ZDZhiyuan Du

Zhiyuan Du

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhiyuan Du has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Guanghua Chen

    Key Laboratory of the Public Health Safety, Ministry of Education, Department of Environmental Health, School of Public Health, Fudan University, Shanghai 200032, PR China

    1 shared publication
  • Jialing Li

    Health Supervision Institute of Health Commission, Songjiang District, Shanghai 201620, PR China

    1 shared publication
  • Ming Zhan

    Shanghai Pudong New Area Center for Disease Control and Prevention, Fudan University Pudong Institute of Preventive Medicine, Shanghai 200136, PR China

    1 shared publication
  • Weiwei Zheng

    Key Laboratory of the Public Health Safety, Ministry of Education, Department of Environmental Health, School of Public Health, Fudan University, Shanghai, China

    1 shared publication
  • Xiaohua Hu

    Digital Innovation Laboratory, Information Department, The First Affiliated Hospital of Naval Military Medical University, Changhai Road 168, Shanghai, 200433, P. R. China

    1 shared publication
  • Xiaoyi Wei

    Department of Food Science, College of Hospitality of Management, Shanghai Business School, Shanghai 200235, PR China

    1 shared publication

Latest Publications

  • Organophosphate esters in human serum: a relatively simple and efficient liquid chromatography-mass spectrometry method

    by Zhiyuan Du, Xiaoyi Wei, Xiaohua Hu, Yijing Zhao, Guanghua Chen, Xiushuai Du, Jialing Li, Ming Zhan, Weiwei Zheng

    Organophosphate esters (OPEs) are widely used as flame retardants and plasticizers, which are of growing concern due to their endocrine-disrupting effects, developmental toxicity, and potential carcinogenicity. However, data on human exposure to OPEs is still scarce. In this study, a relatively simple and efficient method with less serum consumption for the detection of OPEs in human serum was developed and validated. Nine OPEs in 200 μL of human serum were extracted by an acetonitrile–formic acid system and analyzed using ultra-high-performance liquid chromatography–quadrupole tandem time-of-flight high-resolution mass spectrometry. Several experiments were conducted to optimize the chromatographic and mass spectrometric conditions as well as sample preparation to obtain a more sensitive and efficient analytical protocol. The proposed method was examined in terms of its linearity, accuracy, precision, detection limit, and matrix effect. The matrix-spiked recoveries of the target OPEs ranged from 83.3% to 111.1%, with relative standard deviations between 2.7% and 16.6%. The detection limits were within (0.002 to 0.029) ng mL−1, while the quantification limits were within (0.007 to 0.098) ng mL−1. The internal standard-corrected matrix effects varied from 82.7% to 113.9%. Finally, the method was applied to detect OPEs in actual human serum samples. All nine OPEs were detected in 269 serum samples to varying degrees, with the average concentrations ranging from (0.08 to 1.77) ng mL−1. After validation, the method was found to be simple in pretreatment, high in sensitivity, good in practicality, and suitable for exposure evaluation of OPEs in populations.