Branislav Grajciar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Branislav Grajciar has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Adolf F. Fercher
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringerstrasse 13, A-1090 Vienna, Austria
2 shared publications- Rainer Andreas Leitgeb
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
2 shared publications - Cedric Blatter
Center of Biomedical Engineering and Physics, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
1 shared publication - Christoph K. Hitzenberger
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
1 shared publication Martin Gröschl
1 shared publicationMelanie Herdin
1 shared publication
Latest Publications
- 31 December 2011
- Published by Photonics Society of Poland in Photonics Letters of Poland
- Vol. 3 (4)
High-resolution phase mapping with parallel Fourier domain optical coherence microscopy for dispersion contrast imaging
- 31 December 2011
- Published by Photonics Society of Poland in Photonics Letters of Poland
- Vol. 3 (4)
High-resolution phase mapping with parallel Fourier domain optical coherence microscopy for dispersion contrast imaging
- Open Access
- 29 September 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (21) , 21841-21850
High sensitivity phase mapping with parallel Fourier domain optical coherence tomography at 512 000 A-scan/s.
In this paper we present an ultra high speed and highly phase sensitive line-field FD-OCT system for quantitative phase mapping. The system works with a maximum speed of 512 000 A-scan/s (1000 fps) in real time mode. Along the parallel recorded direction excellent phase stability corresponding to a path length variation of only 510 pm was measured. We demonstrate how to exploit this phase accuracy for fast chemical analysis of glucose mixture processes. The system has particular potential for studying micro-fluidic processes.
- 29 September 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (21) , 21841-21850
Open AccessHigh sensitivity phase mapping with parallel Fourier domain optical coherence tomography at 512 000 A-scan/s.
In this paper we present an ultra high speed and highly phase sensitive line-field FD-OCT system for quantitative phase mapping. The system works with a maximum speed of 512 000 A-scan/s (1000 fps) in real time mode. Along the parallel recorded direction excellent phase stability corresponding to a path length variation of only 510 pm was measured. We demonstrate how to exploit this phase accuracy for fast chemical analysis of glucose mixture processes. The system has particular potential for studying micro-fluidic processes.
- 1 January 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (4) , 2405-2414
High sensitive measurement of the human axial eye length in vivo with Fourier domain low coherence interferometry
In this paper we present a system for intraocular distance measurement of the human eye in vivo with high sensitivity. The instrument is based on Fourier domain low coherence interferometry (FD-LCI). Stateof-the-art FD-LCI systems are limited to a depth range of only a few mm, because the depth range is determined by the spectral resolution of the spectrometer. To measure larger distances (e.g. human eye length) we implemented two separate reference arms with different arm lengths into the interferometer. Each reference arm length corresponds to a different depth position within the sample (e.g. cornea and retina). Therefore two different depth sections, each with a depth range of a few mm can be imaged simultaneously. With the new system axial distances could be measured with a precision of 8µm. We demonstrate the performance of the instrument by measuring the axial eye length of 9 patients with cataract and compare our results with those obtained using the IOL Master (Carl Zeiss Meditec Inc.).
- 1 January 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (4) , 2405-2414
High sensitive measurement of the human axial eye length in vivo with Fourier domain low coherence interferometry
In this paper we present a system for intraocular distance measurement of the human eye in vivo with high sensitivity. The instrument is based on Fourier domain low coherence interferometry (FD-LCI). Stateof-the-art FD-LCI systems are limited to a depth range of only a few mm, because the depth range is determined by the spectral resolution of the spectrometer. To measure larger distances (e.g. human eye length) we implemented two separate reference arms with different arm lengths into the interferometer. Each reference arm length corresponds to a different depth position within the sample (e.g. cornea and retina). Therefore two different depth sections, each with a depth range of a few mm can be imaged simultaneously. With the new system axial distances could be measured with a precision of 8µm. We demonstrate the performance of the instrument by measuring the axial eye length of 9 patients with cataract and compare our results with those obtained using the IOL Master (Carl Zeiss Meditec Inc.).
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 47-50
Full Field Fourier Domain Optical Coherence Tomography
Optical coherence tomography (OCT) is a non-invasive interferometric imaging technique offering millimeter penetration depths of a sample with outstanding axial resolution. In this work a parallel Fourier domain optical coherence tomography (FD OCT) system is presented which records full tomograms of the sample structure in parallel. A fully parallel FD OCT system allows fast real time imaging of biological tissues.
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 47-50
Full Field Fourier Domain Optical Coherence Tomography
Optical coherence tomography (OCT) is a non-invasive interferometric imaging technique offering millimeter penetration depths of a sample with outstanding axial resolution. In this work a parallel Fourier domain optical coherence tomography (FD OCT) system is presented which records full tomograms of the sample structure in parallel. A fully parallel FD OCT system allows fast real time imaging of biological tissues.