SBSteffen Bräkling

Steffen Bräkling

*This is an algorithmically generated author record based on publicly available information.

Steffen Bräkling has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Sonja Klee

    TOFWERK AG, Schorenstrasse 39, 3645 Thun, Switzerland

    4 shared publications
  • Hendrik Kersten

    Department of Physical and Theoretical Chemistry, University of Wuppertal, Gauss Str. 20, Wuppertal 42119, Germany

    2 shared publications
  • Kai Kroll

    Department of Physical and Theoretical Chemistry, University of Wuppertal, Gauss Str. 20, Wuppertal 42119, Germany

    2 shared publications
  • Marleen Vetter

    TOFWERK

    2 shared publications
  • Thorsten Benter

    Department of Physical and Theoretical Chemistry, University of Wuppertal, Gaussstraße 20, 42119 Wuppertal, Germany

    2 shared publications
  • Amir Salemi

    Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141 Essen, Germany

    1 shared publication

Latest Publications

  • Performance Evaluation of an EI&CI Dual Ionization TOFMS Hyphenated with a Flow Modulated GC×GC System

    by Steffen Bräkling, Marleen Vetter, Ralf Kurtenbach, Peter Wiesen, Scott J. Campbell, John H. Moncur, Sonja Klee

    The use and compatibility of a dual-ionization TOFMS operating an EI source and a CI source in parallel using a single TOF mass analyzer with flow modulated two-dimensional GC (GC×GC) is described. Important figures of merit of the mass spectrometer that are required for two-dimensional GC hyphenation such as acquisition speed, ion source response, EI/CI switching, the GC transfer, and data alignment are carefully investigated and addressed. Improved fast switching ion optics allow switching in a 100 Hz frequency between EI and CI spectra sampled from the same GC×GC effluent. The spectra quality also influenced by the preseparation, especially of the EI source, is compared to a standard setup operating a single quadrupole MS coupled to the same GC system. Further, two setups including and excluding an additional flame ionization detector are presented. High increments in CI sensitivities are achieved by utilizing the high pumping efficiencies of the CI stage of the used mass spectrometer. By leading high flow ratios of the GC×GC modulation flows toward the CI source, the intensity can be increased by factors of up to 37 while maintaining the pressure balance of the less robust EI source. Finally, thermal desorption GC×GC-EI&CI-TOFMS analyses of traffic emission samples from a federal highway in Germany are executed with the presented setup.


  • Evaluation of GC-EI&CI-TOFMS for Nontarget Analysis of Industrial Wastewater Using Hydrophilic–Lipophilic-Balanced SPME

    by Lucie K. Tintrop, Steffen Bräkling, Marleen Vetter, Willi Eßer, Felix Drees, Amir Salemi, Maik A. Jochmann, Sonja Klee, Torsten C. Schmidt

    The evaluation of nontarget analysis (NTA) techniques for the monitoring of wastewater is important as wastewater is an anthropogenic pollution source for aquatic ecosystems and a threat to human and environmental health. This study presents the proof-of-concept NTA of industrial wastewater samples. A prototype hydrophilic–lipophilic-balanced (HLB) SPME and gas chromatography interfaced with time-of-flight high-resolution mass spectrometry (GC-TOFMS) with electron ionization (EI) and chemical ionization (CI) in parallel are employed. The HLB-SPME consists of a poly(divinylbenzene-co-N-vinylpyrrolidone) structure, allowing the extraction of hydrophilic as well as lipophilic substances. As the combination of parallel CI and EI data provides a comprehensive data set as a unique feature, this study is strongly focused on the compound identification procedure and confidence reporting of exemplary substances. Furthermore, the use of three different CI reagent ions, including [N2H]+/[N4H]+, [H3O]+, and [NH4]+, enables a broad range of analytes to be ionized in terms of selectivity and softness. The complementary information provided by EI and CI data allows a level 3 identification or higher in 69% of cases. The polarity coverage based on the physicochemical properties of the analytes (such as volatility, water solubility, hydrophilicity, and lipophilicity) was visualized by using Henry’s law and octanol–water partitioning constants. In conclusion, the presented approach is shown to be valuable for water analysis and allows enhanced and accelerated compound identification compared to utilizing only one type of ionization.


  • Open Access

    Gas chromatography coupled to time‐of‐flight mass spectrometry using parallel electron and chemical ionization with permeation tube facilitated reagent ion control for material emission analysis

    by Steffen Bräkling, Christina Hinterleitner, Luca Cappellin, Marleen Vetter, Ingo Mayer, Thorsten Benter, Sonja Klee, Hendrik Kersten

    Rationale: Volatile organic compounds (VOCs) emitted by an artificial leather part for car interiors are determined using GC–MS (gas chromatograph coupled to a mass spectrometer) using simultaneous electron and chemical ionization (EI&CI). A device for swift reagent ion switching in CI mode between consecutive runs is presented. Methods: VOCs emitted from the investigated material were sampled onto Tenax® absorption tubes using micro emission chambers and subsequently injected into the GC through thermal desorption. The detector was a time‐of‐flight mass spectrometer (TOFMS) simultaneously operating in EI and CI modes during a single chromatographic run. A custom permeation tube setup allowed for swift selection between various reagent ions in CI mode, e.g., [N 2 H] + , [H 3 O] + , [(H 2 O) 2 H] + , and [NH 4 ] + . Results: Different reagent ions are swiftly selectable between single GC runs without hardware changes. Differences in precursor ion survival yields and the selectivity of the various reactants were carefully assessed. Several examples for the improved identification of unknown compounds with the available complementary and comprehensive EI&CI data set are demonstrated for a relevant material emission application. Conclusion: The presented technique provides additional value to the standard GC‐EI/MS procedure commonly used for material emission characterization. It allows for a non‐targeted analysis approach with moderate analysis time.


  • Parallel Operation of Electron Ionization and Chemical Ionization for GC–MS Using a Single TOF Mass Analyzer

    by Steffen Bräkling, Kai Kroll, Carsten Stoermer, Urs Rohner, Marc Gonin, Thorsten Benter, Hendrik Kersten, Sonja Klee

    This work describes a novel mass spectrometer coupled to gas chromatography (GC–MS) that simultaneously displays the mass spectral information of electron (EI)- and chemical ionization (CI)-generated ion populations for a single chromatographic peak. After GC separation, the eluent is equally split and supplied in parallel to an EI and a novel CI source, both operating continuously. Precise switching of the ion optics provides the exact timing to consecutively extract the respective ion population from both sources and transfer them into a time-of-flight (TOF) mass analyzer. This technique enables the acquisition of complementary information from both ion populations (EI and CI) within a single chromatographic run and with sufficient data points to retain the chromatographic fidelity. The carefully designed GC transfer setup, fast ion optical switching, and synchronized TOF data acquisition system provide an automatic and straightforward spectral alignment of two ion populations. With an eluent split ratio of about 50% between the two ion sources, instrument detection limits of <40 fg on the column (octafluoronaphthalene) for the EI and <2 pg (benzophenone) for the CI source were obtained. The system performance and the additional analytical value for compound identification are demonstrated by means of different common GC standard mixtures and a commercial perfume sample of unknown composition.


  • Hydrogen Plasma-Based Medium Pressure Chemical Ionization Source for GC-TOFMS

    by Steffen Bräkling, Kai Kroll, Sonja Klee, Thorsten Benter, Hendrik Kersten

    The construction, critical evaluation, and performance assessment of a medium-pressure (2–13 mbar), high-temperature chemical ionization (CI) source for application in GC-MS is described. The ion source is coupled to a commercial time-of-flight (TOF) mass analyzer. Reagent ions are generated in a two staged process. The first stage uses a filament free, helical resonator plasma (HRP) driven ion source for H3+ generation. Reagent gases, for example, nitrogen, isobutane, and methane are added in a second stage to the H3+ stream, which leads to the formation of final protonation reagents. The GC effluent is added subsequently to the reagent ion gas stream. Designed for the hyphenation with gas chromatography, this GC-CI-TOFMS combination produces GC limited Gaussian peak shapes even for high boiling point compounds. Limits of detection for the compounds investigated are determined as 0.4–1.2 pg on column with nitrogen, 0.6–12.6 pg with isobutane, and 2 pg to >25 pg with methane as reagent gas, respectively. An EPA 8270 LCS mix containing 78 main EPA pollutants is used to evaluate the selectivity of the different reagent ions. Using nitrogen as reagent gas, 74 of 78 compounds are detected. In comparison, 41 of 78 compounds and 62 of 78 compounds are detected with isobutane or methane as CI reagent gas, respectively.