Ricardo Perez-Lopez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ricardo Perez-Lopez has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Arturo Garcia-Perez
Department of Electronics Engineering, Engineering Division of the Campus Irapuato-Salamanca, University of Guanajuato, Salamanca, Mexico
1 shared publication - David Granados-Lieberman
ENAP-RG, CA-Fuentes Alternas y Calidad de la Energía Eléctrica, Departamento de Ingeniería Electromecánica, Tecnológico Nacional de México/ITS de Irapuato, Carretera Irapuato-Silao km 12.5, Colonia El Copal, Irapuato CP 36821, Mexico
1 shared publication - Guillermo Tapia-Tinoco
Department of Agricultural Engineering, University of Guanajuato, Highway Irapuato-Silao km 9, Irapuato, 36500, Guanajuato, Mexico
1 shared publication - Jesus Ignacio Lara-Perez
Electronic Engineering Department, University of Guanajuato, Highway Salamanca-Valle de Santiago km. 3.5+1.8, Salamanca, 36885, Guanajuato, Mexico
1 shared publication - Jonathan Cepeda-Negrete
Department of Agricultural Engineering, University of Guanajuato, Highway Irapuato-Silao km 9, Irapuato, 36500, Guanajuato, Mexico
1 shared publication
Latest Publications
- Open Access
- 1 April 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (8) , 085316
Optimal control of transactive electric systems integrating smart loads and distributed power generation
This study proposes an optimal control strategy for a transactive energy system integrated with the main supply grid. The power infrastructure of this transactive system includes an electrical microgrid integrated with renewable energy sources (RES), energy storage systems (ESS), and smart loads (SLs). Each SL comprises an electric spring (ES) in series with a noncritical load (NCL). The ES regulates the voltage and manages local demand, making it particularly suitable for microgrids with a high RES penetration. The load variations and stochastic nature of RES are modelled using time-varying profiles to facilitate scenarios that closely resemble real-world conditions. The control strategy uses a metaheuristic algorithm to coordinate the operation of SLs and ESS to minimise voltage fluctuations, reduce power losses, and optimise power exchange within the transactive system. Specifically, the Particle Swarm optimisation (PSO) algorithm is used and compared to the Grey Wolf Optimiser (GWO) and the Genetic algorithm (GA). The results show that PSO achieves significant improvements, reducing operating costs by 77.94%, voltage deviation by 50%, and active power losses by 14.54% compared to scenarios without ES support.
- 1 April 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (8) , 085316
Open AccessOptimal control of transactive electric systems integrating smart loads and distributed power generation
This study proposes an optimal control strategy for a transactive energy system integrated with the main supply grid. The power infrastructure of this transactive system includes an electrical microgrid integrated with renewable energy sources (RES), energy storage systems (ESS), and smart loads (SLs). Each SL comprises an electric spring (ES) in series with a noncritical load (NCL). The ES regulates the voltage and manages local demand, making it particularly suitable for microgrids with a high RES penetration. The load variations and stochastic nature of RES are modelled using time-varying profiles to facilitate scenarios that closely resemble real-world conditions. The control strategy uses a metaheuristic algorithm to coordinate the operation of SLs and ESS to minimise voltage fluctuations, reduce power losses, and optimise power exchange within the transactive system. Specifically, the Particle Swarm optimisation (PSO) algorithm is used and compared to the Grey Wolf Optimiser (GWO) and the Genetic algorithm (GA). The results show that PSO achieves significant improvements, reducing operating costs by 77.94%, voltage deviation by 50%, and active power losses by 14.54% compared to scenarios without ES support.