Xuetong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xuetong Wang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Zhipeng Ma
School of Aeronautics and Astronautics, Zhejiang University, Hangzhou, China
4 shared publications Chenhao Xia
Key Laboratory of Micro-nano Satellite Research of Zhejiang Province, Zhejiang University, Hangzhou 310027, People’s Republic of China
3 shared publications- Xudong Zheng
Zhejiang University
3 shared publications Yaojie Shen
Key Laboratory of Micro-nano Satellite Research of Zhejiang Province, Zhejiang University, Hangzhou 310027, People’s Republic of China
3 shared publicationsWenyuan Tong
Key Laboratory of Micro-nano Satellite Research of Zhejiang Province, Zhejiang University, Hangzhou 310027, People’s Republic of China
2 shared publicationsZhonghe Jin
Key Laboratory of Micro-Nano Satellite Research of Zhejiang Province, Zhejiang University, Hangzhou, China
2 shared publications
Latest Publications
- 27 July 2023
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 33 (9) , 095008
Noise analysis and modeling for a digital control architecture for Lissajous frequency-modulated MEMS gyroscope with amplitude-modulated readout
We report a digital control architecture that demodulates both amplitude-modulated (AM) and frequency-modulated (FM) rate information simultaneously from a gyroscope working in Lissajous frequency-modulated (LFM) mode. The angular rate information is derived from both quadrature (X and Y) resonance modes of the gyroscope simultaneously. A noise model for the AM signal processing channel of the LFM gyroscope is built, analyzed and compared with that of a conventional AM gyroscope, which shows that methods to improve the performance of the conventional AM gyroscope can also be applied to the AM signal processing channel of the LFM gyroscope. The angular rate output obtained from the AM information of the LFM gyroscope has better noise characteristics, which therefore supplements the low precision inadequacy of the FM signal channel of the LFM mode. Tests on the same gyroscope working in different control architectures are conducted. The angle random walk (ARW) and bias instability (BI) of the AM channel of the proposed architecture are 0.51 deg √h−1 and 1.8 deg h−1, respectively, which are better than the results obtained from the FM channel in the same architecture, with values of 0.99 deg √h−1 and 4.3 deg h−1, respectively. Also ARW amd BI of the same gyroscope working in conventional AM mode is 0.50 deg √h−1 and 5.2 deg h−1, respectively.
- 27 July 2023
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 33 (9) , 095008
Noise analysis and modeling for a digital control architecture for Lissajous frequency-modulated MEMS gyroscope with amplitude-modulated readout
We report a digital control architecture that demodulates both amplitude-modulated (AM) and frequency-modulated (FM) rate information simultaneously from a gyroscope working in Lissajous frequency-modulated (LFM) mode. The angular rate information is derived from both quadrature (X and Y) resonance modes of the gyroscope simultaneously. A noise model for the AM signal processing channel of the LFM gyroscope is built, analyzed and compared with that of a conventional AM gyroscope, which shows that methods to improve the performance of the conventional AM gyroscope can also be applied to the AM signal processing channel of the LFM gyroscope. The angular rate output obtained from the AM information of the LFM gyroscope has better noise characteristics, which therefore supplements the low precision inadequacy of the FM signal channel of the LFM mode. Tests on the same gyroscope working in different control architectures are conducted. The angle random walk (ARW) and bias instability (BI) of the AM channel of the proposed architecture are 0.51 deg √h−1 and 1.8 deg h−1, respectively, which are better than the results obtained from the FM channel in the same architecture, with values of 0.99 deg √h−1 and 4.3 deg h−1, respectively. Also ARW amd BI of the same gyroscope working in conventional AM mode is 0.50 deg √h−1 and 5.2 deg h−1, respectively.
- 17 March 2023
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 33 (5) , 055002
Identification and suppression of driving force misalignment angle for a MEMS gyroscope using parametric excitation
We report for the first time an implementable method to identify and suppress the driving force misalignment angle for a MEMS gyroscope working either in amplitude modulated (AM) or Lissajous frequency modulated (LFM) mode using parametric excitation. By introducing driving force misalignment angle into gyroscope dynamic equations, we illustrate that gyroscope angular rate output is affected by driving force misalignment angle and cross-axis damping jointly. We propose parametric excitation as a way to both identify and calculate the driving force misalignment angle. The identification results for a gyroscope working in both AM and LFM mode are similar, which indicates the effectiveness of the proposed identification method. Instead of using traditional amplitude control loop by adjusting the driving force, we do the automatic gain control by adjusting the parametric pump voltage so that a fixed drive voltage can be used, which also indicates fixed force coupling. Experimental results show that after suppression, the bias instability (BI) of AM mode is improved from 4.7° h−1 to 2.3° h−1 and the BI of LFM mode is improved from 1.4° h−1 to 0.9° h−1 which is the lowest result reported for LFM gyroscope.
- 17 March 2023
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 33 (5) , 055002
Identification and suppression of driving force misalignment angle for a MEMS gyroscope using parametric excitation
We report for the first time an implementable method to identify and suppress the driving force misalignment angle for a MEMS gyroscope working either in amplitude modulated (AM) or Lissajous frequency modulated (LFM) mode using parametric excitation. By introducing driving force misalignment angle into gyroscope dynamic equations, we illustrate that gyroscope angular rate output is affected by driving force misalignment angle and cross-axis damping jointly. We propose parametric excitation as a way to both identify and calculate the driving force misalignment angle. The identification results for a gyroscope working in both AM and LFM mode are similar, which indicates the effectiveness of the proposed identification method. Instead of using traditional amplitude control loop by adjusting the driving force, we do the automatic gain control by adjusting the parametric pump voltage so that a fixed drive voltage can be used, which also indicates fixed force coupling. Experimental results show that after suppression, the bias instability (BI) of AM mode is improved from 4.7° h−1 to 2.3° h−1 and the BI of LFM mode is improved from 1.4° h−1 to 0.9° h−1 which is the lowest result reported for LFM gyroscope.
- 13 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (20) , 19207-19219
A Digital Control Structure for Lissajous Frequency-Modulated Mode MEMS Gyroscope
This article proposes a digital control structure for a doubly decoupled gyroscope working in the Lissajous frequency-modulated (LFM) mode based on digital phase-locked loops (PLLs), which demodulates the angular rate signal directly from the readable digital gyroscope resonance frequency, eliminating the need for specific frequency readout circuits. The resonance frequencies of the LFM gyroscope working modes contain a mode mismatch frequency modulated by input angular rate, respectively, which are tracked by two digital PLLs followed by subsequent digital demodulation and filtering. A linearized model of the digital PLL is built to analyze noise and control characteristics for different PI parameters. The impact of different amplitude–phase extraction architectures on the extracted phase signal is also addressed in this article. Contrast experiments are carried out using the same gyroscope with large internal thermal stress due to the silicon-glass bonding process and no stress relief structure around the sensing element, working in the traditional amplitude-modulated (AM) mode and the LFM mode. Overall, the LFM working mode maintains its low-temperature sensitivity and high stability in spite of the large internal thermal stress in the gyroscope compared to AM working modes. The maximum scale factor variation over the temperature range from 10 °C to 50 °C is 1000 ppm for the LFM mode compared to 51 900 ppm for the AM closed mode. The maximum zero rate output drift over the same temperature range is 0.1248 °/s for the LFM mode and 10.7139 °/s for the AM closed mode. The scale factor nonlinearity is 329 ppm with an angular rate input range of ±50 °/s for the LFM mode compared to 1902 ppm for the AM closed mode. The LFM mode zero-bias fluctuation for ten days is less than 0.12 °/s. The angle random walk (ARW) and the bias instability (BI) of the LFM gyroscope are 0.316 °/ $\surd \text{h}$ and 2 °/h, respectively.
- 13 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (20) , 19207-19219
A Digital Control Structure for Lissajous Frequency-Modulated Mode MEMS Gyroscope
This article proposes a digital control structure for a doubly decoupled gyroscope working in the Lissajous frequency-modulated (LFM) mode based on digital phase-locked loops (PLLs), which demodulates the angular rate signal directly from the readable digital gyroscope resonance frequency, eliminating the need for specific frequency readout circuits. The resonance frequencies of the LFM gyroscope working modes contain a mode mismatch frequency modulated by input angular rate, respectively, which are tracked by two digital PLLs followed by subsequent digital demodulation and filtering. A linearized model of the digital PLL is built to analyze noise and control characteristics for different PI parameters. The impact of different amplitude–phase extraction architectures on the extracted phase signal is also addressed in this article. Contrast experiments are carried out using the same gyroscope with large internal thermal stress due to the silicon-glass bonding process and no stress relief structure around the sensing element, working in the traditional amplitude-modulated (AM) mode and the LFM mode. Overall, the LFM working mode maintains its low-temperature sensitivity and high stability in spite of the large internal thermal stress in the gyroscope compared to AM working modes. The maximum scale factor variation over the temperature range from 10 °C to 50 °C is 1000 ppm for the LFM mode compared to 51 900 ppm for the AM closed mode. The maximum zero rate output drift over the same temperature range is 0.1248 °/s for the LFM mode and 10.7139 °/s for the AM closed mode. The scale factor nonlinearity is 329 ppm with an angular rate input range of ±50 °/s for the LFM mode compared to 1902 ppm for the AM closed mode. The LFM mode zero-bias fluctuation for ten days is less than 0.12 °/s. The angle random walk (ARW) and the bias instability (BI) of the LFM gyroscope are 0.316 °/ $\surd \text{h}$ and 2 °/h, respectively.
- 7 March 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (4) , 045003
Comparative analysis and tests for an improved frequency tuning area-varying electrode considering the influence of fringe capacitance
In this paper, an improved area-varying tuning electrode with better immunility to fringe capactor is proposed, analyzed and tested, which is mainly used for frequency tuning of micromechanical gyroscopes. Based on the existing area-varying tuning electrode Hu et al (2013 J. Microelectromech. Syst. 22 909–18), this paper firstly analyzes the capacitance of the tuning electrode, and obtains the relationship between the capacitance and the displacement using both the analytic formula and finite element analysis, verifying that the fringe capacitance in area-varying tuning electrode decreases the tuning ability of both up-tuning electrode and down-tuning electrode. Then, parametric scanning method is used to optimize the geometry parameter of the tuning electrode, which reduces the influence of fringe capacitance and increases the tuning ability of the tuning electrode. Contrast experiments and tests are carried with gyroscope samples with tuning electrodes before and after optimizing. The tested mean value of tuning ability of the improved tuning electrode is improved by 95.7% after opimization.
- 7 March 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (4) , 045003
Comparative analysis and tests for an improved frequency tuning area-varying electrode considering the influence of fringe capacitance
In this paper, an improved area-varying tuning electrode with better immunility to fringe capactor is proposed, analyzed and tested, which is mainly used for frequency tuning of micromechanical gyroscopes. Based on the existing area-varying tuning electrode Hu et al (2013 J. Microelectromech. Syst. 22 909–18), this paper firstly analyzes the capacitance of the tuning electrode, and obtains the relationship between the capacitance and the displacement using both the analytic formula and finite element analysis, verifying that the fringe capacitance in area-varying tuning electrode decreases the tuning ability of both up-tuning electrode and down-tuning electrode. Then, parametric scanning method is used to optimize the geometry parameter of the tuning electrode, which reduces the influence of fringe capacitance and increases the tuning ability of the tuning electrode. Contrast experiments and tests are carried with gyroscope samples with tuning electrodes before and after optimizing. The tested mean value of tuning ability of the improved tuning electrode is improved by 95.7% after opimization.