Alina Voda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alina Voda has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Gildas Besançon
Univ. Grenoble Alpes, CNRS, Grenoble INP - Institute of Engineering, GIPSA-Lab, 38000, Grenoble, France
15 shared publications - Guillaume Becq
Gipsa-lab, University Grenoble Alpes, CNRS, Grenoble, France
6 shared publications - Mariana Mulinari Pinheiro Machado
Univ. Grenoble Alpes, Grenoble INP GIPSA-lab,Grenoble,France
6 shared publications - Olivier David
Institut de Neuroscience des Systèmes, Aix Marseille University, Marseille, France
4 shared publications - Philippe Kahane
Univ. Grenoble Alpes, Inserm U1216, CHU Grenoble Alpes, Grenoble Institut Neurosciences, GIN, Grenoble, France
4 shared publications - Abdelfatah Charef
SP-LAB Laboratory of Signal Processing, University of Mentouri Constantine 1, Constantine, Algeria
2 shared publications
Latest Publications
- Open Access
- 3 June 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 125
Delineating the epileptogenic zone from ictal SEEG: A system identification and soft voting ensemble approach
- 3 June 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 125
Open AccessDelineating the epileptogenic zone from ictal SEEG: A system identification and soft voting ensemble approach
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Applications of SEEG brain-electrode interface modelling to electrical parameters identification and tissue classification
This paper inspects dynamical modelling for brain-electrode interface in the context of StereoElectroEncephaloGraphic (SEEG) recordings using electrodes directly implanted into brain tissue. Considering a physical-based non-integer-order transfer function modelling approach, it is first emphasized how it can be usable for tissue classification (between grey and white matters) near each SEEG contact. In addition, it is shown how the model parameters can also provide more insights on electrical properties in the areas where measurements are collected. Validating identification and classification results are finally presented for clinical data, the former providing estimates of resistivity and capacitivity-related coefficients, and the latter showing more than 70% of accuracy.
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Applications of SEEG brain-electrode interface modelling to electrical parameters identification and tissue classification
This paper inspects dynamical modelling for brain-electrode interface in the context of StereoElectroEncephaloGraphic (SEEG) recordings using electrodes directly implanted into brain tissue. Considering a physical-based non-integer-order transfer function modelling approach, it is first emphasized how it can be usable for tissue classification (between grey and white matters) near each SEEG contact. In addition, it is shown how the model parameters can also provide more insights on electrical properties in the areas where measurements are collected. Validating identification and classification results are finally presented for clinical data, the former providing estimates of resistivity and capacitivity-related coefficients, and the latter showing more than 70% of accuracy.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 440-445
System-Identification-Based Automatic Brain Tissue Classification for Stereoelectroencephalography
In the cases of drug-resistant epilepsy, patients might undergo resective surgery of the epileptic zone (EZ). The success of the surgery depends on the correct identification of the EZ and the eloquent cortex to be avoided. In both cases, the correct classification of the tissue where the measuring contacts are inserted is needed during the stereoelectroencephalography (SEEG). Most of the tissue classification procedures rely on imaging. In this paper a system identification based automatic classifier is proposed using previously proposed non-parametric and parametric methods for single contact tissue classification. By combining both identification methods, poorly classified contacts can be eliminated, and overall contact classification can be improved, especially for the parametric classifier. The proposed method can be either used in combination with imaging methods, or it could be used to help select contacts to be recorded during SEEG Investigation.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 440-445
System-Identification-Based Automatic Brain Tissue Classification for Stereoelectroencephalography
In the cases of drug-resistant epilepsy, patients might undergo resective surgery of the epileptic zone (EZ). The success of the surgery depends on the correct identification of the EZ and the eloquent cortex to be avoided. In both cases, the correct classification of the tissue where the measuring contacts are inserted is needed during the stereoelectroencephalography (SEEG). Most of the tissue classification procedures rely on imaging. In this paper a system identification based automatic classifier is proposed using previously proposed non-parametric and parametric methods for single contact tissue classification. By combining both identification methods, poorly classified contacts can be eliminated, and overall contact classification can be improved, especially for the parametric classifier. The proposed method can be either used in combination with imaging methods, or it could be used to help select contacts to be recorded during SEEG Investigation.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 576-581
Dynamic Modelling of the Brain-electrode Interface for Stereoelectroencephalography
The modelling of the brain-electrode interface has many useful applications whenever patients are implanted with intra-cranial electrodes. In general, extensive research has been performed using electrode impedance spectroscopy in cases of deep brain stimulation for patients suffering from motor disorders. The brain-electrode interface model is also useful when it comes to epileptic patients, not only for diagnosis purpose, artefact correction, but also potentially for brain tissue classification. However, for this latter application, the interface model has never been studied considering typical stereoelectroencephalography signals. In this scope, the aim of this paper is to propose a brain-electrode interface model adapted to be used considering only voltages recorded during pre-surgical investigations. Various models are discussed based on a previous study on a phantom EEG device, and compared to the expected dynamics between pairs of consecutive contacts also presented in a previous non-parametric transfer function study. From this, two new models are proposed: one based in monopolar derivation, and the other on bipolar derivation. The models are simulated, and identified for three pairs of contacts inserted in one patient. The model based on bipolar derivation had better results.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 576-581
Dynamic Modelling of the Brain-electrode Interface for Stereoelectroencephalography
The modelling of the brain-electrode interface has many useful applications whenever patients are implanted with intra-cranial electrodes. In general, extensive research has been performed using electrode impedance spectroscopy in cases of deep brain stimulation for patients suffering from motor disorders. The brain-electrode interface model is also useful when it comes to epileptic patients, not only for diagnosis purpose, artefact correction, but also potentially for brain tissue classification. However, for this latter application, the interface model has never been studied considering typical stereoelectroencephalography signals. In this scope, the aim of this paper is to propose a brain-electrode interface model adapted to be used considering only voltages recorded during pre-surgical investigations. Various models are discussed based on a previous study on a phantom EEG device, and compared to the expected dynamics between pairs of consecutive contacts also presented in a previous non-parametric transfer function study. From this, two new models are proposed: one based in monopolar derivation, and the other on bipolar derivation. The models are simulated, and identified for three pairs of contacts inserted in one patient. The model based on bipolar derivation had better results.
- Open Access
- 7 October 2021
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 365, 109375
Brain tissue classification from stereoelectroencephalographic recordings
- 7 October 2021
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 365, 109375
Open AccessBrain tissue classification from stereoelectroencephalographic recordings
- 14 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 29 (3) , 1075-1086
Observer-Based 3-D Control Enhancement for Topographic Imaging—Validation With an STM Prototype
This article proposes a control method using online state estimation techniques in order to enhance the capabilities of classical PI controllers as well as to improve the topographic imaging for an experimental scanning tunneling microscope-like device. In particular, a set of robust observers are designed following a recently proposed technique that takes advantage of control strategies in order to build such estimators. All three directional axes of such a subnanometric imaging device are controlled using the proposed method in order to obtain better images of a scanned surface. Real-time results for topographic imaging of a graphite sample are presented in order to illustrate the performances of the proposed method.
- 14 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 29 (3) , 1075-1086
Observer-Based 3-D Control Enhancement for Topographic Imaging—Validation With an STM Prototype
This article proposes a control method using online state estimation techniques in order to enhance the capabilities of classical PI controllers as well as to improve the topographic imaging for an experimental scanning tunneling microscope-like device. In particular, a set of robust observers are designed following a recently proposed technique that takes advantage of control strategies in order to build such estimators. All three directional axes of such a subnanometric imaging device are controlled using the proposed method in order to obtain better images of a scanned surface. Real-time results for topographic imaging of a graphite sample are presented in order to illustrate the performances of the proposed method.
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 8571-8576
Towards observer-based tunneling current calibration in an experimental STM device.
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 8571-8576
Towards observer-based tunneling current calibration in an experimental STM device.
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 15922-15927
New modeling results for an EEG measurement system with exciting and reading electrodes
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 15922-15927
New modeling results for an EEG measurement system with exciting and reading electrodes
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 120-125
Creep modeling for piezoelectric actuators using fractional order system of commensurate order
This paper focuses on the creep modelling for the piezoelectric actuators (PEAs) using fractional system of commensurate order. The proposed fractional system of commensurate order is derived from another fractional system of non commensurate order through an identification method based on the recursive least squares algorithm. The choice of the fractional system of commensurate order representation is due mainly to the ability to use this representation to implement the PEA using analogue circuits through rational function approximation of its irrational transfer function, to represent the PEA using a fractional order state space representation, to easily study the PEA's stability and to derive its closed form responses. The proposed PEA model has been validated in simulation and on an experimental set-up from Gipsa-lab.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 120-125
Creep modeling for piezoelectric actuators using fractional order system of commensurate order
This paper focuses on the creep modelling for the piezoelectric actuators (PEAs) using fractional system of commensurate order. The proposed fractional system of commensurate order is derived from another fractional system of non commensurate order through an identification method based on the recursive least squares algorithm. The choice of the fractional system of commensurate order representation is due mainly to the ability to use this representation to implement the PEA using analogue circuits through rational function approximation of its irrational transfer function, to represent the PEA using a fractional order state space representation, to easily study the PEA's stability and to derive its closed form responses. The proposed PEA model has been validated in simulation and on an experimental set-up from Gipsa-lab.
- Open Access
- 1 January 2017
- Published by INSTICC
- p. 559-566
Experiments and Analysis for Fractional Order Modelling of an EEG Recording Process
- 1 January 2017
- Published by INSTICC
- p. 559-566
Open AccessExperiments and Analysis for Fractional Order Modelling of an EEG Recording Process