BYBin Yao

Bin Yao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bin Yao has a total of 46 co-authors. Here are the top co-authors by number of shared publications:

  • Feng Zhou

    School of Aerospace Science and Technology Xidian University Xi'an China

    4 shared publications
  • Fengdeng Jin

    School of Aerospace Science and Technology Xidian University Xi'an China

    3 shared publications
  • Ziqi Meng

    School of Electronic Engineering Xidian University Xi'an China

    3 shared publications
  • Congyi Chen

    School of Aerospace Science and Technology, Xidian University, Xian, China

    2 shared publications
  • Guang Yang

    National Engineering Research Center of Electromagnetic Radiation Control Materials, School of Electronic Science and Engineering University of Electronic Science and Technology of China Chengdu China

    2 shared publications
  • Lei Shi

    School of Aerospace Science and Technology Xidian University Xi'an China

    2 shared publications

Latest Publications

  • Open Access

    Geometry‐Encoded Soft Strain Sensing via Liquid‐Metal Transmission Lines

    by Zhang Liu, Fengdeng Jin, Wenxuan Shi, Meng She, Ziqi Meng, Miao Fang, Yixin Zhang, Qianwen Dong, Wandi Yang, Lei Shi, et al.

    Reliable strain sensing in soft systems remains challenging under mechanically complex conditions, where compression, folding, transverse deformation, and environmental perturbations often interfere with tensile‐strain readout. Existing flexible strain sensors typically rely on amplitude‐based electrical responses and therefore frequently require calibration, compensation, or signal reconstruction to isolate axial deformation. Here, we present a soft liquid‐metal transmission‐line sensor that directly encodes axial elongation into the time‐of‐flight of an electromagnetic pulse. Because the readout is governed by the total propagation path length, deformation modes that do not alter this path—including localized compression, folding, and biaxial transverse strain—produce negligible influence on the measured signal. The sensor exhibits linear strain response over a wide working range up to 400% strain, together with a strain‐range–independent length resolution of 10 mm. Owing to its geometry‐governed mechanism, the device enables self‐referenced and calibration‐free strain measurement with strong inter‐device consistency, while maintaining stable operation under large pre‐strain, cyclic loading, and irreversible deformation. Reliable sensing is further demonstrated on curved surfaces, wearable systems, inflatable structures, pneumatic artificial muscles, and task‐level clinical tourniquet monitoring under dynamically varying deformation conditions. This work provides a robust and reconstruction‐free strategy for strain sensing in soft electronics, wearable systems, and clinical healthcare.

  • Exploring the Active Roles of Fluorinated Ionic Polyacrylamide Copolymer on Electrolyte Performance Improvement for Lithium Metal Batteries

    by Haolan Li, Liangliang Shi, Huanyong Liu, Xucheng Gao, Bin Yao, Guang Yang

    Polymer electrolytes have attracted wide attention for improving the interfacial stability and safety of lithium metal batteries (LMBs). Understanding how the polymer chemical structure influences the ion conduction/environment, and electrochemical properties is quite important. Herein, fluorinated polyacrylamide‐based ionic copolymer was constructed with liquid carbonate electrolyte by in situ photopolymerization to form gel polymer electrolyte (GPE) named MTA. The copolymer skeleton in MTA effectively coordinates with Li + weakly and immobilizes TFSI − anion, resulting in rapid Li + conduction (6.9 × 10 − 4 S cm − 1 ) and high Li + transference number (0.56). Meanwhile, the copolymer chain also interacts with liquid electrolyte molecules, thus improving the Li + solvation environment with more TFSI‐ anions involved. This tuned Li + solvation environment contributes to stable and LiF/Li 3 N‐rich solid electrolyte interphase (SEI) on lithium metal. As a result, the Li/MTA/Li symmetric cell shows outstanding long cycling stability over 2500 h. Moreover, Li/MTA/NCM811 cell shows capacity retention of 96% after 100 cycles at 0.2 C. Li/MTA/LiCoO 2 cell cycles stably over 120 cycles at 0.2 C. The cathode electrolyte interphase (CEI) on NCM811 is uniform and LiF‐rich. At 0.1 C, the Li/MTA/NCM811 pouch cell retains 87% of its capacity after 50 cycles. It also proves good safety and could work under bending and cutting.

  • Geometry-defined tensile deformation sensing via electromagnetic phase delay in a liquid-metal conduit

    by Yihang Zeng, Yang Gao, Bin Yao, Fengdeng Jin, Chengyang He, Wenxuan Shi, Zhongyuan Zhao, Baojun Wang, Guang Yang, Feng Zhou

    Reliable measurement of tensile deformation in soft and stretchable systems is challenging because elongation in practical settings is rarely isolated and is commonly accompanied by localized bending, compression, and temperature/humidity variations. Conventional strain sensors infer deformation from changes in electrical response amplitude, which are sensitive to such local perturbations and, therefore, provide ambiguous readout under complex deformation states. Here, tensile deformation is measured through the electromagnetic phase delay accumulated by a guided wave propagating along a deformable liquid-metal conduit. The phase delay depends on the total propagation length, establishing a direct correspondence between phase and global geometric elongation. Localized bending, compression, and moderate temperature variations affect the conduit only over confined regions and, therefore, contribute negligibly to the path-integrated phase delay, allowing the readout to reflect global elongation. The phase-based measurement exhibits a highly linear response to tensile deformation (R2 > 0.998), supports flexible definition of the reference state, and enables stable length monitoring on pre-strained, curved, and dynamically deforming surfaces. This approach provides a physical route for length measurement in soft systems under complex deformation states.


  • Top Cited Papers

    Switchable Electromagnetic Absorption and Shielding in Liquid Metal‐ZnO Ceramics via Ultralow‐Electric‐Field

    by Mingming Si, Bin Yao, Qi Ding, Zhe Liu, Peng Wei, Feng Zhou, Yuchi Fan, Wan Jiang

    Conventional electromagnetic shielding and absorbing materials are constrained by intrinsic dielectric and magnetic responses, rendering them inadequate for multi‐band communication, reconfigurable electronics, and adaptive stealth technologies. Here, we report a ZnO–liquid Ga composite ceramic that enables electric‐field‐driven switching between electromagnetic absorption and shielding under ultralow external electric fields. By tailoring interfacial reactions during cold sintering, a hierarchical ZnO/ZnGa 2 O 4 /Ga 2 O 3 /Ga heterointerface network is constructed. This architecture synergistically regulates interfacial polarization and field‐dependent carrier transport, enabling simultaneously ultrahigh‐intensity and broadband electromagnetic absorption (reflection loss of −70.1 dB at 1.91 mm with an effective bandwidth exceeding 6 GHz), together with outstanding electrical nonlinearity (α ≈ 445) and an ultralow threshold field (−1 ). Below the threshold field, electromagnetic attenuation is dominated by interfacial polarization loss, whereas exceeding the threshold induces a sharp conductivity increase via interfacial barrier modulation, driving a transition to a shielding‐dominated state. In this regime, the composite exhibits a theoretically estimated shielding effectiveness exceeding 35 dB across 2–18 GHz based on experimentally measured conductivity, thereby realizing dynamic switching between absorption and shielding modes. This work establishes a new paradigm for heterointerface‐engineered, cold‐sintered ceramics toward intelligent electromagnetic protection materials with externally controllable functionality.


  • Stretchable Strain Sensors Based on Liquid Metal Channels with Simultaneous Significant Improvements in Linearity and Sensitivity

    by Bin Yao, Yaxuan Zhu, Fengdeng Jin, Zhang Liu, Ziqi Meng, Lei Shi, Guang Yang, Qibin Yuan, Yifei Wang, Xinyi Li, et al.

    Achieving high linearity, sensitivity, and stability simultaneously in stretchable strain sensors is critical for applications such as wearable electronics, human–machine interfaces, and structural safety monitoring. However, balancing these attributes remains a significant challenge. Here, a stretchable liquid metal (LM)‐based strain sensor that combines exceptional linearity ( R 2 ≈ 0.996 over 0% to 120% strain), sufficient sensitivity (≈8), and high stability (low drift error of ≈1.2% at 50% strain for 12 h, >10 000 stretching cycles) is presented. The sensor is constructed from an LM channel embedded with soft elastomeric foam infused with LM, all encapsulated in an elastomer. The embedded foam acts as a strain‐responsive gate, controlling the connectivity pathways of the LM for electron flow. Under strain‐free conditions, the LM exhibits high connectivity and low resistance, while under tensile deformation, it transitions to reduced connectivity and increased resistance, resulting in a highly linear resistance‐strain response. Notably, the sensor's exceptional linearity simplifies calibration, reduces installation complexity, and ensures accurate measurements even under pre‐strain or zero‐clearing conditions. By integrating these key performance features, this sensor provides an effective solution for accurate strain sensing in wearable electronics, structural health monitoring, and human–machine interaction applications.


  • Stretchable Grid Liquid-Metal Channels With Predictable Strain-Resistance

    by Bin Yao, Congyi Chen, Yuwei Hu, Qiyu Huang, Ziqi Meng, Xujia Zhao, Feihua Liu, Hong Wang

    Stretchable conductors are crucial for flexible electronics, where the prediction of resistance—both as-fabricated and under strain—is essential for designing circuits. Existing conductors, however, lack this predictive capability. To address this, we developed a novel method for creating conductors with predictable resistance. This design uses liquid metal channel structures, exploiting the principle that resistance increases along the stretch direction and decreases perpendicular to it. By arranging these channels in grid patterns with adjustable length ratios, we gain precise control over resistance and its dynamic response to strain. We present stretchable Joule heating electrodes that deliver strain-insensitive temperature outputs, demonstrating the potential of our method for developing soft electronics with predefined electrical characteristics. This approach enhances both the predictability and functionality of stretchable conductors while filling a gap in soft electronics.


  • Ultrasensitive, Highly Stable, and Stretchable Strain Sensor Using Gated Liquid Metal Channel

    by Bin Yao, Xiaozhou Lü, Yanwei Wang, Nini Bai, Congyi Chen, Shaowei Wang, Haijun Su, Yunke Zhang

    Developing stretchable strain sensors with high sensitivity and stability is crucial for various applications such as prosthetic hands, human health monitoring, and human‐machine interactions. However, achieving these qualities simultaneously remains challenging. Here, an inherently stretchable strain sensor is presented that integrates ultrahigh sensitivity and robust stability, enabling stretch, press, or bend sensing capabilities. This sensor employs a softer elastomeric channel filled with liquid metal (LM) as the conductive path. A stiffer elastomer convex integrated into the channel serves as a strain‐manipulated gate, controlling opening gap of electrical current flow path. During deformation, the softer elastomer undergoes cross sectional reduction due to the Poisson effect, while the stiffer convex gate retains its geometry. This heterogeneous deformation behavior leads to significant contraction or closure of the LM channel, resulting in increased resistance and a remarkable enhancement in sensitivity by more than two orders of magnitude. The all‐soft design maintains exceptional stability even under extended or repetitive substantial deformations. With the ability to monitor subtle and large human body movements, detect grip actions of soft grippers reliably, and monitor the gradual and extended growth process of plants, this sensor holds significant potential for advancements in flexible electronics.