Sanjeev Sharma
Research Subjects
Sanjeev Sharma has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Naveen Kumar
University of Delhi
1 shared publication - Neeraj Kumar Sharma
University of Delhi
1 shared publication - Rakesh Kumar Gupta
Department of Microbiology, Ram Lal Anand College, University of Delhi, South Campus, New Delhi, India
1 shared publication - Sakeena Shahid
University of Delhi
1 shared publication - Subodh Kumar
Central University of Rajasthan
1 shared publication
Latest Publications
- Open Access
- 25 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-8
Predicting Depth of Anesthesia using EEG Signals and Deep Convolution Network
Depth of Anesthesia is the degree of reversible unconsciousness achieved through anesthetic agents. An appropriate anesthetic depth must be maintained during surgical procedures to prevent perioperative complications. Electroencephalogram (EEG) signals allow us to capture the extent of brain activity in various stages of anesthesia. EEG signals thereby help anesthesiologists make informed decisions regarding the administration of anesthesia based on the extent of brain activity displayed by a patient. Bi-spectral Index (BIS) monitors use features extracted from EEG signal to display the depth of anesthesia as a value between 0 and 100. However, the algorithm behind BIS monitors’ functioning is unknown and these are costly machines. Under these circumstances, patient care or monitoring becomes entirely dependent on anesthesiologists’ experience. In this paper, we propose a model using deep Convolutional Neural Network (CNN) to predict the depth of anesthesia into three classes (Anesthesia Light, Anesthesia OK, Anesthesia Deep). The input of this network is a spectrogram obtained using Short-Time Fourier Transform (STFT) applied to EEG signals. This choice of using an STFT-derived spectrogram was made based on CNN’s superior performance over raw EEG waveforms-based CNN. The trained model achieved an accuracy of 90.8%. Experimental results reveal that the proposed scheme utilizing spectrograms achieves either superior or similar performance as compared to other works for accuracy and sensitivity even though it uses relatively fewer parameters. Further, beyond traditional evaluation metrics, this study employs F1-score and precision as additional criteria for assessing the proposed scheme, offering a comprehensive view of its efficacy.
- 25 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-8
Open AccessPredicting Depth of Anesthesia using EEG Signals and Deep Convolution Network
Depth of Anesthesia is the degree of reversible unconsciousness achieved through anesthetic agents. An appropriate anesthetic depth must be maintained during surgical procedures to prevent perioperative complications. Electroencephalogram (EEG) signals allow us to capture the extent of brain activity in various stages of anesthesia. EEG signals thereby help anesthesiologists make informed decisions regarding the administration of anesthesia based on the extent of brain activity displayed by a patient. Bi-spectral Index (BIS) monitors use features extracted from EEG signal to display the depth of anesthesia as a value between 0 and 100. However, the algorithm behind BIS monitors’ functioning is unknown and these are costly machines. Under these circumstances, patient care or monitoring becomes entirely dependent on anesthesiologists’ experience. In this paper, we propose a model using deep Convolutional Neural Network (CNN) to predict the depth of anesthesia into three classes (Anesthesia Light, Anesthesia OK, Anesthesia Deep). The input of this network is a spectrogram obtained using Short-Time Fourier Transform (STFT) applied to EEG signals. This choice of using an STFT-derived spectrogram was made based on CNN’s superior performance over raw EEG waveforms-based CNN. The trained model achieved an accuracy of 90.8%. Experimental results reveal that the proposed scheme utilizing spectrograms achieves either superior or similar performance as compared to other works for accuracy and sensitivity even though it uses relatively fewer parameters. Further, beyond traditional evaluation metrics, this study employs F1-score and precision as additional criteria for assessing the proposed scheme, offering a comprehensive view of its efficacy.