YLYoung Jeong Lee

Young Jeong Lee

*This is an algorithmically generated author record based on publicly available information.

Young Jeong Lee has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Jeong Hyun Lee

    Department of Otolaryngology-Head and Neck Surgery Soonchunhyang University College of Medicine Bucheon Hospital Bucheon Korea 영구적

    2 shared publications
  • Hyun Tag Kang

    Department of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Korea

    1 shared publication
  • Ji Eun Moon

    Major in Statistics, Graduate School, Chungwoon University, Incheon, Republic of Korea

    1 shared publication
  • Ji Ho Choi

    Department of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, 170, Jomaru-ro, Bucheon 14584, Republic of Korea

    1 shared publication
  • Jong Dae Lee

    Department of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University School of Medicine, Bucheon, Korea

    1 shared publication
  • Jun Yeong Jeong

    Soonchunhyang University College of Medicine, 170 Jomaru-ro, Bucheon 14584, Korea

    1 shared publication

Latest Publications

  • Open Access

    A Case of Zenker’s Diverticulum Who Underwent Secondary Open Diverticulectomy After Failed Rigid Transoral Endoscopic Diverticulotomy

    by Young Jeong Lee, Jeong Hyun Lee, Jun Yeong Jeong, Ki Nam Park

    The traditional approach to diagnosis and management of Zenker’s diverticulum is open surgical treatment. More recently, however, endoscopic technique is also frequently used for Zenker’s diverticulum because it has advantages of shortening operation time, postoperative hospitalization and reducing the complication such as recurrent laryngeal nerve injury. A 75-year-old male, who was diagnosed with Zenker’s diverticulum, underwent a secondary open diverticulectomy after failed attempt at rigid transoral endoscopic diverticulotomy. Here we report this case with a review of literature.

  • Open Access

    Functional Results and Learning Curve of Endoscopic Ossiculoplasty

    by Min Ki Lee, You Young An, Young Jeong Lee, Jeong Hyun Lee, Se A Lee, Jong Dae Lee

    Background and Objectives Endoscopes are recently being used to manage various middle ear surgeries including ossiculoplasty. Here, we investigated hearing results of endoscopic ossiculoplasty and surgeon’ learning curve in gaining endoscopic ossiculoplasty proficiency. We compared the results with those of microscopic ossiculoplasty.Subjects and Method We analyzed 48 patients of ossiculoplasties performed from 2010 to 2020. Patients were divided into three groups: microscopic technique group (n=16); endoscopic early phase group (n=16); endoscopic late phase group (n=16). Operation time and hearing results including postoperative air-bone gap (ABG) and ABG closure were analyzed. Hearing outcomes were considered “successful” when the postoperative ABG was less than 20 dB and considered “excellent” when ABG was less than 10 dB. The learning curve of the outcomes were analyzed.Results Both operation time and postoperative ABG showed decreasing tendency, but only operation time showed statistical significance. The ratio of successful and excellent operations improved, but did not show statistical significance. Improvement in learning curve was not statistically significant presumably due to the lack of patient numbers.Conclusion Surgeon’s proficiency of endoscopic ossiculoplasty was correlated with the improved clinical outcomes, and proficiently conducted endoscopic ossiculoplasty could be used as a surgical technique comparable to microscopic ossiculoplasty.


  • Validation Study of a Contactless Monitoring Device for Vital Signs During Sleep and Sleep Architecture in Adults With Sleep-Disordered Breathing

    by Young Jeong Lee, Hyun Tag Kang, Ji Ho Choi, Ji Eun Moon, Tae Kyung Ha, Ho Dong Lee

    Background and Objective Few clinical studies have investigated the accuracy of non-contact monitoring devices for vital signs during sleep and sleep architecture in adults with sleep-disordered breathing (SDB). The purpose of this study was to assess the accuracy of a contactless monitoring device for 1) heart rate, respiratory rate, and body temperature during sleep and 2) sleep architecture in adults with SDB.Methods Thirty-five consecutive adults, who visited a tertiary university hospital due to suspected SDB, underwent a complete physical examination and standard (level 1) polysomnography plus body temperature measurement with a contactless monitoring device (HoneyCube System).Results A total of 30 subjects (mean age = 46.43 ± 12.9 years; male: female = 22: 8) were finally included, and five subjects were excluded due to inadequate data in this study. The intraclass correlation coefficient values of heart rate, respiratory rate, and body temperature measured using the contactless monitoring device were 0.91 (95% confidence interval [CI]: 0.892, 0.928), 0.937 (95% CI: 0.919, 0.954), and 0.918 (95% CI: 0.895, 0.941), respectively. The mean kappa value for sleep architecture was 0.562 (95% CI: 0.529, 0.596).Conclusions The contactless monitoring device showed good (almost perfect) agreement in terms of heart rate, respiratory rate, and body temperature and moderate agreement in sleep architecture with contact measurements. These results suggest that the HoneyCube System is a good candidate device for sleep monitoring at home and in multiple accommodations.