Shengnan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shengnan Li has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Bin Zhang
School of Mechanical Engineering, Zhejiang University, China
1 shared publication- Bin Zhang
Zhejiang University
1 shared publication - Chunxiao Zhao
Zhejiang University
1 shared publication Hao Wang
School of Mechatronic Engineering, China University of Mining and Technology, China
1 shared publication- Haocen Hong
Zhejiang University
1 shared publication - Haoran Wan
Zhejiang University
1 shared publication
Latest Publications
- 1 November 2026
- Published by Springer Nature
- p. 724-745
Dynamic Characteristics and Performance Optimization of a Constant-Pressure Variable-Displacement Axial Piston Pump
- 1 November 2026
- Published by Springer Nature
- p. 724-745
Dynamic Characteristics and Performance Optimization of a Constant-Pressure Variable-Displacement Axial Piston Pump
- 29 March 2026
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
ADRC-based precision control of a novel dual-pilot water hydraulic digital valve
Intelligent fully mechanised mining faces impose high requirements on the straightness of scraper conveyors, which are essential for improving automation levels and operational safety in underground coal mines. However, motion control of scraper conveyors employs on/off electrohydraulic directional valves, making precise position control challenging. A novel high-pressure large-flow water hydraulic digital flow valve with a dual-pilot valve is proposed in this study to address the aforementioned issues. The pilot valve consists of double two-position three-way ball valves, which achieve independent control of load ports for the main spool. The main valve adopts a symmetric cylinder-type cone valve structure. First, a third-order integrator-type mathematical model of the flow valve is established through coordinate transformation. An active disturbance rejection control (ADRC) controller and an extended state observer designed to estimate and compensate for system uncertainties and disturbances are built for main spool displacement. The stability of the digital valve’s closed-loop control system is verified through inverse Lyapunov methods and disturbance theory. Second, the effects of ADRC parameters on step response performance are studied via simulation, and optimal control parameters are identified. Finally, a prototype of the flow valve is developed, and a corresponding test bench is constructed. Experimental results demonstrate that with the proposed control strategy, the 8-mm step response of the main spool achieves a delay time of 0.076 s, representing a 19.1% reduction compared with the delay time under the proportional–integral–derivative (PID) control algorithm. Moreover, the rise time is reduced to 0.146 s, showing a 50.5% improvement compared with that under the PID algorithm. The proposed system offers other remarkable practical advantages, including strong anti-disturbance capability and high tracking accuracy, which contribute directly to enhanced equipment reliability and operational safety in mining environments.
- 29 March 2026
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
ADRC-based precision control of a novel dual-pilot water hydraulic digital valve
Intelligent fully mechanised mining faces impose high requirements on the straightness of scraper conveyors, which are essential for improving automation levels and operational safety in underground coal mines. However, motion control of scraper conveyors employs on/off electrohydraulic directional valves, making precise position control challenging. A novel high-pressure large-flow water hydraulic digital flow valve with a dual-pilot valve is proposed in this study to address the aforementioned issues. The pilot valve consists of double two-position three-way ball valves, which achieve independent control of load ports for the main spool. The main valve adopts a symmetric cylinder-type cone valve structure. First, a third-order integrator-type mathematical model of the flow valve is established through coordinate transformation. An active disturbance rejection control (ADRC) controller and an extended state observer designed to estimate and compensate for system uncertainties and disturbances are built for main spool displacement. The stability of the digital valve’s closed-loop control system is verified through inverse Lyapunov methods and disturbance theory. Second, the effects of ADRC parameters on step response performance are studied via simulation, and optimal control parameters are identified. Finally, a prototype of the flow valve is developed, and a corresponding test bench is constructed. Experimental results demonstrate that with the proposed control strategy, the 8-mm step response of the main spool achieves a delay time of 0.076 s, representing a 19.1% reduction compared with the delay time under the proportional–integral–derivative (PID) control algorithm. Moreover, the rise time is reduced to 0.146 s, showing a 50.5% improvement compared with that under the PID algorithm. The proposed system offers other remarkable practical advantages, including strong anti-disturbance capability and high tracking accuracy, which contribute directly to enhanced equipment reliability and operational safety in mining environments.