Zhenxi Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhenxi Ma has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Liang Cai
School of Energy and Environment, Southeast University, Nanjing, Jiangsu, China
2 shared publications Changfei Tian
School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China
1 shared publication- Fengguo Liu
School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin, China
1 shared publication Houchang Gao
School of Energy and Environment, Southeast University, Nanjing, People’s Republic of China
1 shared publication- Huimin Wang
Southwest Jiaotong University
1 shared publication - Jian Liu
Southeast University
1 shared publication
Latest Publications
- 1 July 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (4)
The operation strategy of solar-hydrogen coupled integrated energy system considering power distribution of MFCS
High-temperature proton exchange membrane fuel cells have high efficiency, a simple water management system, high tolerance to impurities, and generate high-temperature heat, making them suitable for integrated energy systems (IES). Currently, research on the power allocation strategy of a multi-stack fuel cell system (MFCS) is mostly focused on transportation applications, emphasizing electrical efficiency and hydrogen consumption. However, MFCS often provides heating in IES, necessitating the consideration of thermal efficiency. Additionally, the lifespan of the stack is a major factor affecting the economic cost of the system and must also be incorporated into power allocation strategies. This paper aims to further promote the efficient application of MFCS within IES by proposing a solar-hydrogen coupled IES for office buildings. Considering the overall efficiency and stack lifespan, a segmented-optimal point operation allocation strategy is proposed. Furthermore, a coordinated operation strategy for the system's equipment is designed. MATLAB modeling is employed to configure the installed capacity of each equipment and calculate the operational results. The results show that the optimal number of stacks for this system is 5. Compared to an IES using a single-stack fuel cell system, MFCS-IES reduces the specific exergy cost by 9.15%, with a notable 56.0% decrease in stack replacement costs. During the operation of the stack, the thermal efficiency increased by an average of 13.27%, and the overall efficiency improved by 7.73%. This strategy avoids operation of the stack in low-power regions and reduces load fluctuations. As a result, the average degradation rate of the stack decreases by 50.44% in the MFCS, demonstrating significant performance enhancement.
- 1 July 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (4)
The operation strategy of solar-hydrogen coupled integrated energy system considering power distribution of MFCS
High-temperature proton exchange membrane fuel cells have high efficiency, a simple water management system, high tolerance to impurities, and generate high-temperature heat, making them suitable for integrated energy systems (IES). Currently, research on the power allocation strategy of a multi-stack fuel cell system (MFCS) is mostly focused on transportation applications, emphasizing electrical efficiency and hydrogen consumption. However, MFCS often provides heating in IES, necessitating the consideration of thermal efficiency. Additionally, the lifespan of the stack is a major factor affecting the economic cost of the system and must also be incorporated into power allocation strategies. This paper aims to further promote the efficient application of MFCS within IES by proposing a solar-hydrogen coupled IES for office buildings. Considering the overall efficiency and stack lifespan, a segmented-optimal point operation allocation strategy is proposed. Furthermore, a coordinated operation strategy for the system's equipment is designed. MATLAB modeling is employed to configure the installed capacity of each equipment and calculate the operational results. The results show that the optimal number of stacks for this system is 5. Compared to an IES using a single-stack fuel cell system, MFCS-IES reduces the specific exergy cost by 9.15%, with a notable 56.0% decrease in stack replacement costs. During the operation of the stack, the thermal efficiency increased by an average of 13.27%, and the overall efficiency improved by 7.73%. This strategy avoids operation of the stack in low-power regions and reduces load fluctuations. As a result, the average degradation rate of the stack decreases by 50.44% in the MFCS, demonstrating significant performance enhancement.
- 26 March 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 20 (15) , 1785-1799
Performance evaluation of proton exchange membrane fuel cell and air source heat pump system with energy storage for residential application
This paper combines the advantages of air source heat pumps and proton exchange membrane fuel cells, and analyses the dynamic performance, environmental benefits, and economic benefits of combined cooling, heating, and power (CCHP) systems combined with energy storage systems applied to residential buildings. The fuel cell voltage and heat model, air source heat pump (ASHP) model, and energy storage system model are developed in MATLAB. The results show that the problem of thermoelectric asynchrony and excess energy wastage can be solved by using the heat-following strategy with a battery and the electric-following strategy with a water tank. With the heat-following strategy in winter, the total thermodynamic efficiency of the system is 1.265, the carbon emission reduction is 6208.6 g, and the initial cost, operation cost, and maintenance cost are 6007$, 11.99$, and 300.35$, respectively. The efficiency of the system with the winter electric-following strategy is 1.284, the emission reduction is 6781.4 g, and the initial cost, operation cost, and maintenance cost are 7202.9$, 11.88$, and 360.14$, respectively. In summer with the electric-following strategy, the thermodynamic efficiency of the system is 1.514; the carbon reduction is 8,033.6 g. The initial cost, operation cost, and maintenance cost are 7,208.3$, 14.84$, and 360.42$.
- 26 March 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 20 (15) , 1785-1799
Performance evaluation of proton exchange membrane fuel cell and air source heat pump system with energy storage for residential application
This paper combines the advantages of air source heat pumps and proton exchange membrane fuel cells, and analyses the dynamic performance, environmental benefits, and economic benefits of combined cooling, heating, and power (CCHP) systems combined with energy storage systems applied to residential buildings. The fuel cell voltage and heat model, air source heat pump (ASHP) model, and energy storage system model are developed in MATLAB. The results show that the problem of thermoelectric asynchrony and excess energy wastage can be solved by using the heat-following strategy with a battery and the electric-following strategy with a water tank. With the heat-following strategy in winter, the total thermodynamic efficiency of the system is 1.265, the carbon emission reduction is 6208.6 g, and the initial cost, operation cost, and maintenance cost are 6007$, 11.99$, and 300.35$, respectively. The efficiency of the system with the winter electric-following strategy is 1.284, the emission reduction is 6781.4 g, and the initial cost, operation cost, and maintenance cost are 7202.9$, 11.88$, and 360.14$, respectively. In summer with the electric-following strategy, the thermodynamic efficiency of the system is 1.514; the carbon reduction is 8,033.6 g. The initial cost, operation cost, and maintenance cost are 7,208.3$, 14.84$, and 360.42$.
- 1 January 2021
- Published by Elsevier in International Journal of Refrigeration
- Vol. 121, 206-215
Research on waste heat recovery from gas engine for auxiliary heating: An emerging operation strategy to gas engine-driven heat pump
- 1 January 2021
- Published by Elsevier in International Journal of Refrigeration
- Vol. 121, 206-215
Research on waste heat recovery from gas engine for auxiliary heating: An emerging operation strategy to gas engine-driven heat pump