PJPhill Gu Jung

Phill Gu Jung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Phill Gu Jung has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Laser powder bed fusion parameter estimation with k-NN

    by Patrick Jung, Nathaniel DeVol, Christopher Saldaña, Katherine Fu

    Laser powder bed fusion (L-PBF) is a technique within additive manufacturing that uses a high power density laser to build parts from fused powdered metal alloy. This technology is well equipped to produce complex parts with otherwise impossible features, such as hidden voids or lattice structures. Alongside capability, reliability and quality are key characteristics considered when choosing a manufacturing method, and these are gaining attention as this method becomes more prevalent in industry. One main indicator of a stable L-PBF process is consistent melt pool geometry, and the properties of which are likely to determine the quality of the part produced. As computing power and sensing technologies become more advanced, this melt pool geometry could be studied in real time. This work addresses the challenge by leveraging a k-nearest neighbor (k-NN) model to identify key features within melt pool imagery and predict the energy density. The k-NN model was trained on data provided by the National Institute of Standards and Technology (NIST). Data preprocessing was performed on the images to extract features that were used in the k-NN model. This approach was used to accurately infer the energy density of unseen layers within the same part. The algorithm was subsequently tested with unique scan strategies and found to reasonably estimate the energy density of different parts. A fivefold cross validation found the algorithm to be consistently predicting the class of 91.4% of the in situ melt pool images.


  • Flexible Gd2O2S:Tb scintillators pixelated with polyethylene microstructures for digital x-ray image sensors

    by Im Deok Jung, Min Kook Cho, Sang Min Lee, Kong Myeong Bae, Phill Gu Jung, Chi Hoon Lee, Jae Min Lee, Seungman Yun, Ho Kyung Kim, Seong Sik Kim, et al.

    Flexible scintillators for digital x-ray image sensors were designed, fabricated and characterized. In these scintillaotrs, terbium-doped gadolinium oxysulfide (Gd2O2S:Tb) scintillator pixels were embedded into a polyethylene (PE) substrate. To evaluate the difference in the spatial resolution according to the pixel size, we designed three scintillators with pixels of different pitch sizes: 50 μm pitch size (P50), 100 μm pitch size (P100) and 200 μm pitch size (P200). Because of the high flexibility and good formability, polyethylene was used as the substrate of the scintillator. To fabricate nickel micromolds with high-aspect-ratio microstructures, two microfabrication techniques were employed: silicon dry-etching using a deep reactive ion etching (DRIE) process and nickel electroforming. The pixelated PE microstructures were fabricated by a hot embossing process. Because the solution-type Gd2O2S:Tb precursor can be handled at room temperature, Gd2O2S:Tb was used as the scintillator material. The measured sensitivities of the P50 and P100 models were, respectively, about 65% and 97% of that of the P200 model. The lower sensitivity values of the models with a small pitch size were due to two factors, such as the different pixel heights and the different fill factors. Because a scintillator with a small pixel size has a low fill factor, the sensitivity of the scintillator decreases as the pixel size decreases. The fill factors of the P50, P100 and P200 models were 36%, 49% and 56.25%, respectively. On the other hand, the spatial resolution of the scintillator increases as the pixel size decreases. Therefore, P50 gave the best spatial resolution among the designed models. The spatial frequency at 10% of the modulation transfer function (MTF) with P50 was 13.5 mm−1, while that with P200 was 10.0 mm−1. The resolution pattern and the tooth x-ray images obtained from a scintillator with a smaller pixel size was also clearer than that obtained from a scintillator with a larger pixel size. PE-based flexible Gd2O2S:Tb scintillators can be utilized directly in flexible x-ray image sensors. (Some figures in this article are in colour only in the electronic version)