Yihua Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yihua Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dong Jiang
Huazhong University of Science and Technology
5 shared publications - Yixuan Shuai
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
5 shared publications - Jianfu Ding
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
4 shared publications - Mingqu Zhou
Huazhong University of Science and Technology
4 shared publications - Zicheng Liu
Key laboratory of power electronics and energy management, Ministry of Education of China, Huazhong University of Science and Technology, Wuhan, China
3 shared publications Haibo Sui
1 shared publication
Latest Publications
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Fault Diagnosis and Fault-Tolerant Method for Current Sensors in Active Magnetic Bearings Utilizing Multi-Current Sensor Information
Current sensors, as critical components in active magnetic bearing (AMB) systems, directly determine the accuracy and stability of rotor suspension. However, the large number of sensors required considerably degrades system reliability, while research on current sensor fault detection in AMBs remains scarce. To address this overlooked issue, this paper proposes a fault detection and fault-tolerant control strategy based on multi-sensor information fusion. A bus current sensor is introduced into the improved power amplifier topology to provide redundant information. Fault occurrence is identified by comparing sensor measurements at each switching cycle, and the faulty sensor is located through a modified modulation strategy. Redundant information is then utilized to extract fault features and compensate for offset, gain, and signal loss faults. The proposed strategy applies to both phase current sensors and the bus current sensor, and supports continuous detection and fault tolerance for offset and gain faults after correction, thereby enhancing measurement reliability and accuracy. Experimental validation on a five-degree-of-freedom AMB demonstrates that the proposed method can effectively detect and compensate current sensor faults, ensuring stable rotor suspension.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Fault Diagnosis and Fault-Tolerant Method for Current Sensors in Active Magnetic Bearings Utilizing Multi-Current Sensor Information
Current sensors, as critical components in active magnetic bearing (AMB) systems, directly determine the accuracy and stability of rotor suspension. However, the large number of sensors required considerably degrades system reliability, while research on current sensor fault detection in AMBs remains scarce. To address this overlooked issue, this paper proposes a fault detection and fault-tolerant control strategy based on multi-sensor information fusion. A bus current sensor is introduced into the improved power amplifier topology to provide redundant information. Fault occurrence is identified by comparing sensor measurements at each switching cycle, and the faulty sensor is located through a modified modulation strategy. Redundant information is then utilized to extract fault features and compensate for offset, gain, and signal loss faults. The proposed strategy applies to both phase current sensors and the bus current sensor, and supports continuous detection and fault tolerance for offset and gain faults after correction, thereby enhancing measurement reliability and accuracy. Experimental validation on a five-degree-of-freedom AMB demonstrates that the proposed method can effectively detect and compensate current sensor faults, ensuring stable rotor suspension.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 9267-9280
Zero Common-Mode Voltage Modulation Strategy for Three-Level Half-Bridge Neutral-Point-Clamped Topology Applied to Active Magnetic Bearings
Active magnetic bearing (AMB) systems serve as a key enabling technology for high-speed rotating machinery. As power ratings continue to rise, the dc-link voltage, phase current, and physical dimensions of the power converter and cabling also increase, which results in larger common-mode voltage swings and parasitic capacitive currents. Consequently, power–signal coupling issues, especially common-mode electromagnetic interference (CM EMI), become more severe and have attracted growing research attention in practical applications. In this article, we propose a zero common-mode voltage (ZCMV) modulation and control strategy combined with an active neutral-point voltage balancing scheme for the power electronic converter of a high-power AMB system. The proposed solution is implemented on a four-leg three-level half-bridge neutral-point-clamped topology, which is used to control a single-plane, two-degree-of-freedom AMB and can be readily extended to multi-degree-of-freedom magnetic bearing systems. The ZCMV modulation strategy significantly suppresses CM EMI and reduces interference with position sensors in the AMB control loop, thereby enhancing position control accuracy. Experimental results from a high-load-capacity AMB motor testbed demonstrate the effectiveness of the proposed approach.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 9267-9280
Zero Common-Mode Voltage Modulation Strategy for Three-Level Half-Bridge Neutral-Point-Clamped Topology Applied to Active Magnetic Bearings
Active magnetic bearing (AMB) systems serve as a key enabling technology for high-speed rotating machinery. As power ratings continue to rise, the dc-link voltage, phase current, and physical dimensions of the power converter and cabling also increase, which results in larger common-mode voltage swings and parasitic capacitive currents. Consequently, power–signal coupling issues, especially common-mode electromagnetic interference (CM EMI), become more severe and have attracted growing research attention in practical applications. In this article, we propose a zero common-mode voltage (ZCMV) modulation and control strategy combined with an active neutral-point voltage balancing scheme for the power electronic converter of a high-power AMB system. The proposed solution is implemented on a four-leg three-level half-bridge neutral-point-clamped topology, which is used to control a single-plane, two-degree-of-freedom AMB and can be readily extended to multi-degree-of-freedom magnetic bearing systems. The ZCMV modulation strategy significantly suppresses CM EMI and reduces interference with position sensors in the AMB control loop, thereby enhancing position control accuracy. Experimental results from a high-load-capacity AMB motor testbed demonstrate the effectiveness of the proposed approach.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 2029-2039
Novel Active Magnetic Bearing Power Amplifiers Based on the Single DC-Link Current Sensor
With the development of active magnetic bearings (AMBs), power electronics amplifiers have become a key area of research in electromechanical systems. Current sensors are connected in series with each coil in traditional power amplifiers, resulting in suboptimal utilization efficiency. This article proposes an innovative single-current-sensor architecture. The current sensor is positioned in the dc bus loop, allowing comprehensive current measurement across all coils. The proposed scheme introduces two key innovations: a switching-state-modulated current sampling strategy for coil current decoupling and a model predictive feedback current reconstruction strategy to overcome sampling frequency limitations. These strategies ensure that the performance of the single-current-sensor system is comparable to that of conventional configurations with multiple current sensors. For four-degree-of-freedom AMBs, the proposed scheme reduces the number of current sensors by 87.5% to lower costs and enhance the reliability of power amplifiers. The effectiveness of the proposed single-current-sensor scheme is validated through experimentation.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 2029-2039
Novel Active Magnetic Bearing Power Amplifiers Based on the Single DC-Link Current Sensor
With the development of active magnetic bearings (AMBs), power electronics amplifiers have become a key area of research in electromechanical systems. Current sensors are connected in series with each coil in traditional power amplifiers, resulting in suboptimal utilization efficiency. This article proposes an innovative single-current-sensor architecture. The current sensor is positioned in the dc bus loop, allowing comprehensive current measurement across all coils. The proposed scheme introduces two key innovations: a switching-state-modulated current sampling strategy for coil current decoupling and a model predictive feedback current reconstruction strategy to overcome sampling frequency limitations. These strategies ensure that the performance of the single-current-sensor system is comparable to that of conventional configurations with multiple current sensors. For four-degree-of-freedom AMBs, the proposed scheme reduces the number of current sensors by 87.5% to lower costs and enhance the reliability of power amplifiers. The effectiveness of the proposed single-current-sensor scheme is validated through experimentation.