of the different pollutants from sewage were identified. Therefore, this proposed system, which complies with current environmental discharge regulations, can be a more sustainable approach for the treatment of unattended rural sewage. Graphic abstract
- 23 December 2014
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 99 (8) , 3673-3683
The structure and component characteristics of partial nitrification biofilms under autotrophic and heterotrophic conditions
The differences in the structure and component characteristics of partial nitrification biofilms between autotrophic and heterotrophic conditions were investigated in this work. Three-dimensional excitation–emission matrix fluorescence spectroscopy (EEM), fluorescence staining, and confocal laser scanning microscopy (CLSM) were used to determine differences in the architecture and extracellular polymeric substance (EPS) distribution of the autotrophic and heterotrophic biofilms. Partial nitrification was successfully achieved, and the results demonstrated that an appropriate amount of organic carbon (chemical oxygen demand (COD)/N = 2.6) is advantageous for obtaining better partial nitrification. The final ammoniation and nitrosation rates achieved were 97 and 99 %, respectively. Proteins (PN) and polysaccharides (PS) were dominant in the tightly bound EPS (TB-EPS) of autotrophic and heterotrophic biofilms, with PN/PS ratios of 0.96 and 0.69, respectively. Proteins, lipids, α-d-glucopyranose polysaccharides, and nucleic acids were mostly present within the layers of biofilms, but they were distributed in the upper-middle portion of the autotrophic biofilm and increased with depth from the upper layer in the heterotrophic biofilms.
- 23 December 2014
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 99 (8) , 3673-3683
The structure and component characteristics of partial nitrification biofilms under autotrophic and heterotrophic conditions
The differences in the structure and component characteristics of partial nitrification biofilms between autotrophic and heterotrophic conditions were investigated in this work. Three-dimensional excitation–emission matrix fluorescence spectroscopy (EEM), fluorescence staining, and confocal laser scanning microscopy (CLSM) were used to determine differences in the architecture and extracellular polymeric substance (EPS) distribution of the autotrophic and heterotrophic biofilms. Partial nitrification was successfully achieved, and the results demonstrated that an appropriate amount of organic carbon (chemical oxygen demand (COD)/N = 2.6) is advantageous for obtaining better partial nitrification. The final ammoniation and nitrosation rates achieved were 97 and 99 %, respectively. Proteins (PN) and polysaccharides (PS) were dominant in the tightly bound EPS (TB-EPS) of autotrophic and heterotrophic biofilms, with PN/PS ratios of 0.96 and 0.69, respectively. Proteins, lipids, α-d-glucopyranose polysaccharides, and nucleic acids were mostly present within the layers of biofilms, but they were distributed in the upper-middle portion of the autotrophic biofilm and increased with depth from the upper layer in the heterotrophic biofilms.
- 1 February 2014
- Published by Wiley in Water Environment Research
- Vol. 86 (2) , 156-162
Chemical Oxygen Demand Removal Efficiency and Limited Factors Study of Aminosilicone Polymers in a Water Emulsion by Iron–Carbon Micro‐Electrolysis
Micro‐electrolysis was applied in the present study to investigate the effect of pH, iron–carbon mass ratio, contact time, and treatment batch on the removal efficiency of chemical oxygen demand (COD) within an aminosilicone emulsion. The results exhibited that the removal efficiency of COD decreased linearly with the batch increase, and this tendency was consistent under the various conditions. The adsorption of activated carbons contributes a large portion to the elimination of COD within the aminosilicone emulsion. The oxidation action of iron–carbon micro‐electrolysis was proven and the aminosilicone emulsion's COD removal contribution was approximately 16%. Aminosilicone polymers were adsorbed on the surface of activated carbons and iron chips, which contributes to the decline of COD removal efficiency and limits the contribution of oxidation action.
- 1 February 2014
- Published by Wiley in Water Environment Research
- Vol. 86 (2) , 156-162
Chemical Oxygen Demand Removal Efficiency and Limited Factors Study of Aminosilicone Polymers in a Water Emulsion by Iron–Carbon Micro‐Electrolysis
Micro‐electrolysis was applied in the present study to investigate the effect of pH, iron–carbon mass ratio, contact time, and treatment batch on the removal efficiency of chemical oxygen demand (COD) within an aminosilicone emulsion. The results exhibited that the removal efficiency of COD decreased linearly with the batch increase, and this tendency was consistent under the various conditions. The adsorption of activated carbons contributes a large portion to the elimination of COD within the aminosilicone emulsion. The oxidation action of iron–carbon micro‐electrolysis was proven and the aminosilicone emulsion's COD removal contribution was approximately 16%. Aminosilicone polymers were adsorbed on the surface of activated carbons and iron chips, which contributes to the decline of COD removal efficiency and limits the contribution of oxidation action.
- 9 January 2014
- Published by Taylor & Francis in Environmental Technology
- Vol. 35 (11) , 1427-1435
Performance and membrane fouling characteristics of a combined biofilm and membrane bioreactor for treatment of fluorescent whitening agent wastewater
A full-scale system, composed of one anoxic fixed biofilm reactor, four oxic fixed biofilm reactors and an activated sludge membrane bioreactor, was used to treat heavily organic loaded, high toxic and saline fluorescent whitening agent wastewater. This system was running steady during the experimental period of three months. Treatment performance and membrane fouling characteristics were investigated. The concentrations of chemical oxygen demand (COD), , and total nitrogen (TN) in effluent were 447, 27, 14 and 114 mg L−1, corresponding to the removal rates of 89%, 76%, 68% and 64%, respectively. A series of analyses, including Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy, confocal laser scanning microscopy, scanning electron microscopy and protein and polysaccharide concentration measurements, represented that the sludge layer formed on the membrane surface contained both organic and inorganic foulants. Polysaccharides in bound extracellullar polymeric substances in mixed liquor were the main contributor to membrane fouling. Off-line tap water rinsing was proved to be a cost-effective method of fouling control.
- 9 January 2014
- Published by Taylor & Francis in Environmental Technology
- Vol. 35 (11) , 1427-1435
Performance and membrane fouling characteristics of a combined biofilm and membrane bioreactor for treatment of fluorescent whitening agent wastewater
A full-scale system, composed of one anoxic fixed biofilm reactor, four oxic fixed biofilm reactors and an activated sludge membrane bioreactor, was used to treat heavily organic loaded, high toxic and saline fluorescent whitening agent wastewater. This system was running steady during the experimental period of three months. Treatment performance and membrane fouling characteristics were investigated. The concentrations of chemical oxygen demand (COD), , and total nitrogen (TN) in effluent were 447, 27, 14 and 114 mg L−1, corresponding to the removal rates of 89%, 76%, 68% and 64%, respectively. A series of analyses, including Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy, confocal laser scanning microscopy, scanning electron microscopy and protein and polysaccharide concentration measurements, represented that the sludge layer formed on the membrane surface contained both organic and inorganic foulants. Polysaccharides in bound extracellullar polymeric substances in mixed liquor were the main contributor to membrane fouling. Off-line tap water rinsing was proved to be a cost-effective method of fouling control.