Bin Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bin Yao has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Feng Zhou
School of Aerospace Science and Technology Xidian University Xi'an China
4 shared publicationsFengdeng Jin
School of Aerospace Science and Technology Xidian University Xi'an China
3 shared publicationsZiqi Meng
School of Electronic Engineering Xidian University Xi'an China
3 shared publicationsCongyi Chen
School of Aerospace Science and Technology, Xidian University, Xian, China
2 shared publications- Guang Yang
National Engineering Research Center of Electromagnetic Radiation Control Materials, School of Electronic Science and Engineering University of Electronic Science and Technology of China Chengdu China
2 shared publications Lei Shi
School of Aerospace Science and Technology Xidian University Xi'an China
2 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by Wiley in Advanced Science
- p. e77839
Geometry‐Encoded Soft Strain Sensing via Liquid‐Metal Transmission Lines
Reliable strain sensing in soft systems remains challenging under mechanically complex conditions, where compression, folding, transverse deformation, and environmental perturbations often interfere with tensile‐strain readout. Existing flexible strain sensors typically rely on amplitude‐based electrical responses and therefore frequently require calibration, compensation, or signal reconstruction to isolate axial deformation. Here, we present a soft liquid‐metal transmission‐line sensor that directly encodes axial elongation into the time‐of‐flight of an electromagnetic pulse. Because the readout is governed by the total propagation path length, deformation modes that do not alter this path—including localized compression, folding, and biaxial transverse strain—produce negligible influence on the measured signal. The sensor exhibits linear strain response over a wide working range up to 400% strain, together with a strain‐range–independent length resolution of 10 mm. Owing to its geometry‐governed mechanism, the device enables self‐referenced and calibration‐free strain measurement with strong inter‐device consistency, while maintaining stable operation under large pre‐strain, cyclic loading, and irreversible deformation. Reliable sensing is further demonstrated on curved surfaces, wearable systems, inflatable structures, pneumatic artificial muscles, and task‐level clinical tourniquet monitoring under dynamically varying deformation conditions. This work provides a robust and reconstruction‐free strategy for strain sensing in soft electronics, wearable systems, and clinical healthcare.
- 16 September 2026
- Published by Wiley in Advanced Science
- p. e77839
Open AccessGeometry‐Encoded Soft Strain Sensing via Liquid‐Metal Transmission Lines
Reliable strain sensing in soft systems remains challenging under mechanically complex conditions, where compression, folding, transverse deformation, and environmental perturbations often interfere with tensile‐strain readout. Existing flexible strain sensors typically rely on amplitude‐based electrical responses and therefore frequently require calibration, compensation, or signal reconstruction to isolate axial deformation. Here, we present a soft liquid‐metal transmission‐line sensor that directly encodes axial elongation into the time‐of‐flight of an electromagnetic pulse. Because the readout is governed by the total propagation path length, deformation modes that do not alter this path—including localized compression, folding, and biaxial transverse strain—produce negligible influence on the measured signal. The sensor exhibits linear strain response over a wide working range up to 400% strain, together with a strain‐range–independent length resolution of 10 mm. Owing to its geometry‐governed mechanism, the device enables self‐referenced and calibration‐free strain measurement with strong inter‐device consistency, while maintaining stable operation under large pre‐strain, cyclic loading, and irreversible deformation. Reliable sensing is further demonstrated on curved surfaces, wearable systems, inflatable structures, pneumatic artificial muscles, and task‐level clinical tourniquet monitoring under dynamically varying deformation conditions. This work provides a robust and reconstruction‐free strategy for strain sensing in soft electronics, wearable systems, and clinical healthcare.
Exploring the Active Roles of Fluorinated Ionic Polyacrylamide Copolymer on Electrolyte Performance Improvement for Lithium Metal Batteries
Polymer electrolytes have attracted wide attention for improving the interfacial stability and safety of lithium metal batteries (LMBs). Understanding how the polymer chemical structure influences the ion conduction/environment, and electrochemical properties is quite important. Herein, fluorinated polyacrylamide‐based ionic copolymer was constructed with liquid carbonate electrolyte by in situ photopolymerization to form gel polymer electrolyte (GPE) named MTA. The copolymer skeleton in MTA effectively coordinates with Li + weakly and immobilizes TFSI − anion, resulting in rapid Li + conduction (6.9 × 10 − 4 S cm − 1 ) and high Li + transference number (0.56). Meanwhile, the copolymer chain also interacts with liquid electrolyte molecules, thus improving the Li + solvation environment with more TFSI‐ anions involved. This tuned Li + solvation environment contributes to stable and LiF/Li 3 N‐rich solid electrolyte interphase (SEI) on lithium metal. As a result, the Li/MTA/Li symmetric cell shows outstanding long cycling stability over 2500 h. Moreover, Li/MTA/NCM811 cell shows capacity retention of 96% after 100 cycles at 0.2 C. Li/MTA/LiCoO 2 cell cycles stably over 120 cycles at 0.2 C. The cathode electrolyte interphase (CEI) on NCM811 is uniform and LiF‐rich. At 0.1 C, the Li/MTA/NCM811 pouch cell retains 87% of its capacity after 50 cycles. It also proves good safety and could work under bending and cutting.
Exploring the Active Roles of Fluorinated Ionic Polyacrylamide Copolymer on Electrolyte Performance Improvement for Lithium Metal Batteries
Polymer electrolytes have attracted wide attention for improving the interfacial stability and safety of lithium metal batteries (LMBs). Understanding how the polymer chemical structure influences the ion conduction/environment, and electrochemical properties is quite important. Herein, fluorinated polyacrylamide‐based ionic copolymer was constructed with liquid carbonate electrolyte by in situ photopolymerization to form gel polymer electrolyte (GPE) named MTA. The copolymer skeleton in MTA effectively coordinates with Li + weakly and immobilizes TFSI − anion, resulting in rapid Li + conduction (6.9 × 10 − 4 S cm − 1 ) and high Li + transference number (0.56). Meanwhile, the copolymer chain also interacts with liquid electrolyte molecules, thus improving the Li + solvation environment with more TFSI‐ anions involved. This tuned Li + solvation environment contributes to stable and LiF/Li 3 N‐rich solid electrolyte interphase (SEI) on lithium metal. As a result, the Li/MTA/Li symmetric cell shows outstanding long cycling stability over 2500 h. Moreover, Li/MTA/NCM811 cell shows capacity retention of 96% after 100 cycles at 0.2 C. Li/MTA/LiCoO 2 cell cycles stably over 120 cycles at 0.2 C. The cathode electrolyte interphase (CEI) on NCM811 is uniform and LiF‐rich. At 0.1 C, the Li/MTA/NCM811 pouch cell retains 87% of its capacity after 50 cycles. It also proves good safety and could work under bending and cutting.
- 23 February 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (8)
Geometry-defined tensile deformation sensing via electromagnetic phase delay in a liquid-metal conduit
Reliable measurement of tensile deformation in soft and stretchable systems is challenging because elongation in practical settings is rarely isolated and is commonly accompanied by localized bending, compression, and temperature/humidity variations. Conventional strain sensors infer deformation from changes in electrical response amplitude, which are sensitive to such local perturbations and, therefore, provide ambiguous readout under complex deformation states. Here, tensile deformation is measured through the electromagnetic phase delay accumulated by a guided wave propagating along a deformable liquid-metal conduit. The phase delay depends on the total propagation length, establishing a direct correspondence between phase and global geometric elongation. Localized bending, compression, and moderate temperature variations affect the conduit only over confined regions and, therefore, contribute negligibly to the path-integrated phase delay, allowing the readout to reflect global elongation. The phase-based measurement exhibits a highly linear response to tensile deformation (R2 > 0.998), supports flexible definition of the reference state, and enables stable length monitoring on pre-strained, curved, and dynamically deforming surfaces. This approach provides a physical route for length measurement in soft systems under complex deformation states.
- 23 February 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (8)
Geometry-defined tensile deformation sensing via electromagnetic phase delay in a liquid-metal conduit
Reliable measurement of tensile deformation in soft and stretchable systems is challenging because elongation in practical settings is rarely isolated and is commonly accompanied by localized bending, compression, and temperature/humidity variations. Conventional strain sensors infer deformation from changes in electrical response amplitude, which are sensitive to such local perturbations and, therefore, provide ambiguous readout under complex deformation states. Here, tensile deformation is measured through the electromagnetic phase delay accumulated by a guided wave propagating along a deformable liquid-metal conduit. The phase delay depends on the total propagation length, establishing a direct correspondence between phase and global geometric elongation. Localized bending, compression, and moderate temperature variations affect the conduit only over confined regions and, therefore, contribute negligibly to the path-integrated phase delay, allowing the readout to reflect global elongation. The phase-based measurement exhibits a highly linear response to tensile deformation (R2 > 0.998), supports flexible definition of the reference state, and enables stable length monitoring on pre-strained, curved, and dynamically deforming surfaces. This approach provides a physical route for length measurement in soft systems under complex deformation states.
- Top Cited Papers
- 26 January 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (35)
Switchable Electromagnetic Absorption and Shielding in Liquid Metal‐ZnO Ceramics via Ultralow‐Electric‐Field
Conventional electromagnetic shielding and absorbing materials are constrained by intrinsic dielectric and magnetic responses, rendering them inadequate for multi‐band communication, reconfigurable electronics, and adaptive stealth technologies. Here, we report a ZnO–liquid Ga composite ceramic that enables electric‐field‐driven switching between electromagnetic absorption and shielding under ultralow external electric fields. By tailoring interfacial reactions during cold sintering, a hierarchical ZnO/ZnGa 2 O 4 /Ga 2 O 3 /Ga heterointerface network is constructed. This architecture synergistically regulates interfacial polarization and field‐dependent carrier transport, enabling simultaneously ultrahigh‐intensity and broadband electromagnetic absorption (reflection loss of −70.1 dB at 1.91 mm with an effective bandwidth exceeding 6 GHz), together with outstanding electrical nonlinearity (α ≈ 445) and an ultralow threshold field (−1 ). Below the threshold field, electromagnetic attenuation is dominated by interfacial polarization loss, whereas exceeding the threshold induces a sharp conductivity increase via interfacial barrier modulation, driving a transition to a shielding‐dominated state. In this regime, the composite exhibits a theoretically estimated shielding effectiveness exceeding 35 dB across 2–18 GHz based on experimentally measured conductivity, thereby realizing dynamic switching between absorption and shielding modes. This work establishes a new paradigm for heterointerface‐engineered, cold‐sintered ceramics toward intelligent electromagnetic protection materials with externally controllable functionality.
- 26 January 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (35)
Top Cited PapersSwitchable Electromagnetic Absorption and Shielding in Liquid Metal‐ZnO Ceramics via Ultralow‐Electric‐Field
Conventional electromagnetic shielding and absorbing materials are constrained by intrinsic dielectric and magnetic responses, rendering them inadequate for multi‐band communication, reconfigurable electronics, and adaptive stealth technologies. Here, we report a ZnO–liquid Ga composite ceramic that enables electric‐field‐driven switching between electromagnetic absorption and shielding under ultralow external electric fields. By tailoring interfacial reactions during cold sintering, a hierarchical ZnO/ZnGa 2 O 4 /Ga 2 O 3 /Ga heterointerface network is constructed. This architecture synergistically regulates interfacial polarization and field‐dependent carrier transport, enabling simultaneously ultrahigh‐intensity and broadband electromagnetic absorption (reflection loss of −70.1 dB at 1.91 mm with an effective bandwidth exceeding 6 GHz), together with outstanding electrical nonlinearity (α ≈ 445) and an ultralow threshold field (−1 ). Below the threshold field, electromagnetic attenuation is dominated by interfacial polarization loss, whereas exceeding the threshold induces a sharp conductivity increase via interfacial barrier modulation, driving a transition to a shielding‐dominated state. In this regime, the composite exhibits a theoretically estimated shielding effectiveness exceeding 35 dB across 2–18 GHz based on experimentally measured conductivity, thereby realizing dynamic switching between absorption and shielding modes. This work establishes a new paradigm for heterointerface‐engineered, cold‐sintered ceramics toward intelligent electromagnetic protection materials with externally controllable functionality.
- 6 September 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (12)
Stretchable Strain Sensors Based on Liquid Metal Channels with Simultaneous Significant Improvements in Linearity and Sensitivity
Achieving high linearity, sensitivity, and stability simultaneously in stretchable strain sensors is critical for applications such as wearable electronics, human–machine interfaces, and structural safety monitoring. However, balancing these attributes remains a significant challenge. Here, a stretchable liquid metal (LM)‐based strain sensor that combines exceptional linearity ( R 2 ≈ 0.996 over 0% to 120% strain), sufficient sensitivity (≈8), and high stability (low drift error of ≈1.2% at 50% strain for 12 h, >10 000 stretching cycles) is presented. The sensor is constructed from an LM channel embedded with soft elastomeric foam infused with LM, all encapsulated in an elastomer. The embedded foam acts as a strain‐responsive gate, controlling the connectivity pathways of the LM for electron flow. Under strain‐free conditions, the LM exhibits high connectivity and low resistance, while under tensile deformation, it transitions to reduced connectivity and increased resistance, resulting in a highly linear resistance‐strain response. Notably, the sensor's exceptional linearity simplifies calibration, reduces installation complexity, and ensures accurate measurements even under pre‐strain or zero‐clearing conditions. By integrating these key performance features, this sensor provides an effective solution for accurate strain sensing in wearable electronics, structural health monitoring, and human–machine interaction applications.
- 6 September 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (12)
Stretchable Strain Sensors Based on Liquid Metal Channels with Simultaneous Significant Improvements in Linearity and Sensitivity
Achieving high linearity, sensitivity, and stability simultaneously in stretchable strain sensors is critical for applications such as wearable electronics, human–machine interfaces, and structural safety monitoring. However, balancing these attributes remains a significant challenge. Here, a stretchable liquid metal (LM)‐based strain sensor that combines exceptional linearity ( R 2 ≈ 0.996 over 0% to 120% strain), sufficient sensitivity (≈8), and high stability (low drift error of ≈1.2% at 50% strain for 12 h, >10 000 stretching cycles) is presented. The sensor is constructed from an LM channel embedded with soft elastomeric foam infused with LM, all encapsulated in an elastomer. The embedded foam acts as a strain‐responsive gate, controlling the connectivity pathways of the LM for electron flow. Under strain‐free conditions, the LM exhibits high connectivity and low resistance, while under tensile deformation, it transitions to reduced connectivity and increased resistance, resulting in a highly linear resistance‐strain response. Notably, the sensor's exceptional linearity simplifies calibration, reduces installation complexity, and ensures accurate measurements even under pre‐strain or zero‐clearing conditions. By integrating these key performance features, this sensor provides an effective solution for accurate strain sensing in wearable electronics, structural health monitoring, and human–machine interaction applications.
- 6 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 46 (8) , 1381-1384
Stretchable Grid Liquid-Metal Channels With Predictable Strain-Resistance
Stretchable conductors are crucial for flexible electronics, where the prediction of resistance—both as-fabricated and under strain—is essential for designing circuits. Existing conductors, however, lack this predictive capability. To address this, we developed a novel method for creating conductors with predictable resistance. This design uses liquid metal channel structures, exploiting the principle that resistance increases along the stretch direction and decreases perpendicular to it. By arranging these channels in grid patterns with adjustable length ratios, we gain precise control over resistance and its dynamic response to strain. We present stretchable Joule heating electrodes that deliver strain-insensitive temperature outputs, demonstrating the potential of our method for developing soft electronics with predefined electrical characteristics. This approach enhances both the predictability and functionality of stretchable conductors while filling a gap in soft electronics.
- 6 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 46 (8) , 1381-1384
Stretchable Grid Liquid-Metal Channels With Predictable Strain-Resistance
Stretchable conductors are crucial for flexible electronics, where the prediction of resistance—both as-fabricated and under strain—is essential for designing circuits. Existing conductors, however, lack this predictive capability. To address this, we developed a novel method for creating conductors with predictable resistance. This design uses liquid metal channel structures, exploiting the principle that resistance increases along the stretch direction and decreases perpendicular to it. By arranging these channels in grid patterns with adjustable length ratios, we gain precise control over resistance and its dynamic response to strain. We present stretchable Joule heating electrodes that deliver strain-insensitive temperature outputs, demonstrating the potential of our method for developing soft electronics with predefined electrical characteristics. This approach enhances both the predictability and functionality of stretchable conductors while filling a gap in soft electronics.
- 29 May 2024
- Published by Wiley in Advanced Functional Materials
- Vol. 34 (28)
Ultrasensitive, Highly Stable, and Stretchable Strain Sensor Using Gated Liquid Metal Channel
Developing stretchable strain sensors with high sensitivity and stability is crucial for various applications such as prosthetic hands, human health monitoring, and human‐machine interactions. However, achieving these qualities simultaneously remains challenging. Here, an inherently stretchable strain sensor is presented that integrates ultrahigh sensitivity and robust stability, enabling stretch, press, or bend sensing capabilities. This sensor employs a softer elastomeric channel filled with liquid metal (LM) as the conductive path. A stiffer elastomer convex integrated into the channel serves as a strain‐manipulated gate, controlling opening gap of electrical current flow path. During deformation, the softer elastomer undergoes cross sectional reduction due to the Poisson effect, while the stiffer convex gate retains its geometry. This heterogeneous deformation behavior leads to significant contraction or closure of the LM channel, resulting in increased resistance and a remarkable enhancement in sensitivity by more than two orders of magnitude. The all‐soft design maintains exceptional stability even under extended or repetitive substantial deformations. With the ability to monitor subtle and large human body movements, detect grip actions of soft grippers reliably, and monitor the gradual and extended growth process of plants, this sensor holds significant potential for advancements in flexible electronics.
- 29 May 2024
- Published by Wiley in Advanced Functional Materials
- Vol. 34 (28)
Ultrasensitive, Highly Stable, and Stretchable Strain Sensor Using Gated Liquid Metal Channel
Developing stretchable strain sensors with high sensitivity and stability is crucial for various applications such as prosthetic hands, human health monitoring, and human‐machine interactions. However, achieving these qualities simultaneously remains challenging. Here, an inherently stretchable strain sensor is presented that integrates ultrahigh sensitivity and robust stability, enabling stretch, press, or bend sensing capabilities. This sensor employs a softer elastomeric channel filled with liquid metal (LM) as the conductive path. A stiffer elastomer convex integrated into the channel serves as a strain‐manipulated gate, controlling opening gap of electrical current flow path. During deformation, the softer elastomer undergoes cross sectional reduction due to the Poisson effect, while the stiffer convex gate retains its geometry. This heterogeneous deformation behavior leads to significant contraction or closure of the LM channel, resulting in increased resistance and a remarkable enhancement in sensitivity by more than two orders of magnitude. The all‐soft design maintains exceptional stability even under extended or repetitive substantial deformations. With the ability to monitor subtle and large human body movements, detect grip actions of soft grippers reliably, and monitor the gradual and extended growth process of plants, this sensor holds significant potential for advancements in flexible electronics.