Latest Publications

  • Open Access

    A Lumped-Parameter Model of the Cardiovascular System Response for Evaluating Automated Fluid Resuscitation Systems

    by Yekanth Ram Chalumuri, Ghazal Arabidarrehdor, Ali Tivay, Catherine M. Sampson, Muzna Khan, Michael Kinsky, George C. Kramer, Jin-Oh Hahn, Christopher G. Scully, Ramin Bighamian

    Physiological closed-loop controlled (PCLC) medical devices, such as those designed for blood pressure regulation, can be tested for safety and efficacy in real-world clinical settings. However, relying solely on limited animal and clinical studies may not capture the diverse range of physiological conditions. Credible mathematical models can complement these studies by allowing the testing of the device against simulated patient scenarios. This research involves the development and validation of a low-order lumped-parameter mathematical model of the cardiovascular system’s response to fluid perturbation. The model takes rates of hemorrhage and fluid infusion as inputs and provides hematocrit and blood volume, heart rate, stroke volume, cardiac output and mean arterial blood pressure as outputs. The model was calibrated using data from 27 sheep subjects, and its predictive capability was evaluated through a leave-one-out cross-validation procedure, followed by independent validation using 12 swine subjects. Our findings showed small model calibration error against the training dataset, with the normalized root-mean-square error (NRMSE) less than 10% across all variables. The mathematical model and virtual patient cohort generation tool demonstrated a high level of predictive capability and successfully generated a sufficient number of subjects that closely resembled the test dataset. The average NRMSE for the best virtual subject, across two distinct samples of virtual subjects, was below 12.7% and 11.9% for the leave-one-out cross-validation and independent validation dataset. These findings suggest that the model and virtual cohort generator are suitable for simulating patient populations under fluid perturbation, indicating their potential value in PCLC medical device evaluation.


  • A Mathematical Model for Simulation of Vasoplegic Shock and Vasopressor Therapy

    by Yi-Ming Kao, Catherine M. Sampson, Syed A. Shah, John R. Salsbury, Ali Tivay, Ramin Bighamian, Christopher G. Scully, Michael Kinsky, George C. Kramer, Jin-Oh Hahn

    Objective : To develop a high-fidelity mathematical model intended to replicate the cardiovascular (CV) responses of a critically ill patient to vasoplegic shock-induced hypotension and vasopressor therapy. Methods: The mathematical model consists of a lumped-parameter CV physiology model with baroreflex modulation feedback and a phenomenological dynamic dose-response model of a vasopressor. The adequacy of the proposed mathematical model was investigated using an experimental dataset acquired from 10 pigs receiving phenylephrine (PHP) therapy after vasoplegic shock induced via sodium nitroprusside (SNP). Results: Upon calibration, the mathematical model could (i) faithfully replicate the effects of PHP on dynamic changes in blood pressure (BP), cardiac output (CO), and systemic vascular resistance (SVR) (root-mean-squared errors between measured and calibrated mathematical responses: mean arterial BP 2.5+/-1.0 mmHg, CO 0.2+/-0.1 lpm, SVR 2.4+/-1.5 mmHg/lpm; r value: mean arterial BP 0.96+/-0.01, CO 0.65+/-0.45, TPR 0.92+/-0.10) and (ii) predict physiologically plausible behaviors of unmeasured internal CV variables as well as secondary baroreflex modulation effects. Conclusion: This mathematical model is perhaps the first of its kind that can comprehensively replicate both primary (i.e., direct) and secondary (i.e., baroreflex modulation) effects of a vasopressor drug on an array of CV variables, rendering it ideally suited to pre-clinical virtual evaluation of the safety and efficacy of closed-loop control algorithms for autonomous vasopressor administration once it is extensively validated. Significance: This mathematical model architecture incorporating both direct and baroreflex modulation effects may generalize to serve as part of an effective platform for high-fidelity in silico simulation of CV responses to vasopressors during vasoplegic shock.


  • Assessing Decreased Thoracic Compliance With Forced Oscillation Technique and Spirometry

    by Muzna N Khan, José D Rojas, Richard D Branson, Syed A Shah, Catherine M Sampson, Roger Seeton, Dario Rodriquez, Michael P Kinsky