Qijun Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qijun Su has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Fu
School of Automation, Qingdao University, Qingdao 266071, China
2 shared publications - Chenghui Zhang
Shandong University
2 shared publications - Guanguan Zhang
School of Control Science and Engineering, Shandong University, Jinan 250061, China
2 shared publications - Chen Zhang
School of Control Science and Engineering, Shandong University, Jinan, China
1 shared publication
Latest Publications
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 70 (8) , 3044-3048
Finite-Time Adaptive Fuzzy Control for Three-Phase PWM Rectifiers With Improved Output Performance
For three-phase pulse width modulation (PWM) rectifiers, system uncertainties, such as load disturbances, parametric uncertainties, and grid disturbances, may result in significant DC-link voltage fluctuations, degrade the quality of grid currents, and even lead to system instability. To address this issue, a modified dynamic model of the PWM rectifier with system uncertainties is established, and a finite-time adaptive fuzzy control (FTAFC) method with the dual-loop structure is proposed. In the outer voltage loop, a finite-time adaptive law is used to maintain stable DC-link voltages despite load disturbances. In the inner power loop, an adaptive fuzzy technique is used to estimate and compensate system uncertainties, thus ensuring finite-time power tracking. It is confirmed that all signals of the closed-loop system are finite-time bounded. The experimental and simulation results demonstrate the effectiveness of the proposed method.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 70 (8) , 3044-3048
Finite-Time Adaptive Fuzzy Control for Three-Phase PWM Rectifiers With Improved Output Performance
For three-phase pulse width modulation (PWM) rectifiers, system uncertainties, such as load disturbances, parametric uncertainties, and grid disturbances, may result in significant DC-link voltage fluctuations, degrade the quality of grid currents, and even lead to system instability. To address this issue, a modified dynamic model of the PWM rectifier with system uncertainties is established, and a finite-time adaptive fuzzy control (FTAFC) method with the dual-loop structure is proposed. In the outer voltage loop, a finite-time adaptive law is used to maintain stable DC-link voltages despite load disturbances. In the inner power loop, an adaptive fuzzy technique is used to estimate and compensate system uncertainties, thus ensuring finite-time power tracking. It is confirmed that all signals of the closed-loop system are finite-time bounded. The experimental and simulation results demonstrate the effectiveness of the proposed method.
- 13 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (7) , 6876-6886
Finite-Time Command Filtered Control of Three-Phase AC/DC Converter Under Unbalanced Grid Conditions
For the three-phase ac/dc converter, unbalanced grid voltages cause grid current distortions and dc-link voltage fluctuations, threatening the safe operation of the power grid or loads. To address this issue, the control targets of the ac/dc converter under unbalanced grids are transformed into a unified power tracking problem by introducing modified power references. Then, the finite-time command filtered control (FTCFC) of the ac/dc converter is proposed, and the dual-loop control structure of inner power and outer dc-link voltage is studied, where the active and reactive powers are independently regulated without the current control loop and the phase-locked loop. In this method, the proposed command filter estimates the power references' derivatives, and the fixed-time disturbance observer is designed to suppress the unknown load disturbances on the dc-link voltage control loop. Theoretical analysis and experimental results validate the effectiveness of the proposed FTCFC method, and the fast and accurate power tracking performance is achieved for all three control modes. Compared with the PI+backstepping control, the FTCFC method improves the tracking performance of the dc-link voltage and powers and reduces the current THD by 35.2%.
- 13 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (7) , 6876-6886
Finite-Time Command Filtered Control of Three-Phase AC/DC Converter Under Unbalanced Grid Conditions
For the three-phase ac/dc converter, unbalanced grid voltages cause grid current distortions and dc-link voltage fluctuations, threatening the safe operation of the power grid or loads. To address this issue, the control targets of the ac/dc converter under unbalanced grids are transformed into a unified power tracking problem by introducing modified power references. Then, the finite-time command filtered control (FTCFC) of the ac/dc converter is proposed, and the dual-loop control structure of inner power and outer dc-link voltage is studied, where the active and reactive powers are independently regulated without the current control loop and the phase-locked loop. In this method, the proposed command filter estimates the power references' derivatives, and the fixed-time disturbance observer is designed to suppress the unknown load disturbances on the dc-link voltage control loop. Theoretical analysis and experimental results validate the effectiveness of the proposed FTCFC method, and the fast and accurate power tracking performance is achieved for all three control modes. Compared with the PI+backstepping control, the FTCFC method improves the tracking performance of the dc-link voltage and powers and reduces the current THD by 35.2%.