Muhammad Nadeem Sharif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhammad Nadeem Sharif has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ezzeddin Bakhtavar
School of Engineering and Computer Science, Laurentian University, Sudbury, Canada
1 shared publication Guangji Hu
School of Engineering, University of British Columbia (Okanagan Campus), Kelowna, Canada
1 shared publicationHusnain Haider
Civil Engineering Department, College of Engineering, Qassim University, Qassim, Buraydah, Saudi Arabia
1 shared publicationKashif Irshad
1 shared publicationKasun Hewage
School of Engineering, University of British Columbia (Okanagan Campus), Kelowna, Canada
1 shared publication- M. Eswara Rao
Department of Mathematics Saveetha School of Engineering, SIMATS Chennai Tamil Nadu India
1 shared publication
Latest Publications
- Open Access
- 1 May 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 59
Williamson MHD nanofluid flow via a porous exponentially stretching sheet with bioconvective fluxes
- 1 May 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 59
Open AccessWilliamson MHD nanofluid flow via a porous exponentially stretching sheet with bioconvective fluxes
- 28 February 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (3) , 1-23
Staged energy and water quality optimization for large water distribution systems
Simultaneous optimization of energy and water quality in real-time large-sized water distribution systems is a daunting task for water suppliers. The complexity of energy optimization increases with a large number of pipes, scheduling of several pumps, and adjustments of tanks’ water levels. Most of the simultaneous energy and water quality optimization approaches evaluate small (or hypothetical) networks or compromise water quality. In the proposed staged approach, Stage 1 uses a risk-based approach to optimally locate the chlorine boosters in a large distribution system based on residual chlorine failures and the associated consequences in different land uses of the service area. Integrating EPANET and CPLEX software, Stage 2 uses mixed integer goal programming for optimizing the day-ahead pump scheduling. The objective function minimizes the pumping energy cost as well as the undesirable deviations from goal constraints, such as expected water demand. Stage 3 evaluates the combined hydraulics and water quality performances at the network level. The implementation of the proposed approach on a real-time large-sized network of Al-Khobar City in Saudi Arabia, with 44 groundwater wells, 12 reservoirs, 2 storage tanks, 191 mains, 141 junctions, and 17 pumps, illustrated the practicality of the framework. Simulating the network with an optimal pumping schedule and chlorine boosters’ locations shows a 40% improvement in water quality performance, desired hydraulics performance with optimal pump scheduling, and an average 20% energy cost reduction compared to the normal (unoptimized) base case scenario.
- 28 February 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (3) , 1-23
Staged energy and water quality optimization for large water distribution systems
Simultaneous optimization of energy and water quality in real-time large-sized water distribution systems is a daunting task for water suppliers. The complexity of energy optimization increases with a large number of pipes, scheduling of several pumps, and adjustments of tanks’ water levels. Most of the simultaneous energy and water quality optimization approaches evaluate small (or hypothetical) networks or compromise water quality. In the proposed staged approach, Stage 1 uses a risk-based approach to optimally locate the chlorine boosters in a large distribution system based on residual chlorine failures and the associated consequences in different land uses of the service area. Integrating EPANET and CPLEX software, Stage 2 uses mixed integer goal programming for optimizing the day-ahead pump scheduling. The objective function minimizes the pumping energy cost as well as the undesirable deviations from goal constraints, such as expected water demand. Stage 3 evaluates the combined hydraulics and water quality performances at the network level. The implementation of the proposed approach on a real-time large-sized network of Al-Khobar City in Saudi Arabia, with 44 groundwater wells, 12 reservoirs, 2 storage tanks, 191 mains, 141 junctions, and 17 pumps, illustrated the practicality of the framework. Simulating the network with an optimal pumping schedule and chlorine boosters’ locations shows a 40% improvement in water quality performance, desired hydraulics performance with optimal pump scheduling, and an average 20% energy cost reduction compared to the normal (unoptimized) base case scenario.