Guangbin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guangbin Zhang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Meiyi Zhu
Cataract Department, Xiamen Eye Center and Eye Institute of Xiamen University, School of Medicine, Xiamen, People's Republic of China
6 shared publicationsZongsheng Zeng
Cataract Department, Xiamen Eye Center and Eye Institute of Xiamen University, School of Medicine, Xiamen, People's Republic of China
5 shared publicationsWei Fan
School of Medicine, Xiamen Eye Center and Eye Institute of Xiamen University, Xiamen, China
4 shared publicationsQingzhong Chen
Xiamen Eye Center Affiliated to Xiamen University, Xiamen, China
3 shared publicationsChangkai Jia
Xiamen Eye Centre, Affiliated with Xiamen University, 336 XiaHe Road, Xiamen, Fujian, China
1 shared publicationChen Wu
Xiamen Eye Center Affiliated to Xiamen University, Xiamen, China
1 shared publication
Latest Publications
- Open Access
- 1 July 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-9
Effectiveness of Topical Anesthesia in Patients Undergoing Phacoemulsification Cataract Surgery versus Femtosecond Laser-Assisted Cataract Surgery
To assess the effectiveness of topical anesthesia in patients undergoing phacoemulsification cataract surgery (PCS) and femtosecond laser-assisted cataract surgery (FLACS), and investigate an efficient anesthesia protocol for FLACS. Non-randomized, prospective cohort study. In this study, patients undergoing cataract surgery self-selected their preferred technique (PCS or FLACS; n = 100 eyes per cohort) and received three topical anesthesia applications prior to phacoemulsification. Those opting for FLACS were randomized to receive the laser phase using either the Catalys (Johnson and Johnson Vision) or LenSx (Alcon Laboratories, Inc.) system, with one topical anesthesia administration before the laser step and two prior to phacoemulsification. Outcome measures included visual analogue scale pain scores, total surgical, anesthesia, and phacoemulsification durations, and anesthesia efficacy. There was no significant difference in pain perception between the PCS and FLACS groups (P = 0.835). No statistically significant difference was observed in the total surgical duration between the PCS and FLACS groups (P = 0.736). After a single application of topical anesthesia, most patients achieved excellent cooperation during laser procedure with no pain. No significant difference in anesthetic efficacy was observed between the Catalys and LenSx laser systems. Both PCS and FLACS appeared safe and comfortable under topical anesthesia in this selected cohort. A single application of topical anesthesia was sufficient for the laser step in most FLACS patients, and the protocol of administering additional anesthesia between steps may offer a feasible strategy for workflow optimization. Anesthetic efficacy did not differ between the Catalys and LenSx systems, despite their different patient interface docking mechanisms.
- 1 July 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-9
Open AccessEffectiveness of Topical Anesthesia in Patients Undergoing Phacoemulsification Cataract Surgery versus Femtosecond Laser-Assisted Cataract Surgery
To assess the effectiveness of topical anesthesia in patients undergoing phacoemulsification cataract surgery (PCS) and femtosecond laser-assisted cataract surgery (FLACS), and investigate an efficient anesthesia protocol for FLACS. Non-randomized, prospective cohort study. In this study, patients undergoing cataract surgery self-selected their preferred technique (PCS or FLACS; n = 100 eyes per cohort) and received three topical anesthesia applications prior to phacoemulsification. Those opting for FLACS were randomized to receive the laser phase using either the Catalys (Johnson and Johnson Vision) or LenSx (Alcon Laboratories, Inc.) system, with one topical anesthesia administration before the laser step and two prior to phacoemulsification. Outcome measures included visual analogue scale pain scores, total surgical, anesthesia, and phacoemulsification durations, and anesthesia efficacy. There was no significant difference in pain perception between the PCS and FLACS groups (P = 0.835). No statistically significant difference was observed in the total surgical duration between the PCS and FLACS groups (P = 0.736). After a single application of topical anesthesia, most patients achieved excellent cooperation during laser procedure with no pain. No significant difference in anesthetic efficacy was observed between the Catalys and LenSx laser systems. Both PCS and FLACS appeared safe and comfortable under topical anesthesia in this selected cohort. A single application of topical anesthesia was sufficient for the laser step in most FLACS patients, and the protocol of administering additional anesthesia between steps may offer a feasible strategy for workflow optimization. Anesthetic efficacy did not differ between the Catalys and LenSx systems, despite their different patient interface docking mechanisms.
- Open Access
- 11 March 2026
- Published by Springer Nature in BMC Ophthalmology
- Vol. 26 (1) , 121
Evaluation of 7 modern IOL power calculation formulas in two PARTIAL-Range of Field IOL designs and a new constant optimization method
To evaluate the performance of seven modern intraocular lens (IOL) power calculation formulas in two different PARTIAL-Range of Field (RoF) extend IOL desi
- 11 March 2026
- Published by Springer Nature in BMC Ophthalmology
- Vol. 26 (1) , 121
Open AccessEvaluation of 7 modern IOL power calculation formulas in two PARTIAL-Range of Field IOL designs and a new constant optimization method
To evaluate the performance of seven modern intraocular lens (IOL) power calculation formulas in two different PARTIAL-Range of Field (RoF) extend IOL desi
- Open Access
- 21 May 2025
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1509889
Visual outcomes and spectacle independence of a non-diffractive wavefront-shaping intraocular lens in post-LASIK patients
Purpose: To compare visual outcomes, depth of field (DOF), spectacle independence, and patient satisfaction of cataract patients with and without previous myopic laser in situ keratomileusis (LASIK) surgery who received a non-diffractive extended range-of-focus (EROF) intraocular lens (IOL).Setting: Xiamen Eye Center, Xiamen, China.Design: Prospective case series.Methods: A total of 50 eyes of 41 patients implanted with the Vivity IOL were divided into Post-LASIK and Virgin groups. Outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), refractive outcomes, defocus curves, subjective DOF, spectacle independence, and Visual Function questionnaire (VF-14) after 3 months postoperatively.Results: Postoperatively, 70% of the Post-LASIK and 86.7% of the Virgin group had refractive error within ± 0.50 D (P = 0.28). The majority of both groups achieved 20/25 or better UDVA, with no significant differences between groups for UDVA, CDVA and UIVA (P > 0.05). The UNVA was significantly better in the Post-LASIK group (0.31 ± 0.08 logMAR) than Virgin group (0.45 ± 0.10 logMAR, P < 0.001). The Post-LASIK group showed a smoother curve with a wider landing area, and better subjective DOF compared to the Virgin group (P < 0.001). Spectacle independence at near ranges in bright light was higher in the Post-LASIK group (81.3 % vs 48 %, P = 0.033). Both groups reported high visual satisfaction, but the Post-LASIK group had fewer difficulties with near-distance tasks in the VF-14 questionnaire.Conclusion: In post-LASIK eyes, this wavefront-shaping EROF IOL was well-tolerated and provided an extended range of vision with significantly better UNVA, fewer difficulties in daily activities and higher spectacle independence for near vision compared to normal eyes.
- 21 May 2025
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 12, 1509889
Open AccessVisual outcomes and spectacle independence of a non-diffractive wavefront-shaping intraocular lens in post-LASIK patients
Purpose: To compare visual outcomes, depth of field (DOF), spectacle independence, and patient satisfaction of cataract patients with and without previous myopic laser in situ keratomileusis (LASIK) surgery who received a non-diffractive extended range-of-focus (EROF) intraocular lens (IOL).Setting: Xiamen Eye Center, Xiamen, China.Design: Prospective case series.Methods: A total of 50 eyes of 41 patients implanted with the Vivity IOL were divided into Post-LASIK and Virgin groups. Outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), refractive outcomes, defocus curves, subjective DOF, spectacle independence, and Visual Function questionnaire (VF-14) after 3 months postoperatively.Results: Postoperatively, 70% of the Post-LASIK and 86.7% of the Virgin group had refractive error within ± 0.50 D (P = 0.28). The majority of both groups achieved 20/25 or better UDVA, with no significant differences between groups for UDVA, CDVA and UIVA (P > 0.05). The UNVA was significantly better in the Post-LASIK group (0.31 ± 0.08 logMAR) than Virgin group (0.45 ± 0.10 logMAR, P < 0.001). The Post-LASIK group showed a smoother curve with a wider landing area, and better subjective DOF compared to the Virgin group (P < 0.001). Spectacle independence at near ranges in bright light was higher in the Post-LASIK group (81.3 % vs 48 %, P = 0.033). Both groups reported high visual satisfaction, but the Post-LASIK group had fewer difficulties with near-distance tasks in the VF-14 questionnaire.Conclusion: In post-LASIK eyes, this wavefront-shaping EROF IOL was well-tolerated and provided an extended range of vision with significantly better UNVA, fewer difficulties in daily activities and higher spectacle independence for near vision compared to normal eyes.
- Open Access
- 4 March 2025
- Published by Springer Nature in BMC Ophthalmology
- Vol. 25 (1) , 1-12
Implantation of trifocal intraocular lens in mild pathologic myopia: visual outcomes and influence of fundus structures
To compare the visual outcomes of simple high myopia (HM) and mild pathologic myopia (PM) following implantation of a trifocal intraocular lens (IOL), and investigate the influence of fundus structures. We retrospectively studied 63 high myopic eyes of 63 patients underwent femtosecond laser-assisted cataract surgery with implantation of AT LISA tri 839MP IOL (Carl Zeiss Meditec AG, Germany) between July 2020 and September 2024. 34 eyes in the HM group and 29 eyes in the PM group. Main visual outcomes including monocular corrected distance (4 m, CDVA), distance-corrected intermediate (80 cm, DCIVA), distance-corrected near (40 cm, DCNVA) visual acuity, defocus curves, and subjective refraction. Optical coherence tomograph was employed to evaluate macular tilt degree (MTD), central foveal thickness, and subfoveal choroidal thickness. Multiple linear regression analysis was used to evaluate the independent predictors of visual acuity in the PM group. The CDVA, DCIVA, and DCNVA were 0.00 ± 0.00, 0.08 ± 0.05, and 0.09 ± 0.07 logarithm of the minimum angle of resolution (logMAR) in the HM group, 0.02 ± 0.05, 0.15 ± 0.09, and 0.17 ± 0.09 logMAR in the PM group, respectively. In the PM group, mean MTD was 17.13 ± 6.79°. The MTD demonstrated a significant predictive effect on CDVA (regression coefficient: 0.005; P = 0.026) and DCNVA (regression coefficient: 0.015; P = 0.003). Trifocal IOL implantation yielded favorable visual outcomes in simple high myopic eyes, though results were comparatively poorer in PM cases. MTD was associated with the expected visual outcomes.
- 4 March 2025
- Published by Springer Nature in BMC Ophthalmology
- Vol. 25 (1) , 1-12
Open AccessImplantation of trifocal intraocular lens in mild pathologic myopia: visual outcomes and influence of fundus structures
To compare the visual outcomes of simple high myopia (HM) and mild pathologic myopia (PM) following implantation of a trifocal intraocular lens (IOL), and investigate the influence of fundus structures. We retrospectively studied 63 high myopic eyes of 63 patients underwent femtosecond laser-assisted cataract surgery with implantation of AT LISA tri 839MP IOL (Carl Zeiss Meditec AG, Germany) between July 2020 and September 2024. 34 eyes in the HM group and 29 eyes in the PM group. Main visual outcomes including monocular corrected distance (4 m, CDVA), distance-corrected intermediate (80 cm, DCIVA), distance-corrected near (40 cm, DCNVA) visual acuity, defocus curves, and subjective refraction. Optical coherence tomograph was employed to evaluate macular tilt degree (MTD), central foveal thickness, and subfoveal choroidal thickness. Multiple linear regression analysis was used to evaluate the independent predictors of visual acuity in the PM group. The CDVA, DCIVA, and DCNVA were 0.00 ± 0.00, 0.08 ± 0.05, and 0.09 ± 0.07 logarithm of the minimum angle of resolution (logMAR) in the HM group, 0.02 ± 0.05, 0.15 ± 0.09, and 0.17 ± 0.09 logMAR in the PM group, respectively. In the PM group, mean MTD was 17.13 ± 6.79°. The MTD demonstrated a significant predictive effect on CDVA (regression coefficient: 0.005; P = 0.026) and DCNVA (regression coefficient: 0.015; P = 0.003). Trifocal IOL implantation yielded favorable visual outcomes in simple high myopic eyes, though results were comparatively poorer in PM cases. MTD was associated with the expected visual outcomes.
- Open Access
- 5 August 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-9
Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens
To research the accuracy of intraocular lens (IOL) calculation formulas and investigate the effect of anterior chamber depth (ACD) and lens thickness (LT) measured by swept-source optical coherence tomography biometer (IOLMaster 700) in patients with posterior chamber phakic IOL (PC-pIOL). Retrospective case series. The IOLMaster 700 biometer was used to measure axial length (AL) and anterior segment parameters. The traditional formulas (SRK/T, Holladay 1 and Haigis) with or without Wang-Koch (WK) AL adjustment, and new-generation formulas (Barret Universal II [BUII], Emmetropia Verifying Optical [EVO] v2.0, Kane, Pearl-DGS) were utilized in IOL power calculation. This study enrolled 24 eyes of 24 patients undergoing combined PC-pIOL removal and cataract surgery at Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China. The median absolute prediction error in ascending order was EVO 2.0 (0.33), Kane (0.35), SRK/T-WKmodified (0.42), Holladay 1-WKmodified (0.44), Haigis-WKC1 (0.46), Pearl-DGS (0.47), BUII (0.58), Haigis (0.75), SRK/T (0.79), and Holladay 1 (1.32). The root-mean-square absolute error in ascending order was Haigis-WKC1 (0.591), Holladay 1-WKmodified (0.622), SRK/T-WKmodified (0.623), EVO (0.673), Kane (0.678), Pearl-DGS (0.753), BUII (0.863), Haigis (1.061), SRK/T (1.188), and Holladay 1 (1.513). A detailed analysis of ACD and LT measurement error revealed negligible impact on refractive outcomes in BUII and EVO 2.0 when these parameters were incorporated or omitted in the formula calculation. The Kane, EVO 2.0, and traditional formulas with WK AL adjustment displayed high prediction accuracy. Furthermore, the ACD and LT measurement error does not exert a significant influence on the accuracy of IOL power calculation formulas in highly myopic eyes implanted with PC-pIOL.
- 5 August 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-9
Open AccessAccuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens
To research the accuracy of intraocular lens (IOL) calculation formulas and investigate the effect of anterior chamber depth (ACD) and lens thickness (LT) measured by swept-source optical coherence tomography biometer (IOLMaster 700) in patients with posterior chamber phakic IOL (PC-pIOL). Retrospective case series. The IOLMaster 700 biometer was used to measure axial length (AL) and anterior segment parameters. The traditional formulas (SRK/T, Holladay 1 and Haigis) with or without Wang-Koch (WK) AL adjustment, and new-generation formulas (Barret Universal II [BUII], Emmetropia Verifying Optical [EVO] v2.0, Kane, Pearl-DGS) were utilized in IOL power calculation. This study enrolled 24 eyes of 24 patients undergoing combined PC-pIOL removal and cataract surgery at Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China. The median absolute prediction error in ascending order was EVO 2.0 (0.33), Kane (0.35), SRK/T-WKmodified (0.42), Holladay 1-WKmodified (0.44), Haigis-WKC1 (0.46), Pearl-DGS (0.47), BUII (0.58), Haigis (0.75), SRK/T (0.79), and Holladay 1 (1.32). The root-mean-square absolute error in ascending order was Haigis-WKC1 (0.591), Holladay 1-WKmodified (0.622), SRK/T-WKmodified (0.623), EVO (0.673), Kane (0.678), Pearl-DGS (0.753), BUII (0.863), Haigis (1.061), SRK/T (1.188), and Holladay 1 (1.513). A detailed analysis of ACD and LT measurement error revealed negligible impact on refractive outcomes in BUII and EVO 2.0 when these parameters were incorporated or omitted in the formula calculation. The Kane, EVO 2.0, and traditional formulas with WK AL adjustment displayed high prediction accuracy. Furthermore, the ACD and LT measurement error does not exert a significant influence on the accuracy of IOL power calculation formulas in highly myopic eyes implanted with PC-pIOL.
- Open Access
- 16 January 2024
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10, 1247904
Application of three-dimensional visualization technology in phacoemulsification benefits the dry eye symptoms of patients after cataract surgery
Purpose: To investigate the effects of the three-dimension visualization system on dry eye in patients after cataract phacoemulsification.Methods: Seventy-one patients (104 eyes) were enrolled in this study and assigned to the conventional microscopic group (CM group) or three-dimension group (3D group). Ocular Surface Disease Index, The Schirmer I test (SIt), lipid layer thickness (LLT), noninvasive tear breakup time (NIBUT) and other factors associated with dry eye were recorded before and 1 week and 1 month after surgery. The operation time and intraoperative light intensity (ILI) were also recorded.Results: The ILI in the 3D group was significantly lower than that in the CM group (33% vs. 60%, p < 0.01). There was an interaction (group and time) effect for first NIBUT (NIBUT-F), average NIBUT (NIBUT-Ave), tear meniscus height (TMH) and the score of eye redness (Pinteraction < 0.05). The main effects of group on SIt, LLT, NIBUT-F, NIBUT-Ave and the score of eye redness were significant (Pgroup < 0.05). In the CM group, SIt, LLT, NIBUT-F, NIBUT-Ave, TMH were lower than those of the 3D group, the score of eye redness was higher than that of the 3D group at 1 week and 1 month after surgery (all p < 0.05). The changes in NIBUT-F and NIBUT-Ave between before surgery and 1 week after surgery showed negative correlations with ILI (p < 0.01).Conclusion: Compared with microscopic surgery, the 3D visualization system can provide better tear film stability for patients after cataract surgery.
- 16 January 2024
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10, 1247904
Open AccessApplication of three-dimensional visualization technology in phacoemulsification benefits the dry eye symptoms of patients after cataract surgery
Purpose: To investigate the effects of the three-dimension visualization system on dry eye in patients after cataract phacoemulsification.Methods: Seventy-one patients (104 eyes) were enrolled in this study and assigned to the conventional microscopic group (CM group) or three-dimension group (3D group). Ocular Surface Disease Index, The Schirmer I test (SIt), lipid layer thickness (LLT), noninvasive tear breakup time (NIBUT) and other factors associated with dry eye were recorded before and 1 week and 1 month after surgery. The operation time and intraoperative light intensity (ILI) were also recorded.Results: The ILI in the 3D group was significantly lower than that in the CM group (33% vs. 60%, p < 0.01). There was an interaction (group and time) effect for first NIBUT (NIBUT-F), average NIBUT (NIBUT-Ave), tear meniscus height (TMH) and the score of eye redness (Pinteraction < 0.05). The main effects of group on SIt, LLT, NIBUT-F, NIBUT-Ave and the score of eye redness were significant (Pgroup < 0.05). In the CM group, SIt, LLT, NIBUT-F, NIBUT-Ave, TMH were lower than those of the 3D group, the score of eye redness was higher than that of the 3D group at 1 week and 1 month after surgery (all p < 0.05). The changes in NIBUT-F and NIBUT-Ave between before surgery and 1 week after surgery showed negative correlations with ILI (p < 0.01).Conclusion: Compared with microscopic surgery, the 3D visualization system can provide better tear film stability for patients after cataract surgery.
- Open Access
- 1 January 2024
- Published by Wiley in Journal of Ophthalmology
- Vol. 2024 (1) , 5571802
Clinical Outcomes of a Trifocal Versus an Extended Depth of Field Intraocular Lens in Chinese Patients With Cataract: A Prospective Cohort Study
Purpose: To compare the standard outcomes between the PanOptix and Symfony multifocal intraocular lenses (MIOLs) in Chinese patients.Methods: This prospective observational cohort study enrolled patients with cataracts between April 2021 and December 2021 at Xiamen Eye Center Affiliated to Xiamen University. The patients were grouped in the PanOptix (TIOL group) and Symfony (EDF group) according to the IOLs implanted. Uncorrected distant, corrected distance, binocular uncorrected intermediate, and near visual acuity (UNVA), distance‐corrected intermediate and near VA (DCNVA) , defocus curve, spectacle independence, contrast sensitivity (CS), and visual disturbances were evaluated after 3 months.Results: Forty patients (80 eyes) were enrolled in the study (20/group). Three months after the operation, UNVA (0.13 ± 0.16) and DCNVA (0.08 ± 0.08) were better in the TIOL group than in the EDF group (0.22 ± 0.08 and 0.22 ± 0.08, respectively, p = 0.003 and p < 0.001, respectively). The TIOL group achieved a better‐than‐0.15‐logMAR VA from +0.5 D to −2.5 D (40 cm). VAs of the TIOL group from −1 D (100 cm) to −4 D (25 cm) were better than in the EDF group (p < 0.05). There were no significant differences in the intermediate and far vision outcomes (p > 0.05). Total near‐vision spectacle independence was higher in the TIOL group (80%) than in the EDF group (50%) (p = 0.039).Conclusion: Compared with EDF, TIOL leads to better near‐vision outcomes without significant differences for intermediate and distant vision outcomes.Trial Registration: ClinicalTrials.gov identifier: ChiCTR2100044558.
- 1 January 2024
- Published by Wiley in Journal of Ophthalmology
- Vol. 2024 (1) , 5571802
Open AccessClinical Outcomes of a Trifocal Versus an Extended Depth of Field Intraocular Lens in Chinese Patients With Cataract: A Prospective Cohort Study
Purpose: To compare the standard outcomes between the PanOptix and Symfony multifocal intraocular lenses (MIOLs) in Chinese patients.Methods: This prospective observational cohort study enrolled patients with cataracts between April 2021 and December 2021 at Xiamen Eye Center Affiliated to Xiamen University. The patients were grouped in the PanOptix (TIOL group) and Symfony (EDF group) according to the IOLs implanted. Uncorrected distant, corrected distance, binocular uncorrected intermediate, and near visual acuity (UNVA), distance‐corrected intermediate and near VA (DCNVA) , defocus curve, spectacle independence, contrast sensitivity (CS), and visual disturbances were evaluated after 3 months.Results: Forty patients (80 eyes) were enrolled in the study (20/group). Three months after the operation, UNVA (0.13 ± 0.16) and DCNVA (0.08 ± 0.08) were better in the TIOL group than in the EDF group (0.22 ± 0.08 and 0.22 ± 0.08, respectively, p = 0.003 and p < 0.001, respectively). The TIOL group achieved a better‐than‐0.15‐logMAR VA from +0.5 D to −2.5 D (40 cm). VAs of the TIOL group from −1 D (100 cm) to −4 D (25 cm) were better than in the EDF group (p < 0.05). There were no significant differences in the intermediate and far vision outcomes (p > 0.05). Total near‐vision spectacle independence was higher in the TIOL group (80%) than in the EDF group (50%) (p = 0.039).Conclusion: Compared with EDF, TIOL leads to better near‐vision outcomes without significant differences for intermediate and distant vision outcomes.Trial Registration: ClinicalTrials.gov identifier: ChiCTR2100044558.
- Open Access
- 24 August 2023
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10, 1241824
Accuracy of the FY-L formula in calculating intraocular lens power after small-incision lenticule extraction
Purpose: The study aimed to assess the accuracy of the FY-L formula in calculating intraocular lens (IOL) power after small-incision lenticule extraction (SMILE).Methods: For the post-SMILE IOL calculation of the same eye, the IOL power targeting the pre-SMILE eyes' lowest myopic refractive error was used. The FY-L formula, the Emmetropia Verifying Optical Formula (EVO-L), the Barrett True-K no history, and the Shammas-L, respectively, were used to calculate the predicted refractive error of target IOL power. A comparison was made between the change in spherical equivalent induced by SMILE (SMILE-Dif) and the variance between IOL-Dif (IOL-Induced Refractive Error) before and after SMILE. The prediction error (PE) was defined as SMILE-Dif minus IOL-Dif. The proportion of eyes with PEs within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D, the numerical and absolute prediction errors (PEs and AEs), and the median absolute error (MedAE) were compared.Results: In total, 80 eyes from 42 patients who underwent SMILE were included in the study. The FY-L formula generated the sample's lowest mean PE (0.06 ± 0.76 D), MAE (0.58 ± 0.50 D), and MedAE (0.47 D), respectively. The PEs in ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D comprised 28.8%, 46.3%, 70.0%, and 87.5%, respectively, for the FY-L formula. Compared to other formulas, the FY-L formula produced the highest value with PEs for the percentage of eyes in ±0.50 D, ±0.75 D, and ±1.00 D.Conclusion: This study demonstrates that the FY-L formula provides satisfactory outcomes in estimating the IOL power in the eyes after SMILE.
- 24 August 2023
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10, 1241824
Open AccessAccuracy of the FY-L formula in calculating intraocular lens power after small-incision lenticule extraction
Purpose: The study aimed to assess the accuracy of the FY-L formula in calculating intraocular lens (IOL) power after small-incision lenticule extraction (SMILE).Methods: For the post-SMILE IOL calculation of the same eye, the IOL power targeting the pre-SMILE eyes' lowest myopic refractive error was used. The FY-L formula, the Emmetropia Verifying Optical Formula (EVO-L), the Barrett True-K no history, and the Shammas-L, respectively, were used to calculate the predicted refractive error of target IOL power. A comparison was made between the change in spherical equivalent induced by SMILE (SMILE-Dif) and the variance between IOL-Dif (IOL-Induced Refractive Error) before and after SMILE. The prediction error (PE) was defined as SMILE-Dif minus IOL-Dif. The proportion of eyes with PEs within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D, the numerical and absolute prediction errors (PEs and AEs), and the median absolute error (MedAE) were compared.Results: In total, 80 eyes from 42 patients who underwent SMILE were included in the study. The FY-L formula generated the sample's lowest mean PE (0.06 ± 0.76 D), MAE (0.58 ± 0.50 D), and MedAE (0.47 D), respectively. The PEs in ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D comprised 28.8%, 46.3%, 70.0%, and 87.5%, respectively, for the FY-L formula. Compared to other formulas, the FY-L formula produced the highest value with PEs for the percentage of eyes in ±0.50 D, ±0.75 D, and ±1.00 D.Conclusion: This study demonstrates that the FY-L formula provides satisfactory outcomes in estimating the IOL power in the eyes after SMILE.
- Open Access
- 10 July 2023
- Published by Elsevier in Advances in Ophthalmology Practice and Research
- Vol. 3 (3) , 147-152
Stereopsis after bilateral implantation of Toric intraocular lenses in high myopic cataract patients with astigmatism
- 10 July 2023
- Published by Elsevier in Advances in Ophthalmology Practice and Research
- Vol. 3 (3) , 147-152
Open AccessStereopsis after bilateral implantation of Toric intraocular lenses in high myopic cataract patients with astigmatism
- Open Access
- 15 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Visual outcomes and subjective experience with three intraocular lenses based presbyopia correcting strategies in cataract patients
To compare the visual outcomes and subjective experience of three intraocular lenses (IOL) implant strategies. Retrospective comparative study. This study comprised patients who underwent phacoemulsification and bilateral implantation of extended depth of focus (EDOF) IOL (ZXR00; EDOF group), blended implantation of EDOF and bifocal IOL (ZXR00/ZLB00; blended group), and bilateral implantation of trifocal IOL (AT LISA tri 839MP; trifocal group). The outcomes included visual acuity (VA), visual defocus curve, contrast sensitivity, visual quality, quality of life, spectacle independence, and patient satisfaction. Follow-up was performed 3 months after the surgery. This study included 114 eyes of 57 patients (20 in EDOF group; 16 in blended group; 21 in trifocal group). Patients in the three groups had high quality of life, patient satisfaction, and good contrast sensitivity. The EDOF group had the worst near VA, but the visual quality was the best. The blended group had good VA and slight photic disturbance. The trifocal group obtained the best whole range of VA, but the photic disturbance was significantly severe than the EDOF group. Both the blended and trifocal groups achieved high spectacle independence, but some patients in the EDOF group need spectacle when dealing with close-range tasks.
- 15 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Open AccessVisual outcomes and subjective experience with three intraocular lenses based presbyopia correcting strategies in cataract patients
To compare the visual outcomes and subjective experience of three intraocular lenses (IOL) implant strategies. Retrospective comparative study. This study comprised patients who underwent phacoemulsification and bilateral implantation of extended depth of focus (EDOF) IOL (ZXR00; EDOF group), blended implantation of EDOF and bifocal IOL (ZXR00/ZLB00; blended group), and bilateral implantation of trifocal IOL (AT LISA tri 839MP; trifocal group). The outcomes included visual acuity (VA), visual defocus curve, contrast sensitivity, visual quality, quality of life, spectacle independence, and patient satisfaction. Follow-up was performed 3 months after the surgery. This study included 114 eyes of 57 patients (20 in EDOF group; 16 in blended group; 21 in trifocal group). Patients in the three groups had high quality of life, patient satisfaction, and good contrast sensitivity. The EDOF group had the worst near VA, but the visual quality was the best. The blended group had good VA and slight photic disturbance. The trifocal group obtained the best whole range of VA, but the photic disturbance was significantly severe than the EDOF group. Both the blended and trifocal groups achieved high spectacle independence, but some patients in the EDOF group need spectacle when dealing with close-range tasks.