Hai Peng
Research Subjects
Hai Peng has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Chengyi Hou
State Key Laboratory For Advanced Fiber Materials College of Materials Science and Engineering Donghua University Shanghai P. R. China
1 shared publication Ge Xu
Department of Orthopedics
1 shared publication- Heng Li
Department of Laboratory Medicine, Chongqing Center for Clinical Laboratory, Chongqing Academy of Medical Sciences, Chongqing General Hospital, School of Medicine, Chongqing University, Chongqing, China
1 shared publication Hong Zhang
Department of Laboratory Medicine, Chongqing General Hospital, School of Medicine
1 shared publicationJingzhi Wu
Department of Laboratory Medicine, Chongqing General Hospital, School of Medicine
1 shared publicationJunhui Zhang
Department of Geriatric Oncology and Department of Palliative Care
1 shared publication
Latest Publications
- 15 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (16) , 9000-9007
A Versatile Colorimetric Diagnostic Platform Based on Primer Exchange Reaction Cascades Driven Loop-Mediated Isothermal Amplification
The primer exchange reaction (PER), as a well-established and sophisticated isothermal nucleic acid amplification strategy, has been extensively employed to amplify various genetic biomarkers. However, the amplification efficiency of conventional PER is generally unsatisfactory due to its linear signal-amplifying mechanism. In this study, we developed a versatile colorimetric platform by rationally integrating Primer exchange reaction with efficient Loop-mediated isothermal amplification (LAMP), termed vcPeLa, for the rapid and sensitive detection of cancer-related biomarkers, such as microRNAs (miRNAs) and carcinoembryonic antigen (CEA). The PER cascade in the vcPeLa can be directly initiated by the target, resulting in the production of long single-stranded DNA products with repeated functional sections. These repeats in the product can serve as the template to produce a significant number of double stem-loop DNAs with the cooperation of DNA polymerase and hairpin structure primer probes. These DNAs are the primary starting materials for subsequent LAMP. A substantial quantity of pyrophosphate can be recognized by Cu2+-chelated pp Probe (pyrophosphate sensing probe). The Cu2+ is removed from the Cu2+-chelated pp Probe as a result of the formation of a complex between Cu2+ and pyrophosphate, which results in color changes. Consequently, the vcPeLa platform is feasible to detect 0.31 fM miRNA and 0.043 ng/mL CEA with high selectivity and stability without the requirement of introducing any additional reaction steps or sample transfer operations in comparison to conventional assays. Therefore, this facile and ultrasensitive vcPeLa platform provides a new promising tool for cancer diagnosis and biomarker screening.
- 15 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (16) , 9000-9007
A Versatile Colorimetric Diagnostic Platform Based on Primer Exchange Reaction Cascades Driven Loop-Mediated Isothermal Amplification
The primer exchange reaction (PER), as a well-established and sophisticated isothermal nucleic acid amplification strategy, has been extensively employed to amplify various genetic biomarkers. However, the amplification efficiency of conventional PER is generally unsatisfactory due to its linear signal-amplifying mechanism. In this study, we developed a versatile colorimetric platform by rationally integrating Primer exchange reaction with efficient Loop-mediated isothermal amplification (LAMP), termed vcPeLa, for the rapid and sensitive detection of cancer-related biomarkers, such as microRNAs (miRNAs) and carcinoembryonic antigen (CEA). The PER cascade in the vcPeLa can be directly initiated by the target, resulting in the production of long single-stranded DNA products with repeated functional sections. These repeats in the product can serve as the template to produce a significant number of double stem-loop DNAs with the cooperation of DNA polymerase and hairpin structure primer probes. These DNAs are the primary starting materials for subsequent LAMP. A substantial quantity of pyrophosphate can be recognized by Cu2+-chelated pp Probe (pyrophosphate sensing probe). The Cu2+ is removed from the Cu2+-chelated pp Probe as a result of the formation of a complex between Cu2+ and pyrophosphate, which results in color changes. Consequently, the vcPeLa platform is feasible to detect 0.31 fM miRNA and 0.043 ng/mL CEA with high selectivity and stability without the requirement of introducing any additional reaction steps or sample transfer operations in comparison to conventional assays. Therefore, this facile and ultrasensitive vcPeLa platform provides a new promising tool for cancer diagnosis and biomarker screening.
- 19 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (9) , 13279-13301
Smart Wearable Sensor Fuels Noninvasive Body Fluid Analysis
The advancements in wearable sensor technology have revolutionized noninvasive body fluid monitoring, offering new possibilities for continuous and real-time health assessment. By analyzing body fluids such as sweat, saliva, tears, and interstitial fluid, these technologies provide painless diagnostic alternatives for detecting biomarkers such as glucose, electrolytes, and metabolites. These sensors play a crucial role in early disease detection, chronic condition management, and personalized healthcare. Recent innovations in flexible electronics, microfluidic systems, and biosensing materials have significantly improved the accuracy, reliability, and integration of sensors into everyday textiles. Moreover, the convergence of artificial intelligence and big data analytics has enhanced the precision and personalization of health monitoring systems, transforming wearable sensors into powerful tools for health holographic inspection. Despite significant progress, challenges remain, including improving sensor stability in dynamic environments, achieving real-time data transmission, and covering a broader range of biomarkers. Future research directions focus on enhancing material sustainability through green synthesis, optimizing sampling techniques, and leveraging machine learning to further improve sensor performance. This Review highlights the transformative potential of wearable sensors in medical applications, aiming to bridge gaps in healthcare accessibility and elevate the standards of patient care through noninvasive continuous monitoring technologies.
- 19 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (9) , 13279-13301
Smart Wearable Sensor Fuels Noninvasive Body Fluid Analysis
The advancements in wearable sensor technology have revolutionized noninvasive body fluid monitoring, offering new possibilities for continuous and real-time health assessment. By analyzing body fluids such as sweat, saliva, tears, and interstitial fluid, these technologies provide painless diagnostic alternatives for detecting biomarkers such as glucose, electrolytes, and metabolites. These sensors play a crucial role in early disease detection, chronic condition management, and personalized healthcare. Recent innovations in flexible electronics, microfluidic systems, and biosensing materials have significantly improved the accuracy, reliability, and integration of sensors into everyday textiles. Moreover, the convergence of artificial intelligence and big data analytics has enhanced the precision and personalization of health monitoring systems, transforming wearable sensors into powerful tools for health holographic inspection. Despite significant progress, challenges remain, including improving sensor stability in dynamic environments, achieving real-time data transmission, and covering a broader range of biomarkers. Future research directions focus on enhancing material sustainability through green synthesis, optimizing sampling techniques, and leveraging machine learning to further improve sensor performance. This Review highlights the transformative potential of wearable sensors in medical applications, aiming to bridge gaps in healthcare accessibility and elevate the standards of patient care through noninvasive continuous monitoring technologies.