Zinan Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zinan Wu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Chen Wei
University of Electronic Science and Technology of China
2 shared publications- Huimin Yue
University of Electronic Science and Technology of China
2 shared publications Jialong Zhang
University of Electronic Science and Technology of China
2 shared publicationsYong Liu
University of Electronic Science and Technology of China
2 shared publications- Zhonghua Ou
School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China 1 , Chengdu 611731
2 shared publications Bokang Ren
1 shared publication
Latest Publications
- 13 May 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (10) , 2781-2784
Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure
We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.
- 13 May 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (10) , 2781-2784
Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure
We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.
- 7 March 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (6) , 10411-10419
A high-sensitivity single-light-dource triaxial atomic magnetometer with double-cell and orthogonally pumped structure
We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.
- 7 March 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (6) , 10411-10419
A high-sensitivity single-light-dource triaxial atomic magnetometer with double-cell and orthogonally pumped structure
We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.