Takao M. Kojima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Takao M. Kojima has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
H. Wollnik
New Mexico State University, Las Cruces, New Mexico 88001, USA
4 shared publications- Michiharu Wada
High Energy Accelerator Research Organization
4 shared publications - Peter Schury
High Energy Accelerator Research Organization
4 shared publications - Aiko Takamine
Graduate School of Science, Kyushu University, Nishi-ku, Fukuoka 819-0395, Japan
3 shared publications - D. S. Hou
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
3 shared publications - H. Ishiyama
RIKEN Nishina Center for Accelerator-Based Science
3 shared publications
Latest Publications
- 18 March 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 109 (3) , 035804
Mass measurements of neutron-rich nuclei constrain element abundancesAtomic masses of the neutron-rich isotopes , and have been measured with high precision and accuracy using the multi-reflection time-of-flight mass spectrograph at the RIBF facility. The masses of were measured for the first time and the mass uncertainties of and were significantly reduced from several hundred keV to below the 10 keV scale. Investigation of shell evolution and potential subshell closures are proceeded by analysis of two-neutron separation energy systematics. As a result of the precise mass measurements, no prominent change on the slope of the two-neutron separation energy beyond is observed in Se isotopes, indicating the subshell closure effect at of Se does not exist. Also, various leading mass models are compared with the measurements. The impact of the more precisely known data on -process nucleosynthesis calculations is investigated in light of these new mass measurements, showing a remarkable reduction of reaction-rate uncertainties.- 18 March 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 109 (3) , 035804
Mass measurements of neutron-rich nuclei constrain element abundancesAtomic masses of the neutron-rich isotopes , and have been measured with high precision and accuracy using the multi-reflection time-of-flight mass spectrograph at the RIBF facility. The masses of were measured for the first time and the mass uncertainties of and were significantly reduced from several hundred keV to below the 10 keV scale. Investigation of shell evolution and potential subshell closures are proceeded by analysis of two-neutron separation energy systematics. As a result of the precise mass measurements, no prominent change on the slope of the two-neutron separation energy beyond is observed in Se isotopes, indicating the subshell closure effect at of Se does not exist. Also, various leading mass models are compared with the measurements. The impact of the more precisely known data on -process nucleosynthesis calculations is investigated in light of these new mass measurements, showing a remarkable reduction of reaction-rate uncertainties.- 5 January 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 130 (1) , 012501
Study of the and Shell Gap for Ti and V by the First High-Precision Multireflection Time-of-Flight Mass Measurements at BigRIPS-SLOWRIThe atomic masses of , , and have been determined using the high-precision multireflection time-of-flight technique. The radioisotopes have been produced at RIKEN’s Radioactive Isotope Beam Factory (RIBF) and delivered to the novel designed gas cell and multireflection system, which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For and , the mass uncertainties have been reduced down to the order of 10 keV, shedding new light on the shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species and . With the new precision achieved, we reveal the nonexistence of the empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the and orbits and compare the results with conventional shell model calculations, which exclude the and the orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at .- 5 January 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 130 (1) , 012501
Study of the and Shell Gap for Ti and V by the First High-Precision Multireflection Time-of-Flight Mass Measurements at BigRIPS-SLOWRIThe atomic masses of , , and have been determined using the high-precision multireflection time-of-flight technique. The radioisotopes have been produced at RIKEN’s Radioactive Isotope Beam Factory (RIBF) and delivered to the novel designed gas cell and multireflection system, which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For and , the mass uncertainties have been reduced down to the order of 10 keV, shedding new light on the shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species and . With the new precision achieved, we reveal the nonexistence of the empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the and orbits and compare the results with conventional shell model calculations, which exclude the and the orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at .- Open Access
- 21 November 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1047, 167824
The new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN’s RIBF facility
- 21 November 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1047, 167824
Open AccessThe new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN’s RIBF facility
- 25 January 2018
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 51 (4) , 042001
Ion guiding in macro-size insulating capillaries: straight, tapered, and curved shapes
When keV energy ions are injected into a tilted insulating capillary, a certain fraction of the injected ions are transported through the tilt angle of the capillary. This ion guiding phenomenon is considered to be caused by a self-organizing charge distribution, where the inner wall of the capillary becomes charged by initial incoming ions. The charge distribution, which is formed, can guide following ions toward the exit of the capillary. Since the initial discovery of this effect, studies of ion guiding by insulating capillaries have been extended to various materials, and different sizes and shapes of capillaries. In recent years, some investigations of the guiding effect of macro-size curved capillaries have also been reported. In this review, relevant studies in a history of ion guiding in curved capillaries are discussed and future directions in this field are considered.
- 25 January 2018
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 51 (4) , 042001
Ion guiding in macro-size insulating capillaries: straight, tapered, and curved shapes
When keV energy ions are injected into a tilted insulating capillary, a certain fraction of the injected ions are transported through the tilt angle of the capillary. This ion guiding phenomenon is considered to be caused by a self-organizing charge distribution, where the inner wall of the capillary becomes charged by initial incoming ions. The charge distribution, which is formed, can guide following ions toward the exit of the capillary. Since the initial discovery of this effect, studies of ion guiding by insulating capillaries have been extended to various materials, and different sizes and shapes of capillaries. In recent years, some investigations of the guiding effect of macro-size curved capillaries have also been reported. In this review, relevant studies in a history of ion guiding in curved capillaries are discussed and future directions in this field are considered.
- 5 May 2009
- Published by AIP Publishing
- Vol. 1120 (1) , 109-113
Precision hyperfine structure spectroscopy of Be isotopes at SLOWRI prototype and prospects of SLOWRI at RIKEN
Precision atomic spectroscopy experiments for Be isotopes have been carried out at the prototype universal slow RI‐beam (SLOWRI) setup at RIKEN. Radioactive Be ions produced at 1 GeV were decelerated and thermlized in an RF‐carpet ion guide. The thermalized ions were transferred to an ion trap where laser cooling was used to reduce the ion energy to the order of Laser microwave double resonance spectroscopy was performed for the hyperfine structure measurements of trapped and laser cooled and ions. Measurements of the transition frequencies of ions are also in progress. These results are briefly discussed. Future prospects for expanding the capability of SLOWRI is also discussed.- 5 May 2009
- Published by AIP Publishing
- Vol. 1120 (1) , 109-113
Precision hyperfine structure spectroscopy of Be isotopes at SLOWRI prototype and prospects of SLOWRI at RIKEN
Precision atomic spectroscopy experiments for Be isotopes have been carried out at the prototype universal slow RI‐beam (SLOWRI) setup at RIKEN. Radioactive Be ions produced at 1 GeV were decelerated and thermlized in an RF‐carpet ion guide. The thermalized ions were transferred to an ion trap where laser cooling was used to reduce the ion energy to the order of Laser microwave double resonance spectroscopy was performed for the hyperfine structure measurements of trapped and laser cooled and ions. Measurements of the transition frequencies of ions are also in progress. These results are briefly discussed. Future prospects for expanding the capability of SLOWRI is also discussed.- 22 March 2008
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 266 (12-13) , 2762-2765
An optoelectronic device in bulk LiF with sub-micron periodic gratings fabricated by interference of 400nm femtosecond laser pulses
- 22 March 2008
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 266 (12-13) , 2762-2765
An optoelectronic device in bulk LiF with sub-micron periodic gratings fabricated by interference of 400nm femtosecond laser pulses
- Open Access
- 1 May 1998
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 5 (3) , 1058-1060
Experimental apparatus for the study of photoabsorption processes of multiply charged ions by synchrotron radiation
Photon–ion merged-beam apparatus using a compact ECR ion source and a high-brilliance light source has been designed for the study of photoabsorption processes of multiply charged ions. Photoion spectroscopy will be performed along isoelectronic, isonuclear and isoionic sequences. The main features of this apparatus are described.
- 1 May 1998
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 5 (3) , 1058-1060
Open AccessExperimental apparatus for the study of photoabsorption processes of multiply charged ions by synchrotron radiation
Photon–ion merged-beam apparatus using a compact ECR ion source and a high-brilliance light source has been designed for the study of photoabsorption processes of multiply charged ions. Photoion spectroscopy will be performed along isoelectronic, isonuclear and isoionic sequences. The main features of this apparatus are described.
- Open Access
- 14 November 1995
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 28 (21) , 4593-4606
Three-dimensional recoil-ion momentum analyses in 8.7 MeV O7+-He collisions
Using high-resolution recoil-ion momentum spectroscopy we have measured the differential cross sections of single-electron capture and target single-ionization processes for 8.7 MeV O7+-He collisions as functions of scattering angle. A transverse momentum resolution of +or-0.2 au, which corresponds to an angular resolution of about +or-1.5*10-6 rad for the projectile scattering angle, was obtained by intersecting a well collimated O7+ beam with a target of a supersonic He jet from a pre-cooled gas and by measuring the recoil-ion transverse momentum. For the single capture reaction, information on the n-value of the electron final state in O6+ (1snl) is obtained from the longitudinal momentum of the recoil ions. In pure single-electron capture, the dominant contributions to capture were found to be those from the n=4 and higher states, whereas single capture accompanied by the ionization of the second target electron mainly populates n=2 to n=4 states. Furthermore, the measured transverse momentum distribution differs significantly between pure single capture and capture with simultaneous ionization. The measured data for the pure capture process compare favourably with theoretical results based on a molecular-state expansion method. Other experimental data are discussed in terms of the classical overbarrier model.
- 14 November 1995
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 28 (21) , 4593-4606
Open AccessThree-dimensional recoil-ion momentum analyses in 8.7 MeV O7+-He collisions
Using high-resolution recoil-ion momentum spectroscopy we have measured the differential cross sections of single-electron capture and target single-ionization processes for 8.7 MeV O7+-He collisions as functions of scattering angle. A transverse momentum resolution of +or-0.2 au, which corresponds to an angular resolution of about +or-1.5*10-6 rad for the projectile scattering angle, was obtained by intersecting a well collimated O7+ beam with a target of a supersonic He jet from a pre-cooled gas and by measuring the recoil-ion transverse momentum. For the single capture reaction, information on the n-value of the electron final state in O6+ (1snl) is obtained from the longitudinal momentum of the recoil ions. In pure single-electron capture, the dominant contributions to capture were found to be those from the n=4 and higher states, whereas single capture accompanied by the ionization of the second target electron mainly populates n=2 to n=4 states. Furthermore, the measured transverse momentum distribution differs significantly between pure single capture and capture with simultaneous ionization. The measured data for the pure capture process compare favourably with theoretical results based on a molecular-state expansion method. Other experimental data are discussed in terms of the classical overbarrier model.
- 15 January 1992
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 61 (1) , 6-9
Ion Mobility Measurements of He+in He Gas at 4.4 K
- 15 January 1992
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 61 (1) , 6-9
Ion Mobility Measurements of He+in He Gas at 4.4 K