Jun Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jun Tan has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Godley
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
2 shared publications - Keith M. Furutani
Radiation Oncology, Mayo Clinic Florida, 4500 San Pablo Rd S, Jacksonville, Florida, 32224, UNITED STATES
2 shared publications Xiaoying Liang
Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL 32224, USA
2 shared publications- Adam P. Dicker
Thomas Jefferson University, Philadelphia, PA 19107, USA
1 shared publication - Alessio Parisi
Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, USA
1 shared publication Arnold Pompos
Department of Radiation Oncology, University of Texas- Southwestern Medical Center, Dallas, USA
1 shared publication
Latest Publications
- Open Access
- 7 February 2026
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 37, 100383
Simulation and optimization of treatment schedule for multi-gantry heavy ion therapy
- 7 February 2026
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 37, 100383
Open AccessSimulation and optimization of treatment schedule for multi-gantry heavy ion therapy
- 1 August 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (15) , 155009
Pioneering MCF MKM RBE-weighted dose calculation for carbon ion radiotherapy: development of a pencil beam algorithm and validation against Monte Carlo simulation on clinical CT data
Objective. This study aims to develop and validate a pencil beam (PB) algorithm for computing Mayo Clinic Florida microdosimetric kinetic model (MCF MKM)-based relative biological effectiveness (RBE) weighted doses in carbon-ion radiotherapy (CIRT), and to compare its accuracy and efficiency against Monte Carlo (MC) simulations using real patient computed tomography (CT) data. Approach. A PB algorithm was implemented to calculate both physical and microdosimetric parameters—using the abridged microdosimetry distribution methodology (AMDM)—for the MCF MKM model, and subsequently the RBE-weighted dose. Four clinical cases (brain, head and neck, lung and prostate) were planned in-house and computed using the PB algorithm and tool for particle simulation (TOPAS) MC simulations. Dose-volume histograms (DVHs), dose profiles, gamma analysis, and computational times were compared. Monochromatic and polychromatic AMDM kernels were also evaluated to assess any impact on RBE dose distributions. Main results. Except for the lung case, the PB algorithm showed strong agreement with TOPAS MC simulations, with gamma passing rates over 98% at 3%/3 mm and around 90% at 2%/2 mm for the other three cases. DVHs and dose profiles also closely matched. In the lung case, agreement was lower—87.6% at 3%/3 mm and 77.1% at 2%/2 mm—due to PB’s limitations in modeling Coulomb scattering in heterogeneous lung tissue. Still, PB calculations were completed in minutes, highlighting its potential for fast, clinically viable RBE dose evaluation. Significance. This study presents the first complete demonstration of an MCF MKM-based RBE dose calculation using a PB algorithm on actual patient CT data, providing a robust balance between accuracy and computational efficiency. Although limitations in PB modeling may introduce larger discrepancies in highly heterogeneous anatomical regions and sites, the overall performance and speed underscore the method’s viability for routine clinical CIRT planning.
- 1 August 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (15) , 155009
Pioneering MCF MKM RBE-weighted dose calculation for carbon ion radiotherapy: development of a pencil beam algorithm and validation against Monte Carlo simulation on clinical CT data
Objective. This study aims to develop and validate a pencil beam (PB) algorithm for computing Mayo Clinic Florida microdosimetric kinetic model (MCF MKM)-based relative biological effectiveness (RBE) weighted doses in carbon-ion radiotherapy (CIRT), and to compare its accuracy and efficiency against Monte Carlo (MC) simulations using real patient computed tomography (CT) data. Approach. A PB algorithm was implemented to calculate both physical and microdosimetric parameters—using the abridged microdosimetry distribution methodology (AMDM)—for the MCF MKM model, and subsequently the RBE-weighted dose. Four clinical cases (brain, head and neck, lung and prostate) were planned in-house and computed using the PB algorithm and tool for particle simulation (TOPAS) MC simulations. Dose-volume histograms (DVHs), dose profiles, gamma analysis, and computational times were compared. Monochromatic and polychromatic AMDM kernels were also evaluated to assess any impact on RBE dose distributions. Main results. Except for the lung case, the PB algorithm showed strong agreement with TOPAS MC simulations, with gamma passing rates over 98% at 3%/3 mm and around 90% at 2%/2 mm for the other three cases. DVHs and dose profiles also closely matched. In the lung case, agreement was lower—87.6% at 3%/3 mm and 77.1% at 2%/2 mm—due to PB’s limitations in modeling Coulomb scattering in heterogeneous lung tissue. Still, PB calculations were completed in minutes, highlighting its potential for fast, clinically viable RBE dose evaluation. Significance. This study presents the first complete demonstration of an MCF MKM-based RBE dose calculation using a PB algorithm on actual patient CT data, providing a robust balance between accuracy and computational efficiency. Although limitations in PB modeling may introduce larger discrepancies in highly heterogeneous anatomical regions and sites, the overall performance and speed underscore the method’s viability for routine clinical CIRT planning.
- Open Access
- 10 April 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 26, 100438
Evaluation of fan-beam kilovoltage computed tomography image quality on a novel biological-guided radiotherapy platform
- 10 April 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 26, 100438
Open AccessEvaluation of fan-beam kilovoltage computed tomography image quality on a novel biological-guided radiotherapy platform
- Open Access
- 8 December 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (1) , 015005
Machine characterization and central axis depth dose data of a superficial x-ray radiotherapy unit
Objectives. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy, Methods. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25, Results. The x-ray unit’s mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (2 collimator was (−0.7 ± 1.0)%, Conclusions. This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements, Advances in knowledge. This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted.
- 8 December 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (1) , 015005
Open AccessMachine characterization and central axis depth dose data of a superficial x-ray radiotherapy unit
Objectives. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy, Methods. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25, Results. The x-ray unit’s mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (2 collimator was (−0.7 ± 1.0)%, Conclusions. This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements, Advances in knowledge. This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted.
- Open Access
- 1 October 2017
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 99 (2) , E649
3D printer-assisted Soft Silicone Compensators for Electron Modulated Radiotherapy
- 1 October 2017
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 99 (2) , E649
Open Access3D printer-assisted Soft Silicone Compensators for Electron Modulated Radiotherapy
- Open Access
- 1 June 2015
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 92 (2) , 228-235
Quantifying Unnecessary Normal Tissue Complication Risks due to Suboptimal Planning: A Secondary Study of RTOG 0126
- 1 June 2015
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 92 (2) , 228-235
Open AccessQuantifying Unnecessary Normal Tissue Complication Risks due to Suboptimal Planning: A Secondary Study of RTOG 0126