WXWei Xu

Wei Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wei Xu has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Microscale and Nanoscale Electrophotonic Diagnostic Devices

    by Kaiyu Fu, Wei Xu, Jiayun Hu, Arielle Lopez, Paul W. Bohn

    Detecting and identifying infectious agents and potential pathogens in complex environments and characterizing their mode of action is a critical need. Traditional diagnostics have targeted a single characteristic (e.g., spectral response, surface receptor, mass, intrinsic conductivity, etc.). However, advances in detection technologies have identified emerging approaches in which multiple modes of action are combined to obtain enhanced performance characteristics. Particularly appealing in this regard, electrophotonic devices capable of coupling light to electron translocation have experienced rapid recent growth and offer significant advantages for diagnostics. In this review, we explore three specific promising approaches that combine electronics and photonics: (1) assays based on closed bipolar electrochemistry coupling electron transfer to color or fluorescence, (2) sensors based on localized surface plasmon resonances, and (3) emerging nanophotonics approaches, such as those based on zero-mode waveguides and metamaterials.


  • Electrochromic Sensor for Multiplex Detection of Metabolites Enabled by Closed Bipolar Electrode Coupling

    by Wei Xu, Kaiyu Fu, Paul W. Bohn

    Biosensors based on converting electrochemical signals into optical readouts are attractive candidates as low-cost, high-throughput sensor platforms. Here, we described a closed bipolar electrode (CBE)-based two-cell electrochromic device for sensing multiple metabolites, using the simultaneous detection of lactate, glucose, and uric acid as a model system. In the two-cell configuration, an analytical cell contains a redox mediator combined with a specific oxidase, e.g., lactate oxidase, glucose oxidase, or uricase, to form an electrochemical mediator–electrocatalyst pair that supports redox cycling. A closed bipolar electrode couples the electron transfer event in the analytical cell to an electrochromic reaction in a separate reporter cell, such that the magnitude of the color change is related to the concentration of metabolites in the analytical cell. To demonstrate multiplex operation, the CBE-based electrochromic detector is modified by integrating three sets of detection chemistries into a single device, in which simultaneous determination of glucose, lactate, and uric acid is demonstrated. Device sensitivity can be tuned by using reporter cells with different volumes. Furthermore, the analytical cell of this device can be fabricated as a disposable, paper-based carbon electrode without any pretreatment, demonstrating the potential to screen phenotypes that require multiple biomarkers in a point-of-care format.


  • A fast process development flow by applying design technology co-optimization

    by Yi-Chieh Chen, Shin-Shing Yeh, Tsong-Hua Ou, Hung-Yu Lin, Yung-Ching Mai, Lawrence Lin, Jun-Cheng Lai, Ya Chieh Lai, Wei Xu, Philippe Hurat

  • Closed bipolar electrode-enabled dual-cell electrochromic detectors for chemical sensing

    by Wei Xu, Kaiyu Fu, Chaoxiong Ma, Paul W. Bohn

    Bipolar electrodes (BPE) are electrically floating metallic elements placed in electrified fluids that enable the coupling of anodic and cathodic redox reactions at the opposite ends by electron transfer through the electrode. One particularly compelling application allows electron transfer reactions at one end of a closed BPE to be read out optically by inducing a redox-initiated change in the optical response function of a reporter system at the other end. Here, a BPE-enabled method for electrochemical sensing based on the electrochromic response of a methyl viologen (MV) reporter is developed, characterized, and rendered in a field-deployable format. BPE-enabled devices based on two thin-layer-cells of ITO and Pt were fabricated to couple an analytical reaction in one cell with an MV reporter reaction, producing a color change in the complementary cell. Using Fe(CN)6 3/4− as a model analyte, the electrochemically induced color change of MV was determined initially by measuring its absorbance via a CCD camera coupled to a microscope. Then, smartphone-based detection and RGB analysis were employed to further simplify the sensing scheme. Both methods produced a linear relationship between the analyte concentration, the quantity of MV generated, and the colorimetric response, yielding a limit of detection of 1.0 μM. Similar responses were observed in the detection of dopamine and acetaminophen. Further evolution of the device replaced the potentiostat with batteries to control potential, demonstrating the simplicity and portability of the device. Finally, the physical separation of the reporter and analytical cells renders the device competent to detect analytes in different (e.g. non-aqueous) phases, as demonstrated by using the electrochromic behavior of aqueous MV to detect ferrocene in acetonitrile in the analytical cell.


  • Ion Accumulation and Migration Effects on Redox Cycling in Nanopore Electrode Arrays at Low Ionic Strength

    by Chaoxiong Ma, Wei Xu, William R. A. Wichert, Paul W. Bohn

    Ion permselectivity can lead to accumulation in zero-dimensional nanopores, producing a significant increase in ion concentration, an effect which may be combined with unscreened ion migration to improve sensitivity in electrochemical measurements, as demonstrated by the enormous current amplification (∼2000-fold) previously observed in nanopore electrode arrays (NEA) in the absence of supporting electrolyte. Ionic strength is a key experimental factor that governs the magnitude of the additional current amplification (AFad) beyond simple redox cycling through both ion accumulation and ion migration effects. Separate contributions from ion accumulation and ion migration to the overall AFad were identified by studying NEAs with varying geometries, with larger AFad values being achieved in NEAs with smaller pores. In addition, larger AFad values were observed for Ru(NH3)63/2+ than for ferrocenium/ferrocene (Fc+/Fc) in aqueous solution, indicating that coupling efficiency in redox cycling can significantly affect AFad. While charged species are required to observe migration effects or ion accumulation, poising the top electrode at an oxidizing potential converts neutral species to cations, which can then exhibit current amplification similar to starting with the cation. The electrical double layer effect was also demonstrated for Fc/Fc+ in acetonitrile and 1,2-dichloroethane, producing AFad up to 100× at low ionic strength. The pronounced AFad effects demonstrate the advantage of coupling redox cycling with ion accumulation and migration effects for ultrasensitive electrochemical measurements.


  • Coupling of Independent Electrochemical Reactions and Fluorescence at Closed Bipolar Interdigitated Electrode Arrays

    by Wei Xu, Chaoxiong Ma, Paul W. Bohn

    Electrochemical reactions occurring at the opposite ends of bipolar electrodes (BPEs) are necessarily coupled, enabling electron transfer events at one end to be read out optically, for example, by coupling to fluorogenic reactions at the other end. To explore the potential of this technique for studying multiple redox events, arrays of parallel BPE interdigitated electrode arrays (IDEAs) were fabricated and integrated with separate analytical and reporter microfluidic channels, respectively, in a closed BPE configuration. The apparatus was initially evaluated employing Fe(CN)63/4− in the analytical channel coupled to weakly emissive resazurin and strongly emissive resorufin as the fluorogenic redox reporter pair. The device was then used to investigate a proton‐coupled electron transfer reaction, hydroquinone (QH2) oxidation, in structures with an integrated pH modulation electrode (PME). A pH‐sensitive dye, fluorescein, was co‐introduced into the analytical channel to monitor PME modulation of solution pH, and its coupling to QH2 oxidation, thereby permitting changes in solution pH, and consequently QH2 oxidation rate, to be monitored directly in the analytical channel and compared to the fluorescence in the reporter channel. In addition, diffusion of OH− generated at the PME produced a spatial pH profile that was visualized via fluorescein emission, and, because the oxidation of QH2 at each BPE is strongly dependent on the local pH, via the coupled fluorogenic reaction at the opposite pole of the corresponding BPE digit in the reporter channel. Thus, BPE IDEAs support the coupling of independent redox reactions and the use of fluorescence imaging to explore a diverse set of spatially varying electrochemical phenomena realized in a variety of electrochemical geometries.


  • On-demand in situ generation of oxygen in a nanofluidic embedded planar microband electrochemical reactor

    by Wei Xu, Erick Foster, Chaoxiong Ma, Paul W. Bohn

    In situ generation of reagents and their subsequent use downstream presents new opportunities to amplify the utility of nanofluidic devices by exploiting the confined geometry to address mass transport limitations on reaction kinetics and efficiency. Oxygen, an inherently valuable reactant, can be produced from electrolysis of water, a process that can be conveniently integrated within a nanofluidic system. Here, we construct and characterize a nanofluidic device consisting of a planar microband electrode embedded within a nanochannel for in situ electrochemical generation and optical monitoring of O2. Fluorescein, a dye with a pH-sensitive emission intensity, was used to monitor the spatiotemporal characteristics of the oxidation of H2O, using the co-produced H+. Application of anodic potentials at the nanochannel-embedded electrode results in a decrease in fluorescence intensity, which reflects the decreasing solution pH. A combination of fluorescence intensity and chronoamperometric response was used to quantitatively determine proton generation, and the H+/O2 stoichiometry was then used to determine the concentration of the O2 in the channel. Comparison of the experimental results to finite element simulations validates the use of fluorescein emission intensity to spectroscopically determine the local oxygen concentration in the nanochannel. By varying the applied potential, spatially averaged O2 concentrations ranging from 0.13 to 0.41 mM were generated. The results demonstrate a convenient route to in situ modulation of the dissolved O2 level in a nanofluidic device and the use of an optical probe to monitor its spatial and temporal distribution under flow conditions.


  • Nanofluidic structures for coupled sensing and remediation of toxins

    by K. Shaw, N. M. Contento, Wei Xu, P. W. Bohn

  • Sensing Small Molecule Interactions with Lipid Membranes by Local pH Modulation

    by Da Huang, Tao Zhao, Wei Xu, Tinglu Yang, Paul S. Cremer

    Herein, we utilized a label-free sensing platform based on pH modulation to detect the interactions between tetracaine, a positively charged small molecule used as a local anesthetic, and planar supported lipid bilayers (SLBs). The SLBs were patterned inside a flow cell, allowing for various concentrations of tetracaine to be introduced over the surface in a buffer solution. Studies with membranes containing POPC (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine) yielded an equilibrium dissociation constant value of Kd = 180 ± 47 μm for this small molecule–membrane interaction. Adding cholesterol to the SLBs decreased the affinity between tetracaine and the bilayers, while this interaction tightened when POPE (1-hexadecanoyl-2-(9-Z-octadecenoyl)-sn-glycero-3-phosphoethanolamine) was added. Studies were also conducted with three negatively charged membrane lipids, POPG (1-palmitoyl-2-oleoyl-sn-glycero-3-phospho-(1′-rac-glycerol) (sodium salt)), POPS (1-palmitoyl-2-oleoyl-sn-glycero-3-phospho-l-serine (sodium salt)), and ganglioside GM1. All three measurements gave rise to a similar tightening of the apparent Kd value compared with pure POPC membranes. The lack of chemical specificity with the identity of the negatively charged lipid indicated that the tightening was largely electrostatic. Through a direct comparison with ITC measurements, it was found that the pH modulation sensor platform offers a facile, inexpensive, highly sensitive, and rapid method for the detection of interactions between putative drug candidates and lipid bilayers. As such, this technique may potentially be exploited as a screen for drug development and analysis.