Alejandro Allepuz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alejandro Allepuz has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Mireia Espallargues
Department of Health, Catalan Agency for Quality and Healthcare Assessment; Catalan Health Service, Barcelona, Spain; CIBER de Epidemiología y Salud Pública (CIBERESP), Spain
7 shared publicationsM. Espallargues
4 shared publicationsO. Martínez
3 shared publicationsAntonio Escobar
2 shared publications- Antonio Escobar
Universidad Nacional Autónoma de Nicaragua, Managua
2 shared publications - Carlota Las Hayas
Department of Medicine Faculty of Health Sciences, University of Deusto Bilbao Spain
2 shared publications
Latest Publications
- 1 March 2014
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 29 (3) , 484-490
Joint Registries as Continuous Surveillance Systems: The Experience of the Catalan Arthroplasty Register (RACat)
- 1 March 2014
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 29 (3) , 484-490
Joint Registries as Continuous Surveillance Systems: The Experience of the Catalan Arthroplasty Register (RACat)
- 1 July 2013
- Published by Elsevier in Revista Española de Cirugía Ortopédica y Traumatología
- Vol. 57 (4) , 254-262
Factores relacionados con la calidad de vida al año de la artroplastia total de cadera y rodilla: estudio multicéntrico en Cataluña
- 1 July 2013
- Published by Elsevier in Revista Española de Cirugía Ortopédica y Traumatología
- Vol. 57 (4) , 254-262
Factores relacionados con la calidad de vida al año de la artroplastia total de cadera y rodilla: estudio multicéntrico en Cataluña
- 1 January 2013
- Published by Elsevier in Revista Española de Cirugía Ortopédica y Traumatología
- Vol. 57 (1) , 27-37
Los registros de artroplastias como sistemas de vigilancia poscomercialización: el Registro de Artroplastias de Cataluña
- 1 January 2013
- Published by Elsevier in Revista Española de Cirugía Ortopédica y Traumatología
- Vol. 57 (1) , 27-37
Los registros de artroplastias como sistemas de vigilancia poscomercialización: el Registro de Artroplastias de Cataluña
- 1 September 2012
- Published by Elsevier in Atencion Primaria
- Vol. 44 (9) , 568-569
Coordinación entre niveles asistenciales: ¿qué priorizan los profesionales?
- 1 September 2012
- Published by Elsevier in Atencion Primaria
- Vol. 44 (9) , 568-569
Coordinación entre niveles asistenciales: ¿qué priorizan los profesionales?
- Open Access
- 29 February 2012
- Published by Elsevier in Gaceta Sanitaria
- Vol. 26 (1) , 58-64
Eficiencia en la prescripción de medicamentos: impacto de un programa de intercambio terapéutico
- 29 February 2012
- Published by Elsevier in Gaceta Sanitaria
- Vol. 26 (1) , 58-64
Open AccessEficiencia en la prescripción de medicamentos: impacto de un programa de intercambio terapéutico
- 27 August 2010
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 17 (1) , 18-25
Relationship between total hip replacement appropriateness and surgical priority instruments
Variability in indications for total hip replacement (THR) and unequal waiting times may limit health care access. To analyse the relationship between appropriateness and previously developed surgical priority instruments. Multicentre cross-validation study of patients placed on the waiting list for THR. Information on surgical priority, surgeons' evaluation of priority through a visual analogue scale (VAS) and health-related quality of life (HRQOL) (Health Utilities Index mark 3, EQ-5D, Western Ontario McMaster Osteoarthritic Index) was collected. THR indications were considered appropriate, uncertain or inappropriate according to appropriateness criteria. Statistical differences and clinically important differences in surgical priority, VAS and HRQOL between appropriateness categories were analysed with the Mann-Whitney U-test and effect size (ES), respectively. Surgical priority score's ability to discriminate appropriate and inappropriate indications was evaluated through the area under the receiver-operating characteristic curve (AUC) and its 95% confidence interval (95% CI). 49.4% (87) of the THR indications were deemed appropriate, 39.8% (70) uncertain and 10.8% (19) inappropriate. Differences in surgical priority score, VAS and HRQOL between appropriateness categories were statistically significant. Clinically important differences were generally small (ES, 0.2-0.5) between inappropriate and uncertain, moderate (ES, 0.5-0.8) between uncertain and appropriate, and large (ES > 0.8) between inappropriate and appropriate categories. The AUC to discriminate appropriate and inappropriate indications was 0.97 (95% CI: 0.96-0.99) and 0.90 (95% CI: 0.83-0.97), respectively. The relationship between the surgical priority and appropriateness instruments reinforces their validity and could improve waiting list management by establishing maximum waiting periods based on patients' characteristics.
- 27 August 2010
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 17 (1) , 18-25
Relationship between total hip replacement appropriateness and surgical priority instruments
Variability in indications for total hip replacement (THR) and unequal waiting times may limit health care access. To analyse the relationship between appropriateness and previously developed surgical priority instruments. Multicentre cross-validation study of patients placed on the waiting list for THR. Information on surgical priority, surgeons' evaluation of priority through a visual analogue scale (VAS) and health-related quality of life (HRQOL) (Health Utilities Index mark 3, EQ-5D, Western Ontario McMaster Osteoarthritic Index) was collected. THR indications were considered appropriate, uncertain or inappropriate according to appropriateness criteria. Statistical differences and clinically important differences in surgical priority, VAS and HRQOL between appropriateness categories were analysed with the Mann-Whitney U-test and effect size (ES), respectively. Surgical priority score's ability to discriminate appropriate and inappropriate indications was evaluated through the area under the receiver-operating characteristic curve (AUC) and its 95% confidence interval (95% CI). 49.4% (87) of the THR indications were deemed appropriate, 39.8% (70) uncertain and 10.8% (19) inappropriate. Differences in surgical priority score, VAS and HRQOL between appropriateness categories were statistically significant. Clinically important differences were generally small (ES, 0.2-0.5) between inappropriate and uncertain, moderate (ES, 0.5-0.8) between uncertain and appropriate, and large (ES > 0.8) between inappropriate and appropriate categories. The AUC to discriminate appropriate and inappropriate indications was 0.97 (95% CI: 0.96-0.99) and 0.90 (95% CI: 0.83-0.97), respectively. The relationship between the surgical priority and appropriateness instruments reinforces their validity and could improve waiting list management by establishing maximum waiting periods based on patients' characteristics.
- 11 June 2010
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 16 (5) , 940-946
Different hip and knee priority score systems: are they good for the same thing?
The aim of the present study was to compare two priority tools used for joint replacement for patients on waiting lists, which use two different methods. Two prioritization tools developed and validated by different methodologies were used on the same cohort of patients. The first, an IRYSS hip and knee priority score (IHKPS) developed by RAND method, was applied while patients were on the waiting list. The other, a Catalonia hip-knee priority score (CHKPS) developed by conjoint analysis, was adapted and applied retrospectively. In addition, all patients fulfilled pre-intervention the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Correlation between them was studied by Pearson correlation coefficient (r). Agreement was analysed by means of intra-class correlation coefficient (ICC), Kendall coefficient and Cohern kappa. The relationship between IHKPS, CHKPS and baseline WOMAC scores by r coefficient was studied. The sample consisted of 774 consecutive patients. Pearson correlation coefficient between IHKPS and CHKPS was 0.79. The agreement study showed that ICC was 0.74, Kendall coefficient 0.86 and kappa 0.66. Finally, correlation between CHKPS and baseline WOMAC ranged from 0.43 to 0.64. The results according to the relationship between IHKPS and WOMAC ranged from 0.50 to 0.74. Results support the hypothesis that if the final objective of the prioritization tools is to organize and sort patients on the waiting list, although they use different methodologies, the results are similar.
- 11 June 2010
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 16 (5) , 940-946
Different hip and knee priority score systems: are they good for the same thing?
The aim of the present study was to compare two priority tools used for joint replacement for patients on waiting lists, which use two different methods. Two prioritization tools developed and validated by different methodologies were used on the same cohort of patients. The first, an IRYSS hip and knee priority score (IHKPS) developed by RAND method, was applied while patients were on the waiting list. The other, a Catalonia hip-knee priority score (CHKPS) developed by conjoint analysis, was adapted and applied retrospectively. In addition, all patients fulfilled pre-intervention the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Correlation between them was studied by Pearson correlation coefficient (r). Agreement was analysed by means of intra-class correlation coefficient (ICC), Kendall coefficient and Cohern kappa. The relationship between IHKPS, CHKPS and baseline WOMAC scores by r coefficient was studied. The sample consisted of 774 consecutive patients. Pearson correlation coefficient between IHKPS and CHKPS was 0.79. The agreement study showed that ICC was 0.74, Kendall coefficient 0.86 and kappa 0.66. Finally, correlation between CHKPS and baseline WOMAC ranged from 0.43 to 0.64. The results according to the relationship between IHKPS and WOMAC ranged from 0.50 to 0.74. Results support the hypothesis that if the final objective of the prioritization tools is to organize and sort patients on the waiting list, although they use different methodologies, the results are similar.
- 1 January 2010
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 45 (2) , 125-131
Comparison of 3 systems for assigning priority to patients on waiting lists for cataract extraction
- 1 January 2010
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 45 (2) , 125-131
Comparison of 3 systems for assigning priority to patients on waiting lists for cataract extraction
- 1 January 2010
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 45 (2) , e1-e7
Potential for 2 priority systems to be used as appropriateness of indication tools for cataract surgery
- 1 January 2010
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 45 (2) , e1-e7
Potential for 2 priority systems to be used as appropriateness of indication tools for cataract surgery
- 31 October 2009
- Published by Elsevier in Revista de Calidad Asistencial
- Vol. 24 (5) , 185-191
Criterios para priorizar a pacientes en lista de espera para procedimientos quirúrgicos en el Sistema Nacional de Salud
- 31 October 2009
- Published by Elsevier in Revista de Calidad Asistencial
- Vol. 24 (5) , 185-191
Criterios para priorizar a pacientes en lista de espera para procedimientos quirúrgicos en el Sistema Nacional de Salud