Sergio Fuselli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sergio Fuselli has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Marco De Felice
Environment and Health Department, Italian National Institute of Health, Viale Regina Elena 299, IT-00185 Rome, Italy
3 shared publications - Roberta Morlino
Environment and Health Department, Istituto Superiore di Sanità, 00161 Rome, Italy, Italy
3 shared publications - Luigi Turrio-Baldassarri
Istituto Superiore di Sanità (ISS)
2 shared publications Alessandro Piermattei
1 shared publication- Anna Santarsiero
Italian Natl Inst Hlth, Dept Environm & Hlth, Rome, Italy
1 shared publication Cristiana Zanetti
1 shared publication
Latest Publications
- Open Access
- 22 October 2010
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 7 (10) , 3792-3803
A Three Year Study on 14 VOCs at One Site in Rome: Levels, Seasonal Variations, Indoor/Outdoor Ratio and Temporal Trends
Fourteen volatile organic compounds (VOCs)—twelve hydrocarbons and two organochlorine compounds—were monitored both outdoors and indoors for three years at one site in Rome. Results showed that 118 out of 168 indoor seasonal mean values were higher than the corresponding outdoor concentrations. The most relevant source of outdoor hydrocarbons was automotive exhaust emissions. Due to the enforcement of various measures to protect health and the environment, outdoor levels of monoaromatic hydrocarbons decreased about ten fold over 15 years, and aliphatic hydrocarbons also decreased. With the decrease in these outdoor concentrations, indoor air sources are likely to be more relevant for indoor air exposures. Winter outdoor values for monoaromatic hydrocarbons were generally markedly higher than the summer ones. The gradual replacement of the current fleet of circulating cars with new cars complying with EURO 5 standards, further reducing hydrocarbon emissions, may possibly lead to an increase in the observed indoor/outdoor ratios. It is indeed more difficult to remove indoor sources, some of which are still unknown.
- 22 October 2010
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 7 (10) , 3792-3803
Open AccessA Three Year Study on 14 VOCs at One Site in Rome: Levels, Seasonal Variations, Indoor/Outdoor Ratio and Temporal Trends
Fourteen volatile organic compounds (VOCs)—twelve hydrocarbons and two organochlorine compounds—were monitored both outdoors and indoors for three years at one site in Rome. Results showed that 118 out of 168 indoor seasonal mean values were higher than the corresponding outdoor concentrations. The most relevant source of outdoor hydrocarbons was automotive exhaust emissions. Due to the enforcement of various measures to protect health and the environment, outdoor levels of monoaromatic hydrocarbons decreased about ten fold over 15 years, and aliphatic hydrocarbons also decreased. With the decrease in these outdoor concentrations, indoor air sources are likely to be more relevant for indoor air exposures. Winter outdoor values for monoaromatic hydrocarbons were generally markedly higher than the summer ones. The gradual replacement of the current fleet of circulating cars with new cars complying with EURO 5 standards, further reducing hydrocarbon emissions, may possibly lead to an increase in the observed indoor/outdoor ratios. It is indeed more difficult to remove indoor sources, some of which are still unknown.
- Open Access
- 22 October 2010
- Vol. 7 (10) , e1
Correction: Fuselli, et al. A Three Year Study on 14 VOCs at One Site in Rome: Levels, Seasonal Variations, Indoor / Outdoor Ratio and Temporal Trends. Int. J. Environ. Res. Public Health 2010, 7, 3792-3803.
[This corrects the article on p. 3792 in vol. 7.].
- 22 October 2010
- Vol. 7 (10) , e1
Open AccessCorrection: Fuselli, et al. A Three Year Study on 14 VOCs at One Site in Rome: Levels, Seasonal Variations, Indoor / Outdoor Ratio and Temporal Trends. Int. J. Environ. Res. Public Health 2010, 7, 3792-3803.
[This corrects the article on p. 3792 in vol. 7.].
- 1 January 2009
- Vol. 45 (1) , 87-98
Investigation of indoor air volatile organic compounds concentration levels in dental settings and some related methodological issues.
The assessment of indoor air volatile organic compounds (VOCs) concentration levels in dental settings has a big health relevance for the potentially massive occupational exposure to a lot of diverse contaminants. The comparison of the VOCs profile relative to indoor conditions and to the corresponding outdoor concentrations, as well as the discovery of possible correlations between specific dental activities and VOCs concentration variations are of utmost importance for offering a reliable characterization of risk for dentists and dental staff health. In this study we review the most relevant environmental studies addressing the VOCs contamination level in dental settings. We analyze the methodological problems this kind of study must face and we report preliminary results of an indoor air investigation, carried out at dental hospital in Italy, the "Ospedale odontoiatrico George Eastman" of Rome, in which general lines for the analysis of dental settings in environmental terms are sketched. The aim of this work is to identify the kind of problems a typical enclosed (non-industrial) environment indoor air investigation has to cope with by means of the analysis of a case study.
- 1 January 2009
- Vol. 45 (1) , 87-98
Investigation of indoor air volatile organic compounds concentration levels in dental settings and some related methodological issues.
The assessment of indoor air volatile organic compounds (VOCs) concentration levels in dental settings has a big health relevance for the potentially massive occupational exposure to a lot of diverse contaminants. The comparison of the VOCs profile relative to indoor conditions and to the corresponding outdoor concentrations, as well as the discovery of possible correlations between specific dental activities and VOCs concentration variations are of utmost importance for offering a reliable characterization of risk for dentists and dental staff health. In this study we review the most relevant environmental studies addressing the VOCs contamination level in dental settings. We analyze the methodological problems this kind of study must face and we report preliminary results of an indoor air investigation, carried out at dental hospital in Italy, the "Ospedale odontoiatrico George Eastman" of Rome, in which general lines for the analysis of dental settings in environmental terms are sketched. The aim of this work is to identify the kind of problems a typical enclosed (non-industrial) environment indoor air investigation has to cope with by means of the analysis of a case study.
- 1 January 2006
- Vol. 42 (3) , 365-8
[Formaldehyde in air of indoor and outdoor environments of urban area, relationships man's exposure].
This study presents the results of man's exposure to formaldehyde, carried out in indoor and outdoor environments in the city of Ferrara. The processes were obtained on average concentration measurements carried out for one month by indoor, outdoor and personal samplings. Concentration values obtained by personal samplings (PE) were compared to both outdoor and indoor values, the latter including domestic and working environments. The results showed that there was a significant difference between formaldeyde concentrations outdoor and PE (p = 0,03 < alpha = 0,05), while a significant difference was not found between indoor and PE. Indoor values (values as average of 38 samples) were 19,5 microg/m3, outdoor ones were 6,9 microg/m3 and PE 19,9 microg/m3. The average indoor value in domestic environments (20,7 microg/m3) was higher than the value found in working environments (17,9 microg/m3). Binary comparisons showed that indoor and outdoor, together with indoor and personal samplings, display the same variability of formaldehyde concentrations.
- 1 January 2006
- Vol. 42 (3) , 365-8
[Formaldehyde in air of indoor and outdoor environments of urban area, relationships man's exposure].
This study presents the results of man's exposure to formaldehyde, carried out in indoor and outdoor environments in the city of Ferrara. The processes were obtained on average concentration measurements carried out for one month by indoor, outdoor and personal samplings. Concentration values obtained by personal samplings (PE) were compared to both outdoor and indoor values, the latter including domestic and working environments. The results showed that there was a significant difference between formaldeyde concentrations outdoor and PE (p = 0,03 < alpha = 0,05), while a significant difference was not found between indoor and PE. Indoor values (values as average of 38 samples) were 19,5 microg/m3, outdoor ones were 6,9 microg/m3 and PE 19,9 microg/m3. The average indoor value in domestic environments (20,7 microg/m3) was higher than the value found in working environments (17,9 microg/m3). Binary comparisons showed that indoor and outdoor, together with indoor and personal samplings, display the same variability of formaldehyde concentrations.