Yulin Kuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yulin Kuang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Fujun Ma
College of Electrical and Information Engineering, Hunan University, Changsha, China
2 shared publications Cheng Yang
College of Electrical and Information Engineering, Hunan University, Changsha, Hunan, CHINA
1 shared publication- Cheng Zhang
College of Electrical and Information Engineering, Hunan University, Changsha 410000, China
1 shared publication - Dexing Kuang
College of Electrical and Information Engineering, Hunan University, Changsha 410000, China
1 shared publication - Gelin Huang
College of Electrical and Information Engineering, Hunan University, Changsha 410000, China
1 shared publication - Gelin Huang
College of Electrical and Information Engineering, Hunan University, Changsha, China
1 shared publication
Latest Publications
- Open Access
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135854-135863
Pre-Synchronization Control Strategy for Virtual Synchronous Generator Grid Connection Based on Voltage Mathematical Relationships
Conventional pre-synchronization control strategies for grid-connected virtual synchronous generator typically involve phase-locked loops, coordinate transformations or other non-linear computations, which may lead to substantial hardware resource consumption, pre-synchronization failures, even potential system instability. Hence, the mathematical relationships between voltage differences and angle differences on both sides before grid-connecting are analyzed. Based on those relationships, A pre-synchronization control strategy is proposed. It achieves smooth grid connection only by simple linear calculations using the filter capacitor voltage and the grid voltage. The difference between the effective values of these two voltage components is processed through a PI controller, with the result serving as a correction value for the output voltage command of the reactive power loop. The instantaneous value difference of the corresponding phase voltages is summed in absolute terms and processed through another PI controller, with the resulting output serving as a correction value for the frequency command of the active power loop. The cutoff frequencies of the two PI controllers are staggered to achieve decoupling. Control parameters are designed through stability analysis. Finally, experimental results validate the effectiveness of the proposed control strategy.
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135854-135863
Open AccessPre-Synchronization Control Strategy for Virtual Synchronous Generator Grid Connection Based on Voltage Mathematical Relationships
Conventional pre-synchronization control strategies for grid-connected virtual synchronous generator typically involve phase-locked loops, coordinate transformations or other non-linear computations, which may lead to substantial hardware resource consumption, pre-synchronization failures, even potential system instability. Hence, the mathematical relationships between voltage differences and angle differences on both sides before grid-connecting are analyzed. Based on those relationships, A pre-synchronization control strategy is proposed. It achieves smooth grid connection only by simple linear calculations using the filter capacitor voltage and the grid voltage. The difference between the effective values of these two voltage components is processed through a PI controller, with the result serving as a correction value for the output voltage command of the reactive power loop. The instantaneous value difference of the corresponding phase voltages is summed in absolute terms and processed through another PI controller, with the resulting output serving as a correction value for the frequency command of the active power loop. The cutoff frequencies of the two PI controllers are staggered to achieve decoupling. Control parameters are designed through stability analysis. Finally, experimental results validate the effectiveness of the proposed control strategy.
- 24 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Vol. 13 (2) , 524-535
A Current-Limiting Scheme for Voltage-Controlled Inverter Using Instantaneous Current to Generate Virtual Impedance
In this paper, a current-limiting scheme is proposed for the voltage-controlled inverter. The method utilizes instantaneous current to quickly activate a resistive fault-current-limiting virtual impedance (R FCL ) to suppress the instantaneous impulse current and steady-state overload current, which can be directly integrated into the existing voltage-type control scheme. When a fault occurs, the inverter can be kept in the voltage control mode without mode switching. After the fault is cleared, it can automatically return to the normal operation mode. The parameter selection method of the current-limiting virtual impedance is analyzed, and the logic criterion for short-circuit fault clearance is presented to realize the automatic startup and exit of the current-limiting virtual impedance. Finally, the RT-LAB hardware in-loop experiment and the single-phase inverter platform experiment prove that the proposed current-limiting scheme can simplify the fault handling process and improve the anti-fault ability of the voltage-controlled inverter.
- 24 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Vol. 13 (2) , 524-535
A Current-Limiting Scheme for Voltage-Controlled Inverter Using Instantaneous Current to Generate Virtual Impedance
In this paper, a current-limiting scheme is proposed for the voltage-controlled inverter. The method utilizes instantaneous current to quickly activate a resistive fault-current-limiting virtual impedance (R FCL ) to suppress the instantaneous impulse current and steady-state overload current, which can be directly integrated into the existing voltage-type control scheme. When a fault occurs, the inverter can be kept in the voltage control mode without mode switching. After the fault is cleared, it can automatically return to the normal operation mode. The parameter selection method of the current-limiting virtual impedance is analyzed, and the logic criterion for short-circuit fault clearance is presented to realize the automatic startup and exit of the current-limiting virtual impedance. Finally, the RT-LAB hardware in-loop experiment and the single-phase inverter platform experiment prove that the proposed current-limiting scheme can simplify the fault handling process and improve the anti-fault ability of the voltage-controlled inverter.
- Open Access
Multi-Port and -Functional Power Conditioner and Its Control Strategy with Renewable Energy Access for a Railway Traction System
To relieve the contradiction between supply and demand, a multi-port power conditioner (MP-PC) and control strategy with renewable energy access for a railway traction system is presented, which is mainly composed of full-bridge-based MMC and isolated DC/DC converters. As for the full-bridge-based MMC, the equivalent model is established and its novel voltage control method is proposed, which can provide a medium/low-voltage DC-link. A renewable energy system is connected to the system through the DC-link, so the MP-PC can achieve on-site consumption and balance between the load power and output power of RESs. Meanwhile, with the proposed control strategy, MP-PC can achieve three-phase power balance control and improve the operation performance of the railway traction system. Finally, the traction power platform and simulation model are established in the lab, and the topology and control strategy of MP-PC are verified effectively.
Open AccessMulti-Port and -Functional Power Conditioner and Its Control Strategy with Renewable Energy Access for a Railway Traction System
To relieve the contradiction between supply and demand, a multi-port power conditioner (MP-PC) and control strategy with renewable energy access for a railway traction system is presented, which is mainly composed of full-bridge-based MMC and isolated DC/DC converters. As for the full-bridge-based MMC, the equivalent model is established and its novel voltage control method is proposed, which can provide a medium/low-voltage DC-link. A renewable energy system is connected to the system through the DC-link, so the MP-PC can achieve on-site consumption and balance between the load power and output power of RESs. Meanwhile, with the proposed control strategy, MP-PC can achieve three-phase power balance control and improve the operation performance of the railway traction system. Finally, the traction power platform and simulation model are established in the lab, and the topology and control strategy of MP-PC are verified effectively.