Tim Rese
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tim Rese has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Isabell Schulz
Institute of Computer-assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité, Augustenburger Platz 1, 13353 Berlin, Germany; Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt - Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
4 shared publications - Michael Lommel
Institute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charit, CharitUniversittsmedizin Berlin, Berlin, Germany
4 shared publications - Ulrich Kertzscher
Institute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charit, CharitUniversittsmedizin Berlin, Berlin, Germany
4 shared publications - Christian Oliver Paschereit
TU Berlin
2 shared publications - Felix Hehnen
Deutsches Herzzentrum der Charité, Institute of Computer-Assisted Cardiovascular Medicine, Augustenburger Platz 1, 13353 Berlin, Germany
2 shared publications - Stefan Moritz
Section of Clinical Infectious Diseases, University Hospital Halle, Halle, Germany
2 shared publications
Latest Publications
- Open Access
- 2 November 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 164, 106206
A novel measurement method to estimate the risk of transmitting airborne diseases during dental treatments
- 2 November 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 164, 106206
Open AccessA novel measurement method to estimate the risk of transmitting airborne diseases during dental treatments
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 306-310
A Passive Heart Mock-Loop with an Unpunctured Natural Heart to Enable Cardiac Device Testing
This paper presents the design and functional evaluation of a novel pulsatile mock-loop system designed to accommodate whole natural heart samples of various sizes, replicating both systemic and pulmonary circulation. Unlike existing models in the literature, this mock-loop uses an external pressurisation principle that preserves the integrity of native atrial and ventricular tissue, eliminating the need for penetration or damage during the experimental process. The flow and pressure profiles indicate a moderate functionality of the heart. Comparative analysis with other mock-loop designs highlights the advantages of this approach in maintaining tissue viability and providing a more realistic simulation of the natural environment of the heart.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 306-310
A Passive Heart Mock-Loop with an Unpunctured Natural Heart to Enable Cardiac Device Testing
This paper presents the design and functional evaluation of a novel pulsatile mock-loop system designed to accommodate whole natural heart samples of various sizes, replicating both systemic and pulmonary circulation. Unlike existing models in the literature, this mock-loop uses an external pressurisation principle that preserves the integrity of native atrial and ventricular tissue, eliminating the need for penetration or damage during the experimental process. The flow and pressure profiles indicate a moderate functionality of the heart. Comparative analysis with other mock-loop designs highlights the advantages of this approach in maintaining tissue viability and providing a more realistic simulation of the natural environment of the heart.
- Open Access
- 27 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5601
Experimental Device to Evaluate Aerosol Dispersion in Venues
The COVID-19 pandemic has focused attention on the importance of understanding and mitigating the airborne transmission of pathogens in indoor environments. This study investigated the aerosol distribution in different indoor venues with varying ventilation concepts, including displacement, mixed, and natural ventilation. A measurement system was developed to investigate venue-specific aerosol distribution patterns using a sodium chloride solution as a tracer. To analyse the spatial dispersion of aerosols, Computational Fluid Dynamics (CFD) simulations were conducted in addition to experimental investigations. The investigations indicated the lowest aerosol load for the venue with displacement ventilation and the highest for the naturally ventilated venue. The measurement system developed in this study provides a useful tool for assessing the effectiveness of ventilation measures in reducing airborne transmission of pathogens in indoor environments. It also proved its wide range of applications, as it can be used in variously sized and shaped indoor environments, with or without an audience.
- 27 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5601
Open AccessExperimental Device to Evaluate Aerosol Dispersion in Venues
The COVID-19 pandemic has focused attention on the importance of understanding and mitigating the airborne transmission of pathogens in indoor environments. This study investigated the aerosol distribution in different indoor venues with varying ventilation concepts, including displacement, mixed, and natural ventilation. A measurement system was developed to investigate venue-specific aerosol distribution patterns using a sodium chloride solution as a tracer. To analyse the spatial dispersion of aerosols, Computational Fluid Dynamics (CFD) simulations were conducted in addition to experimental investigations. The investigations indicated the lowest aerosol load for the venue with displacement ventilation and the highest for the naturally ventilated venue. The measurement system developed in this study provides a useful tool for assessing the effectiveness of ventilation measures in reducing airborne transmission of pathogens in indoor environments. It also proved its wide range of applications, as it can be used in variously sized and shaped indoor environments, with or without an audience.
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (2) , 446-455
A Novel Pumping Principle for a Total Artificial Heart
Objective :Total artificial hearts (TAH) serve as a temporary treatment for severe biventricular heart failure. The limited durability and complication rates of current devices hamper long-term cardiac replacement. The aim of this study was to assess the feasibility of a novel valveless pumping principle for a durable pulsatile TAH ( ShuttlePump ). Methods: The pump features a rotating and linearly shuttling piston within a cylindrical housing with two in- and outlets. With a single moving piston, the ShuttlePump delivers pulsatile flow to both systemic and pulmonary circulation. The pump and actuation system were designed iteratively based on analytical and in silico methods, utilizing finite element methods (FEM) and computational fluid dynamics (CFD). Pump characteristics were evaluated experimentally in a mock circulation loop mimicking the cardiovascular system, while hemocompatibility-related parameters were calculated numerically. Results: Pump characteristics cover the entire required operating range for a TAH, providing 2.5 – 9 L/min of flow rate against 50 – 160 mmHg arterial pressures at stroke frequencies of 1.5 – 5 Hz while balancing left and right atrial pressures. FEM analysis showed mean overall copper losses of 8.84 W, resulting in a local maximum blood temperature rise of < 2 K. The CFD results of the normalized index of hemolysis were 3.57 mg/100L, and 95% of the pump's blood volume was exchanged after 1.42 s. Conclusion and significance: This study indicates the feasibility of a novel pumping system for a TAH with numerical and experimental results substantiating further development of the ShuttlePump
- 21 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (2) , 446-455
A Novel Pumping Principle for a Total Artificial Heart
Objective :Total artificial hearts (TAH) serve as a temporary treatment for severe biventricular heart failure. The limited durability and complication rates of current devices hamper long-term cardiac replacement. The aim of this study was to assess the feasibility of a novel valveless pumping principle for a durable pulsatile TAH ( ShuttlePump ). Methods: The pump features a rotating and linearly shuttling piston within a cylindrical housing with two in- and outlets. With a single moving piston, the ShuttlePump delivers pulsatile flow to both systemic and pulmonary circulation. The pump and actuation system were designed iteratively based on analytical and in silico methods, utilizing finite element methods (FEM) and computational fluid dynamics (CFD). Pump characteristics were evaluated experimentally in a mock circulation loop mimicking the cardiovascular system, while hemocompatibility-related parameters were calculated numerically. Results: Pump characteristics cover the entire required operating range for a TAH, providing 2.5 – 9 L/min of flow rate against 50 – 160 mmHg arterial pressures at stroke frequencies of 1.5 – 5 Hz while balancing left and right atrial pressures. FEM analysis showed mean overall copper losses of 8.84 W, resulting in a local maximum blood temperature rise of < 2 K. The CFD results of the normalized index of hemolysis were 3.57 mg/100L, and 95% of the pump's blood volume was exchanged after 1.42 s. Conclusion and significance: This study indicates the feasibility of a novel pumping system for a TAH with numerical and experimental results substantiating further development of the ShuttlePump
- Open Access
Experimental Device to Evaluate Aerosol Dispersion in Venues
The COVID-19 pandemic has focused attention to the importance of understanding and mitigating the airborne transmission of pathogens in indoor environments. This study investigated the aerosol distribution in different indoor venues with varying ventilation concepts, including displacement, mixed, and natural ventilation. A measurement system was developed to investigate venue-specific aerosol distribution patterns using a sodium chloride solution as a tracer. To analyse the spatial dispersion of aerosols, Computational Fluid Dynamics (CFD) simulations were conducted in addition to experimental investigations. The investigations indicated the lowest aerosol load for the venue with displacement ventilation and the highest for the natural ventilated venue. The measurement system developed in this study provides a useful tool for assessing the effectiveness of ventilation measures in reducing airborne transmission of pathogens in indoor environments. It also proved its wide range of applications, as it can be used in various sized and shaped indoor environments, with or without an audience.
Open AccessExperimental Device to Evaluate Aerosol Dispersion in Venues
The COVID-19 pandemic has focused attention to the importance of understanding and mitigating the airborne transmission of pathogens in indoor environments. This study investigated the aerosol distribution in different indoor venues with varying ventilation concepts, including displacement, mixed, and natural ventilation. A measurement system was developed to investigate venue-specific aerosol distribution patterns using a sodium chloride solution as a tracer. To analyse the spatial dispersion of aerosols, Computational Fluid Dynamics (CFD) simulations were conducted in addition to experimental investigations. The investigations indicated the lowest aerosol load for the venue with displacement ventilation and the highest for the natural ventilated venue. The measurement system developed in this study provides a useful tool for assessing the effectiveness of ventilation measures in reducing airborne transmission of pathogens in indoor environments. It also proved its wide range of applications, as it can be used in various sized and shaped indoor environments, with or without an audience.