Tianyu Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tianyu Gao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Hang Yu
Institute of Advanced Science Facilities , Shenzhen, Guangdong 518107
1 shared publication - Jian-Jun Mao
Institute of Advanced Science Facilities , Shenzhen, Guangdong 518107
1 shared publication Ming Liu
Institute of Advanced Science Facilities , Shenzhen, Guangdong 518107
1 shared publication- Wei Wang
Institute of Advanced Light Source Facilities, Shenzhen 518107, Guangdong, People’s Republic of China
1 shared publication - Wen Zhong
Institute of Advanced Science Facilities , Shenzhen, Guangdong 518107
1 shared publication - Wenjie Cheng
Institute of Advanced Science Facilities
1 shared publication
Latest Publications
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
A research on improving the precision of laser tracker in alignment based on Pareto improvement principle
The accuracy of laser trackers in large-scale dimensional metrology is subject to various influencing factors, with instrument positioning being a primary source of error. To address this, a multi-objective optimization algorithm, grounded in the Pareto improvement principle, is proposed. This algorithm is designed to optimize instrument placement, thereby minimizing measurement errors and enhancing the algorithm’s efficacy in error reduction. Thereby, this article proved that positioning the laser tracker consistently on one side of the measurement area and aligning its height with the measuring points can effectively reduce the uncertainty of control point errors by up to 50%.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessA research on improving the precision of laser tracker in alignment based on Pareto improvement principle
The accuracy of laser trackers in large-scale dimensional metrology is subject to various influencing factors, with instrument positioning being a primary source of error. To address this, a multi-objective optimization algorithm, grounded in the Pareto improvement principle, is proposed. This algorithm is designed to optimize instrument placement, thereby minimizing measurement errors and enhancing the algorithm’s efficacy in error reduction. Thereby, this article proved that positioning the laser tracker consistently on one side of the measurement area and aligning its height with the measuring points can effectively reduce the uncertainty of control point errors by up to 50%.