Wei-Jen Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei-Jen Cheng has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Areerat Suputtitada
Department of Rehabilitation Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
1 shared publication - Carl P. C. Chen
Department of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital at Linkou, College of Medicine, Chang Gung University, Guishan District, Taoyuan City 33343, Taiwan
1 shared publication - Chao-Jan Wang
Department of Medical Imaging and Intervention, Taoyuan, Taiwan
1 shared publication Chih-Chi Chen
Department of Physical Medicine & Rehabilitation, Chang Gung Memorial Hospital at Linkou and College of Medicine, Chang Gung University, Guishan District, Taoyuan City, Taiwan
1 shared publication- Chin-Man Wang
Department of Rehabilitation, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan 33302, Taiwan
1 shared publication - Jean-Lon Chen
Department of Physical Medicine & Rehabilitation, Chang Gung Memorial Hospital at Linkou, College of Medicine, Chang Gung University, Guishan District, Taoyuan City 33343, Taiwan
1 shared publication
Latest Publications
- Open Access
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 6496382
Thermal Oscillation Changes the Liquid‐Form Autologous Platelet‐Rich Plasma into Paste‐Like Form
Objectives. The texture of the autologous platelet‐rich plasma (PRP) that is used in treating degenerative joint diseases such as knee osteoarthritis (OA) is usually in liquid form. However, the turnover rate of protein metabolism in the knee synovial fluid (SF) is less than one hour. This study examined the feasibility of the thermal oscillation technique in converting the liquid‐form PRP into an injectable viscous paste‐like PRP that may delay the degradation of PRP and continuously release growth factors in the knee joint for a longer period of time. Methods. This study was conducted in the rehabilitation department of a tertiary hospital. A total of 10 elderly patients with an average age of greater than 65 years and diagnosed with moderate degree of knee OA were recruited. The RegenPRP (RegenLab, Le Mont‐sur‐Lausanne, Switzerland) test tube chamber was used for PRP generation. A total of 60 milliliters (mL) of blood was drawn from each patient. 10 mL of blood was injected into each PRP test tube chamber. As a result, a total of 6 test tube chambers were obtained and each chamber was centrifuged for 15 minutes. Approximately 5 mL of PRP supernatant (the liquid‐form end product) was aspirated and sent for thermal oscillation treatment. Five temperatures were tested: 55, 65, 75, 85, and 95 degrees Celsius. Oscillation was set at 200 revolutions per minute (rpm) for 15 minutes. The enzyme‐linked immunosorbent assay (ELISA) was applied in measuring the concentration of platelet‐derived growth factor (PDGF) in picogram/milliliter (pg/mL). Repeated measures ANOVA followed by the Bonferroni post hoc test was used to compare the PDGF concentrations between each testing condition. Results. Under 75 degrees Celsius of heating, the resultant paste‐like PRP end product had the highest concentration of PDGF in picograms per milliliter (pg/mL) as compared with other heating conditions (p < 0.05). The viscosity of the paste‐like PRP was measured to be 70,000 centipoise (cP), which is similar to the viscosity of a toothpaste. The paste‐like PRP end product was able to release PDGF continuously for about 14 days, with the highest concentration achieved on the 8th day with an average of 35646 ± 2499 pg/mL. In nonthermally treated liquid‐form PRP sample, the highest number of PRP was observed on the 4th day with an average value of 8444 ± 831 pg/mL. Under the heating conditions of 55 and 95 degrees Celsius, the highest concentration of PDGF was observed on the 5th day (13346 ± 764 pg/mL and 3440 ± 303 pg/mL, respectively). Under the heating conditions of 65 and 85 degrees Celsius, the highest concentration of PDGF was observed on the 7th day (15468 ± 744 pg/mL and 20432 ± 1118 pg/mL, respectively). Conclusion. Through thermal oscillation, liquid‐form PRP can be converted to paste‐like PRP end product with a viscosity similar to that of a toothpaste. The best heating condition was discovered to be 75 degrees Celsius. The paste‐like PRP was able to release PDGF continuously for about 2 weeks, with the highest concentration obtained on the 8th day. The findings in this study suggested that paste‐like PRP may be a viable option in treating degenerative knee joint diseases.
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 6496382
Open AccessThermal Oscillation Changes the Liquid‐Form Autologous Platelet‐Rich Plasma into Paste‐Like Form
Objectives. The texture of the autologous platelet‐rich plasma (PRP) that is used in treating degenerative joint diseases such as knee osteoarthritis (OA) is usually in liquid form. However, the turnover rate of protein metabolism in the knee synovial fluid (SF) is less than one hour. This study examined the feasibility of the thermal oscillation technique in converting the liquid‐form PRP into an injectable viscous paste‐like PRP that may delay the degradation of PRP and continuously release growth factors in the knee joint for a longer period of time. Methods. This study was conducted in the rehabilitation department of a tertiary hospital. A total of 10 elderly patients with an average age of greater than 65 years and diagnosed with moderate degree of knee OA were recruited. The RegenPRP (RegenLab, Le Mont‐sur‐Lausanne, Switzerland) test tube chamber was used for PRP generation. A total of 60 milliliters (mL) of blood was drawn from each patient. 10 mL of blood was injected into each PRP test tube chamber. As a result, a total of 6 test tube chambers were obtained and each chamber was centrifuged for 15 minutes. Approximately 5 mL of PRP supernatant (the liquid‐form end product) was aspirated and sent for thermal oscillation treatment. Five temperatures were tested: 55, 65, 75, 85, and 95 degrees Celsius. Oscillation was set at 200 revolutions per minute (rpm) for 15 minutes. The enzyme‐linked immunosorbent assay (ELISA) was applied in measuring the concentration of platelet‐derived growth factor (PDGF) in picogram/milliliter (pg/mL). Repeated measures ANOVA followed by the Bonferroni post hoc test was used to compare the PDGF concentrations between each testing condition. Results. Under 75 degrees Celsius of heating, the resultant paste‐like PRP end product had the highest concentration of PDGF in picograms per milliliter (pg/mL) as compared with other heating conditions (p < 0.05). The viscosity of the paste‐like PRP was measured to be 70,000 centipoise (cP), which is similar to the viscosity of a toothpaste. The paste‐like PRP end product was able to release PDGF continuously for about 14 days, with the highest concentration achieved on the 8th day with an average of 35646 ± 2499 pg/mL. In nonthermally treated liquid‐form PRP sample, the highest number of PRP was observed on the 4th day with an average value of 8444 ± 831 pg/mL. Under the heating conditions of 55 and 95 degrees Celsius, the highest concentration of PDGF was observed on the 5th day (13346 ± 764 pg/mL and 3440 ± 303 pg/mL, respectively). Under the heating conditions of 65 and 85 degrees Celsius, the highest concentration of PDGF was observed on the 7th day (15468 ± 744 pg/mL and 20432 ± 1118 pg/mL, respectively). Conclusion. Through thermal oscillation, liquid‐form PRP can be converted to paste‐like PRP end product with a viscosity similar to that of a toothpaste. The best heating condition was discovered to be 75 degrees Celsius. The paste‐like PRP was able to release PDGF continuously for about 2 weeks, with the highest concentration obtained on the 8th day. The findings in this study suggested that paste‐like PRP may be a viable option in treating degenerative knee joint diseases.
- Open Access
- 28 April 2020
- Published by Springer Nature in Dysphagia
- Vol. 36 (2) , 183-191
Correlation of Temporal Parameters of Laryngeal Excursion by Using Force-Sensing Resistor Sensors with Hyoid Motion in Videofluoroscopic Swallowing Study
Small flexible force-sensing resistor (FSR) sensors can detect laryngeal excursion during swallowing, but the detected laryngeal excursion has not been correlated with videofluoroscopic swallowing study (VFSS) results. Here, we tested the correlation of temporal parameters between the laryngeal excursion recording by FSR sensor and the hyoid motion recording by VFSS under simultaneously swallowing test recordings. Swallowing measurements were recorded in a radiological suite by simultaneously using VFSS and FSR sensors to detect hyoid motion and laryngeal excursion, respectively. Volunteers sat with their head vertical to the Frankfort plane. Two FSR sensors, each for detecting thyroid cartilage excursion and thumb pressing, were placed. VFSS images and FSR sensor signals during single 5-mL barium liquid (30% wt/volume %) bolus swallowing were collected and analyzed for four swallows per participant. In total, 15 men (28.0 ± 4.1 years old); 14 women (28.4 ± 4.2 years old) were recruited. Temporal parameters between VFSS and noninvasive system demonstrated a strong correlation by Pearson’s correlation analysis: in men (R = 0.953–0.999) and in women (R = 0.813–0.982), except for VT1–V1 compared with FT1–F1, which demonstrated a moderate correlation in women (R = 0.648; all p < 0.001). Only VT1–V1 and FT1–F1 in women displayed a significant difference (p = 0.001). Therefore, this is the first study to simultaneous record VFSS and noninvasive signals by FSR sensor. The correlation of temporal parameters between these two tests was strong. This finding is valuable for future applications of this noninvasive swallowing study tool.
- 28 April 2020
- Published by Springer Nature in Dysphagia
- Vol. 36 (2) , 183-191
Open AccessCorrelation of Temporal Parameters of Laryngeal Excursion by Using Force-Sensing Resistor Sensors with Hyoid Motion in Videofluoroscopic Swallowing Study
Small flexible force-sensing resistor (FSR) sensors can detect laryngeal excursion during swallowing, but the detected laryngeal excursion has not been correlated with videofluoroscopic swallowing study (VFSS) results. Here, we tested the correlation of temporal parameters between the laryngeal excursion recording by FSR sensor and the hyoid motion recording by VFSS under simultaneously swallowing test recordings. Swallowing measurements were recorded in a radiological suite by simultaneously using VFSS and FSR sensors to detect hyoid motion and laryngeal excursion, respectively. Volunteers sat with their head vertical to the Frankfort plane. Two FSR sensors, each for detecting thyroid cartilage excursion and thumb pressing, were placed. VFSS images and FSR sensor signals during single 5-mL barium liquid (30% wt/volume %) bolus swallowing were collected and analyzed for four swallows per participant. In total, 15 men (28.0 ± 4.1 years old); 14 women (28.4 ± 4.2 years old) were recruited. Temporal parameters between VFSS and noninvasive system demonstrated a strong correlation by Pearson’s correlation analysis: in men (R = 0.953–0.999) and in women (R = 0.813–0.982), except for VT1–V1 compared with FT1–F1, which demonstrated a moderate correlation in women (R = 0.648; all p < 0.001). Only VT1–V1 and FT1–F1 in women displayed a significant difference (p = 0.001). Therefore, this is the first study to simultaneous record VFSS and noninvasive signals by FSR sensor. The correlation of temporal parameters between these two tests was strong. This finding is valuable for future applications of this noninvasive swallowing study tool.