Patrick Gathogo Home
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Patrick Gathogo Home has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- James Messo Raude
Soil, Water and Environmental Engineering Department, Jomo Kenyatta University of Agriculture and Technology, P.O. Box 62000-00200, Nairobi, Kenya
3 shared publications - Moise Ndekezi
Department of Civil Engineering, Pan African University's Institute for Basic Sciences, Technology and Innovation (PAUSTI), P. O. Box 62000-00200, Nairobi, Kenya
2 shared publications Abigail Chepkemoi Kenduiywo
1 shared publication- Austine Otieno
Department of Geoscience and the Environment (DGSE), Technical University of Kenya, P.O. Box 52428-00200, Nairobi, Kenya
1 shared publication - Faith Chepkwony
Soil, Water and Environmental Engineering Department (SWEED), Jomo Kenyatta University of Agriculture and Technology, P.O. Box 62000-00200, Nairobi, Kenya
1 shared publication - Hannah Mbogo
Department of Soil, Water and Environmental Engineering, Jomo Kenyatta University of Agriculture and Technology, P.O. Box 62 000–00200, Nairobi, Kenya
1 shared publication
Latest Publications
- 1 September 2026
- Published by IWA Publishing in Water Practice & Technology
- Vol. 21 (9) , 4551-4569
Pollutant removal efficiency and reliability of sand dams as a sustainable in situ rainwater harvesting option in dryland environments: a case study from South-Eastern Kenya's drylands
The graphical abstract illustrates groundwater system fluxes in a sand dam, an in-situ rainwater harvesting system, showing key inflows (recharge from surface runoff) and outflows (evaporation, seepage, water abstraction) and major water uses. Water quality is assessed by comparing influent and effluent concentrations to determine pollutant removal efficiency. Positive removal efficiencies were observed for turbidity, TSS, dissolved oxygen, BOD, COD, ammonia, phosphates, iron, and copper, whereas negative removal efficiencies occurred for electrical conductivity, TDS, total hardness, fluoride, sulphates, nitrates, magnesium, zinc, chromium, and total coliforms. Overall, sand dams demonstrated high effectiveness in removing turbidity-related pollutants but limited reliability for salts, metals, and microorganisms. Drylands sustain billions of people and ecosystems. In Kenya, drylands cover 89% of the country, home to 36% of the population, 70% of the livestock and 90% of the wildlife. These groups are particularly vulnerable to water scarcity, mitigated through sand dams, an in situ rainwater harvesting technology. These function as natural slow sand filters to provide drinking water; yet, their filtration performance remains understudied. This study therefore examined their filtration capacity. Three sand dams were purposively selected and equipped with temporary sand-point wells to sample outflow, while stormwater inflow was sampled to assess removal efficiencies of 23 water quality parameters. A one-sample two-tailed t-test was used to evaluate whether the mean removal efficiency differed significantly from the assumed value. Results showed that 9 of the 22 parameters differed significantly from the hypothesized value of 60% (p < 0.05), whereas 13 did not (p ≥ 0.05). Sand dams effectively reduced suspended solids (85.68%), turbidity (86.94%) and iron (72.2%) but exhibited negative removal efficiencies for microorganisms and metals. Negative efficiencies may reflect environmental and operational complexities rather than treatment system failure. Therefore, water collected from sand dams for drinking should undergo household treatment such as boiling, chlorination or solar disinfection before consumption.
- 1 September 2026
- Published by IWA Publishing in Water Practice & Technology
- Vol. 21 (9) , 4551-4569
Pollutant removal efficiency and reliability of sand dams as a sustainable in situ rainwater harvesting option in dryland environments: a case study from South-Eastern Kenya's drylands
The graphical abstract illustrates groundwater system fluxes in a sand dam, an in-situ rainwater harvesting system, showing key inflows (recharge from surface runoff) and outflows (evaporation, seepage, water abstraction) and major water uses. Water quality is assessed by comparing influent and effluent concentrations to determine pollutant removal efficiency. Positive removal efficiencies were observed for turbidity, TSS, dissolved oxygen, BOD, COD, ammonia, phosphates, iron, and copper, whereas negative removal efficiencies occurred for electrical conductivity, TDS, total hardness, fluoride, sulphates, nitrates, magnesium, zinc, chromium, and total coliforms. Overall, sand dams demonstrated high effectiveness in removing turbidity-related pollutants but limited reliability for salts, metals, and microorganisms. Drylands sustain billions of people and ecosystems. In Kenya, drylands cover 89% of the country, home to 36% of the population, 70% of the livestock and 90% of the wildlife. These groups are particularly vulnerable to water scarcity, mitigated through sand dams, an in situ rainwater harvesting technology. These function as natural slow sand filters to provide drinking water; yet, their filtration performance remains understudied. This study therefore examined their filtration capacity. Three sand dams were purposively selected and equipped with temporary sand-point wells to sample outflow, while stormwater inflow was sampled to assess removal efficiencies of 23 water quality parameters. A one-sample two-tailed t-test was used to evaluate whether the mean removal efficiency differed significantly from the assumed value. Results showed that 9 of the 22 parameters differed significantly from the hypothesized value of 60% (p < 0.05), whereas 13 did not (p ≥ 0.05). Sand dams effectively reduced suspended solids (85.68%), turbidity (86.94%) and iron (72.2%) but exhibited negative removal efficiencies for microorganisms and metals. Negative efficiencies may reflect environmental and operational complexities rather than treatment system failure. Therefore, water collected from sand dams for drinking should undergo household treatment such as boiling, chlorination or solar disinfection before consumption.
- 1 September 2026
- Published by IWA Publishing in Journal of Water, Sanitation and Hygiene for Development
- Vol. 16 (9) , 807-826
A comparative quantitative microbial risk assessment of fecal sludge management systems: A case study of Mukuru Kwa Njenga Slum in Kenya
Pictorial presentation of the research paper. Safely managed sanitation systems should protect humans from fecal contamination through every possible exposure pathway. However, different fecal sludge management (FSM) systems pose varying health risks along the service chain. This study applied quantitative microbial risk assessment to estimate health risks posed by eight FSM systems in Kenya's Mukuru Kwa Njenga Slum. Based on four reference pathogens: Vibrio cholerae, Rotavirus, Cryptosporidium spp., and Ascaris lumbricoides, the study considered maximally exposed users, workers, and residents, through ingestion from hands, water, soil, and vegetables. It aimed at aiding targeted mitigation measures. Open defecation posed the highest estimated daily probability of infection (93%), followed by manual pit emptying at 88%. The closed waterless pit system posed the lowest average risk of infection at 10% compared with the manually emptied systems and the water-based systems. This was due to increased exposure pathways and subsequent downstream contamination, respectively. V. cholerae was the most prevalent pathogen, posing an estimated disease burden of 4.27 × 10−1 disability adjusted life years per person per year, due to high case fatality rates. Therefore, health risk mitigation strategies such as effective use of personal protective equipment should target specific exposed population including cleaners, pit emptiers, and treatment workers.
- 1 September 2026
- Published by IWA Publishing in Journal of Water, Sanitation and Hygiene for Development
- Vol. 16 (9) , 807-826
A comparative quantitative microbial risk assessment of fecal sludge management systems: A case study of Mukuru Kwa Njenga Slum in Kenya
Pictorial presentation of the research paper. Safely managed sanitation systems should protect humans from fecal contamination through every possible exposure pathway. However, different fecal sludge management (FSM) systems pose varying health risks along the service chain. This study applied quantitative microbial risk assessment to estimate health risks posed by eight FSM systems in Kenya's Mukuru Kwa Njenga Slum. Based on four reference pathogens: Vibrio cholerae, Rotavirus, Cryptosporidium spp., and Ascaris lumbricoides, the study considered maximally exposed users, workers, and residents, through ingestion from hands, water, soil, and vegetables. It aimed at aiding targeted mitigation measures. Open defecation posed the highest estimated daily probability of infection (93%), followed by manual pit emptying at 88%. The closed waterless pit system posed the lowest average risk of infection at 10% compared with the manually emptied systems and the water-based systems. This was due to increased exposure pathways and subsequent downstream contamination, respectively. V. cholerae was the most prevalent pathogen, posing an estimated disease burden of 4.27 × 10−1 disability adjusted life years per person per year, due to high case fatality rates. Therefore, health risk mitigation strategies such as effective use of personal protective equipment should target specific exposed population including cleaners, pit emptiers, and treatment workers.
- Open Access
- 5 December 2025
- Published by IWA Publishing in Water Science & Technology
- Vol. 92 (12) , 1727-1750
Performance evaluation of lateritic soil and fungi ( Agaricus impudicus ) in the adsorption and desorption of ammonium nitrogen from human urine
The recovery of ammonium nitrogen (NH4+-N) from human urine offers a sustainable strategy to mitigate eutrophication and enhance nutrient recovery for agricultural use. Despite numerous adsorbents being explored, low-cost and eco-friendly options remain limited, prompting investigation into locally available lateritic soils (LS) and the fungus Agaricus impudicus as alternative materials. This study evaluated the potential of LS and fungal biomass as adsorbents for NH4+-N recovering from human urine. The materials were characterized using FTIR, SEM, and elemental analysis to determine surface functional groups and morphological features relevant to adsorption. Batch experiments were conducted to assess the adsorption capacity and desorption properties of the adsorbents. The equilibrium data were analyzed using Dubinin–Radushkevich (D-R), Freundlich, and Langmuir isotherm models to determine the adsorption mechanisms and capacities. The D-R model best described NH4+-N adsorption on LS (R2 = 0.968), indicating a predominantly physical adsorption process, while the Freundlich model best fitted the fungal biomass data (R2 = 0.813), suggesting multilayer adsorption on heterogeneous surfaces. LS exhibited a higher adsorption capacity (16.314 mg/g) than fungal biomass, which could be attributed to its mineralogical composition. Overall, both adsorbents demonstrated effective NH4+-N removal and moderate nutrient release, highlighting their potential for sustainable nutrient recovery and reuse in agriculture.
- 5 December 2025
- Published by IWA Publishing in Water Science & Technology
- Vol. 92 (12) , 1727-1750
Open AccessPerformance evaluation of lateritic soil and fungi ( Agaricus impudicus ) in the adsorption and desorption of ammonium nitrogen from human urine
The recovery of ammonium nitrogen (NH4+-N) from human urine offers a sustainable strategy to mitigate eutrophication and enhance nutrient recovery for agricultural use. Despite numerous adsorbents being explored, low-cost and eco-friendly options remain limited, prompting investigation into locally available lateritic soils (LS) and the fungus Agaricus impudicus as alternative materials. This study evaluated the potential of LS and fungal biomass as adsorbents for NH4+-N recovering from human urine. The materials were characterized using FTIR, SEM, and elemental analysis to determine surface functional groups and morphological features relevant to adsorption. Batch experiments were conducted to assess the adsorption capacity and desorption properties of the adsorbents. The equilibrium data were analyzed using Dubinin–Radushkevich (D-R), Freundlich, and Langmuir isotherm models to determine the adsorption mechanisms and capacities. The D-R model best described NH4+-N adsorption on LS (R2 = 0.968), indicating a predominantly physical adsorption process, while the Freundlich model best fitted the fungal biomass data (R2 = 0.813), suggesting multilayer adsorption on heterogeneous surfaces. LS exhibited a higher adsorption capacity (16.314 mg/g) than fungal biomass, which could be attributed to its mineralogical composition. Overall, both adsorbents demonstrated effective NH4+-N removal and moderate nutrient release, highlighting their potential for sustainable nutrient recovery and reuse in agriculture.
- Open Access
- 16 May 2023
- Published by African Journals Online (AJOL) in Journal of Agriculture, Science and Technology
- Vol. 22 (3) , 116-135
Aquifer characterization using geophysical and pumping test data in Kericho, Kenya
The exploration of groundwater resources has considerable potential for boosting water supplies in Kericho County, Kenya. However, it is underused due to limited knowledge caused by lack of adequate research in this field. As a way to fill this gap, this study aimed to characterize hydraulic and hydrogeological parameters controlling groundwater occurrence in the Kericho aquifer in Kericho County, Kenya. To achieve this objective, the study utilized a combination of geophysical and pumping test data. Consequently, fifty Vertical Electric Soundings (VES) were carried out to determine the aquifer properties of the study area. Further, seven out of fifty surveyed sites were drilled to depths ranging between 30m and 230m, and test pumping was done for 24 hours. Geophysical results show that the average hydraulic conductivity in the study area varies from 1.96 m day-1 to 6.2 m day-1 . The transmissivity ranged from 35.83 m2 day-1 to 5166.4 m2 day-1 , while the yield ranged between 0.7 and 9.7 M3 /hr. The aquifer hydraulic parameters determined from geophysical and pumping test data were analysed using one-way analysis of variance (ANOVA). The results show no significant difference (p = 0.948151> 0.05) on hydraulic conductivity between geophysical and pumping test methods. Therefore, this study confirmed the reliability of both methodologies for groundwater assessment. Identifying prospective groundwater zones in the research area demonstrates that the combination of these methods is efficient and suited for groundwater exploration. It is suggested that observation wells be added in future studies to allow for the computation of storativity.
- 16 May 2023
- Published by African Journals Online (AJOL) in Journal of Agriculture, Science and Technology
- Vol. 22 (3) , 116-135
Open AccessAquifer characterization using geophysical and pumping test data in Kericho, Kenya
The exploration of groundwater resources has considerable potential for boosting water supplies in Kericho County, Kenya. However, it is underused due to limited knowledge caused by lack of adequate research in this field. As a way to fill this gap, this study aimed to characterize hydraulic and hydrogeological parameters controlling groundwater occurrence in the Kericho aquifer in Kericho County, Kenya. To achieve this objective, the study utilized a combination of geophysical and pumping test data. Consequently, fifty Vertical Electric Soundings (VES) were carried out to determine the aquifer properties of the study area. Further, seven out of fifty surveyed sites were drilled to depths ranging between 30m and 230m, and test pumping was done for 24 hours. Geophysical results show that the average hydraulic conductivity in the study area varies from 1.96 m day-1 to 6.2 m day-1 . The transmissivity ranged from 35.83 m2 day-1 to 5166.4 m2 day-1 , while the yield ranged between 0.7 and 9.7 M3 /hr. The aquifer hydraulic parameters determined from geophysical and pumping test data were analysed using one-way analysis of variance (ANOVA). The results show no significant difference (p = 0.948151> 0.05) on hydraulic conductivity between geophysical and pumping test methods. Therefore, this study confirmed the reliability of both methodologies for groundwater assessment. Identifying prospective groundwater zones in the research area demonstrates that the combination of these methods is efficient and suited for groundwater exploration. It is suggested that observation wells be added in future studies to allow for the computation of storativity.
- Open Access
- 14 January 2023
- Published by Taylor & Francis in Cogent Engineering
- Vol. 10 (1)
Performance evaluation of sand dams as a rural rainwater conservation and domestic water supply technology in East-African drylands, a case-study from South-Eastern Kenya
Sand dams (SDs) are rainwater harvesting methods in East-African drylands for rural water supplies and small-scale irrigation practices. However, little information exists on their ability to maintain the harvested water in the right quantity and quality. Three SDs were selected from south-eastern Kenya’s semi-arid zone as a case study to evaluate their operational performance. Water and sediment samples were collected and analyzed in both the field and laboratory. Six performance indicators, namely stormwater-capture efficiency (SCE), water-saving efficiency (WSE), volume-based and time-based reliabilities, water demand satisfaction rate (WDSR), water loss percentage, physicochemical water pollution index (WPI) and microbial non-compliance rate (NCR), were computed. Results showed that water storage in SDs is quite low and unfit for direct human consumption. In fact, three experimental SDs harvested 7,356 m3 during the long-rains season (March–May 2018) for an estimated water demand of 8,990 m3 (June–September). About 4,505 m3 (61.24%) was lost through evaporation (64.11%) and seepage (35.89%). These SDs exhibited low WDSR (31.72%), inadequate SCE (3.09%), low WSE (30.85%), dismal volume reliability (24.56%), and undependable time reliability (24.91%). Shallow-well water was less polluted than scoop-hole water but both didn’t meet the bacterial water quality standard (0 CFU/100 mL). The former scored a low WPI of 1.86 (reasonably clean) compared to clean water (WPI ≤ 1), while the latter scored a high WPI of 12.91 (considerably polluted). Furthermore, NCRs for total coliforms were 60% in shallow wells and 90.79% in scoop holes. Therefore, this water should be treated and disinfected for domestic use.
- 14 January 2023
- Published by Taylor & Francis in Cogent Engineering
- Vol. 10 (1)
Open AccessPerformance evaluation of sand dams as a rural rainwater conservation and domestic water supply technology in East-African drylands, a case-study from South-Eastern Kenya
Sand dams (SDs) are rainwater harvesting methods in East-African drylands for rural water supplies and small-scale irrigation practices. However, little information exists on their ability to maintain the harvested water in the right quantity and quality. Three SDs were selected from south-eastern Kenya’s semi-arid zone as a case study to evaluate their operational performance. Water and sediment samples were collected and analyzed in both the field and laboratory. Six performance indicators, namely stormwater-capture efficiency (SCE), water-saving efficiency (WSE), volume-based and time-based reliabilities, water demand satisfaction rate (WDSR), water loss percentage, physicochemical water pollution index (WPI) and microbial non-compliance rate (NCR), were computed. Results showed that water storage in SDs is quite low and unfit for direct human consumption. In fact, three experimental SDs harvested 7,356 m3 during the long-rains season (March–May 2018) for an estimated water demand of 8,990 m3 (June–September). About 4,505 m3 (61.24%) was lost through evaporation (64.11%) and seepage (35.89%). These SDs exhibited low WDSR (31.72%), inadequate SCE (3.09%), low WSE (30.85%), dismal volume reliability (24.56%), and undependable time reliability (24.91%). Shallow-well water was less polluted than scoop-hole water but both didn’t meet the bacterial water quality standard (0 CFU/100 mL). The former scored a low WPI of 1.86 (reasonably clean) compared to clean water (WPI ≤ 1), while the latter scored a high WPI of 12.91 (considerably polluted). Furthermore, NCRs for total coliforms were 60% in shallow wells and 90.79% in scoop holes. Therefore, this water should be treated and disinfected for domestic use.