Aminolah Hasanvand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Aminolah Hasanvand has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ali Khaleghi
Department of Electronic Systems, Norwegian University of Science and Technology, Trondheim, Norway
1 shared publication - Ilangko Balasingham
Department of Electronic Systems, Norwegian University of Science and Technology, Trondheim, Norway
1 shared publication - Maoyuan Li
The University of Electro-Communications
1 shared publication - Ram Prasadh Narayanan
Affiliation Walton Institute, Southeast Technological University, Waterford, Ireland
1 shared publication
Latest Publications
- 16 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 6442-6454
A New Design and Analysis for Metasurface-Based Near-Field Magnetic Wireless Power Transfer for Deep Implants
Wireless power transfer (WPT) is a crucial enabler for the long-term powering of existing implantable medical devices (IMDs). This article proposes a new design and analysis methodology for a tunable metasurface (MTS) based near-field magnetic WPT system. A near-field magnetic WPT system using a multi-coil topology creates stable power with a low specific absorption rate. However, maintaining the optimal performance of a system under misalignment conditions continues to be a challenging issue. To address this issue, the proposed design method enables the optimal coupling of the WPT system by tuning the system capacitances at a fixed frequency. Moreover, it is undefined to accurately determine the effective permeability of the MTS in the near-field range. Therefore, based on optimized results, a method is proposed to retrieve effective permeability in near-field scenarios. The effective permeability results are distinct from the typical response of the Lorentz oscillator. As a result, the specific connection between the optimization method and retrieval of effective permeability has been established. The methodology is applied to an exemplified system, where the maximal simulated and measured power transfer efficiencies at an implant depth of 8 cm are 2.32% and 2.60%, respectively. In addition, the planar MTS exhibits a high lateral misalignment tolerance, thereby enabling the development of a reliable WPT system for continuous power supply to IMDs.
- 16 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 6442-6454
A New Design and Analysis for Metasurface-Based Near-Field Magnetic Wireless Power Transfer for Deep Implants
Wireless power transfer (WPT) is a crucial enabler for the long-term powering of existing implantable medical devices (IMDs). This article proposes a new design and analysis methodology for a tunable metasurface (MTS) based near-field magnetic WPT system. A near-field magnetic WPT system using a multi-coil topology creates stable power with a low specific absorption rate. However, maintaining the optimal performance of a system under misalignment conditions continues to be a challenging issue. To address this issue, the proposed design method enables the optimal coupling of the WPT system by tuning the system capacitances at a fixed frequency. Moreover, it is undefined to accurately determine the effective permeability of the MTS in the near-field range. Therefore, based on optimized results, a method is proposed to retrieve effective permeability in near-field scenarios. The effective permeability results are distinct from the typical response of the Lorentz oscillator. As a result, the specific connection between the optimization method and retrieval of effective permeability has been established. The methodology is applied to an exemplified system, where the maximal simulated and measured power transfer efficiencies at an implant depth of 8 cm are 2.32% and 2.60%, respectively. In addition, the planar MTS exhibits a high lateral misalignment tolerance, thereby enabling the development of a reliable WPT system for continuous power supply to IMDs.