Yaoyao Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yaoyao Xie has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Li-Zhai Pei
School of Materials Science and Engineering, Anhui University of Technology, Anhui, People’s Republic of China
3 shared publications - Zhimei Cai
Universiti Kebangsaan Malaysia / FuJian University of Technology, MALAYSIA / CHINA
3 shared publications C. G. Fan
Anhui University of Technology
2 shared publicationsD. G. Fu
Southeast University
2 shared publicationsY. Q. Pei
Anhui University of Technology
2 shared publicationsH.Y. Yu
1 shared publication
Latest Publications
- Open Access
- 11 August 2023
- Published by Wiley in Journal of Chemistry
- Vol. 2023, 1-9
A Simple Ratiometric Electrochemical Aptasensor Based on Exonuclease III-Assisted Target Recycling for Ultrasensitive Detection of Prostate Specific Antigen
Prostate specific antigen (PSA) is considered as an important biomarker in prostate cancer diagnosis. Herein, an ultrasensitive ratiometric electrochemical aptasensor was constructed for analyzing PSA. The ferrocene (Fc)-labeled thiolated hairpin probe 2 (Fc-HP2) was conjugated to the gold nanoparticles (AuNPs)-modified gold electrode (AuE) surface by Au-S bonds. With the introduction of PSA, the aptamer region of hairpin probe 1 (HP1) preferred to bind with PSA, and the rest of HP1 could hybridize with Fc-HP2 to form Fc-HP2/HP1/PSA complex with a blunt 3 terminus, which triggered the exonuclease III (Exo III) cleavage process accompanied by Fc leaving from the electrode and recycling of HP1/PSA. The remaining Fc-HP2 fragments left on the electrode surface were then hybridized with methylene blue-labeled DNA (MB-DNA). This resulted in an enhancement of MB signal (IMB) and a decrement of Fc signal (IFc). Under the optimal conditions, the proposed aptasensor showed good analytical performance for sensitive detection of PSA with a linear range from 100fg·mL−1 to 10ng·mL−1 and a detection limit of 34.7fg·mL−1. The fabricated aptasensor had been applied to detect PSA in diluted human serum samples and obtained satisfied results, suggesting it had great potential in clinical diagnosis.
- 11 August 2023
- Published by Wiley in Journal of Chemistry
- Vol. 2023, 1-9
Open AccessA Simple Ratiometric Electrochemical Aptasensor Based on Exonuclease III-Assisted Target Recycling for Ultrasensitive Detection of Prostate Specific Antigen
Prostate specific antigen (PSA) is considered as an important biomarker in prostate cancer diagnosis. Herein, an ultrasensitive ratiometric electrochemical aptasensor was constructed for analyzing PSA. The ferrocene (Fc)-labeled thiolated hairpin probe 2 (Fc-HP2) was conjugated to the gold nanoparticles (AuNPs)-modified gold electrode (AuE) surface by Au-S bonds. With the introduction of PSA, the aptamer region of hairpin probe 1 (HP1) preferred to bind with PSA, and the rest of HP1 could hybridize with Fc-HP2 to form Fc-HP2/HP1/PSA complex with a blunt 3 terminus, which triggered the exonuclease III (Exo III) cleavage process accompanied by Fc leaving from the electrode and recycling of HP1/PSA. The remaining Fc-HP2 fragments left on the electrode surface were then hybridized with methylene blue-labeled DNA (MB-DNA). This resulted in an enhancement of MB signal (IMB) and a decrement of Fc signal (IFc). Under the optimal conditions, the proposed aptasensor showed good analytical performance for sensitive detection of PSA with a linear range from 100fg·mL−1 to 10ng·mL−1 and a detection limit of 34.7fg·mL−1. The fabricated aptasensor had been applied to detect PSA in diluted human serum samples and obtained satisfied results, suggesting it had great potential in clinical diagnosis.
- 3 December 2013
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 50 (5) , 458-467
Electrochemical determination of L-cysteine using polyaniline/CuGeO3 nanowire modified electrode
The 10 wt % polyaniline/CuGeO3nanowire modified glassy carbon electrode has been used for the electrochemical determination of L-cysteine. The electrochemical behavior of L-cysteine at the 10 wt %...
- 3 December 2013
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 50 (5) , 458-467
Electrochemical determination of L-cysteine using polyaniline/CuGeO3 nanowire modified electrode
The 10 wt % polyaniline/CuGeO3nanowire modified glassy carbon electrode has been used for the electrochemical determination of L-cysteine. The electrochemical behavior of L-cysteine at the 10 wt %...
- 1 July 2013
- Published by Elsevier in Materials Research Bulletin
- Vol. 48 (7) , 2557-2565
Hydrothermal synthesis of Mn vanadate nanosheets and visible-light photocatalytic performance for the degradation of methyl blue
- 1 July 2013
- Published by Elsevier in Materials Research Bulletin
- Vol. 48 (7) , 2557-2565
Hydrothermal synthesis of Mn vanadate nanosheets and visible-light photocatalytic performance for the degradation of methyl blue
- 1 January 2012
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 159 (3) , K55-K60
Electrochemical Behavior of Ascorbic Acid at Copper Germanate Nanowire Modified Electrode
Copper germanate (CuGeO3) nanowires are used as the modified materials of glassy carbon electrode to investigate the electrochemical behavior of ascorbic acid. The results show that CuGeO3 nanowire modified glassy carbon electrode exhibits good performance for the electrochemical detection of ascorbic acid in neutral solution. The intensities of two anodic peaks vary linearly with the concentration of ascorbic acid in the range of 0.01–5 mM and the detection limit is 24 μM and 8.6 μM, respectively at a signal-to-noise ratio of 3, which makes it possible to sensitive detection of ascorbic acid using the CuGeO3 nanowire modified glassy carbon electrode. The CuGeO3 nanowire modified electrode exhibits good reproducibility and stability. The good analytical performance makes that the CuGeO3 nanowires can be used as the electrode modified materials for a wide range of potential application for detecting ascorbic acid.
- 1 January 2012
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 159 (3) , K55-K60
Electrochemical Behavior of Ascorbic Acid at Copper Germanate Nanowire Modified Electrode
Copper germanate (CuGeO3) nanowires are used as the modified materials of glassy carbon electrode to investigate the electrochemical behavior of ascorbic acid. The results show that CuGeO3 nanowire modified glassy carbon electrode exhibits good performance for the electrochemical detection of ascorbic acid in neutral solution. The intensities of two anodic peaks vary linearly with the concentration of ascorbic acid in the range of 0.01–5 mM and the detection limit is 24 μM and 8.6 μM, respectively at a signal-to-noise ratio of 3, which makes it possible to sensitive detection of ascorbic acid using the CuGeO3 nanowire modified glassy carbon electrode. The CuGeO3 nanowire modified electrode exhibits good reproducibility and stability. The good analytical performance makes that the CuGeO3 nanowires can be used as the electrode modified materials for a wide range of potential application for detecting ascorbic acid.